| Plan Review Stops For Permit 13120518 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2013-12-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-12-27 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-12-27 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2013-12-27 15:48:59 | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | | | 1) SHEET LS-2 RED LINED, TO KEEP EXIT LIGHT AT | | | STAIRWELL 4.2, I SPOKE WITH THE DESIGNER OF RECORD TED | | | DAVIS ABOUT THIS HE WAS OK WITH THE RED LINING TO KEEP | | | THE EXIT LIGHT. | | | | | | 2) A REVISION IS REQUIRED, NO PRODUCT APPROVALS WERE | | | SUBMITTED, PRESSURES ARE OK. WE WILL NEED PRODUCT | | | APPROVALS FOR STOREFRONT GLAZING, EXTERIOR GLAZED DOORS | | | WITH PANIC HARDWARE. 2010 FBC-B 1008.1.10 REQUIRES | | | PANIC HARDWARE WITH AN ASSEMBLY OCUPANCY OVER 50 | | | OCCUPANTS. | | | | | | 3) ALL EXIT DOORS WILL REQUIRE PANIC HARDWARE 2010 | | | FBC-B 1008.1.10. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2014-03-26 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-03-26 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-03-26 |
Time |
10:56 |
Sent To |
I |
|
| Notes |
| 2014-03-26 11:37:03 | THIS APPLICATION WAS APPROVED CONTINGENT ON THE | | | ELECTRICAL CONDITIONS NOTED ON THE APPROVED PLANS. SOME | | | OF THOSE CONDITIONS ARE EXPRESSED ON THE PLANS BUT NOT | | | CLEARLY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2014-03-03 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-03-03 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-03-03 |
Time |
16:20 |
Sent To |
I |
|
| Notes |
| 2014-03-03 16:36:42 | OBVIOUSLY, ALL OF THE PRIOR ELECTRICAL PLAN REVIEW | | | COMMENTS HAVE BEEN IGNORED, IN CASE YOU DON'T HAVE | | | ACCESS TO A COPY OF THE FLORIDA BLDG. CODE, FOLLOWING | | | IS A RECAP OF ALL PREVIOUS COMMENTS ALONG WITH THE FBC | | | SECTION STATING THE MINIMUM REQUIREMENTS FOR PLAN | | | REVIEW. FBC-B 107.2.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED | | | AND DRAWN UPON SUITABLE MATERIAL. ELECTRONIC MEDIA | | | DOCUMENTS ARE PERMITTED TO BE SUBMITTED WHEN APPROVED | | | BY THE BUILDING OFFICIAL. CONSTRUCTION DOCUMENTS SHALL | | | BE OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, | | | NATURE AND EXTENT OF THE WORK PROPOSED AND SHOW IN | | | DETAIL THAT IT WILL CONFORM TO THE PROVISIONS OF THIS | | | CODE AND RELEVANT LAWS, ORDINANCES, RULES AND | | | REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL | | | AS INDICATED ON THE PREVIOUS REVIEW, NO ELECTRICAL | | | SHEET PROVIDED FOR ELECTRICAL REVIEW | | | AN ELECTRICAL SHEET REFLECTING THE OUTLET PLACEMENT | | | WITH THEIR DESIGNATED CIRCUIT FOR EACH ELECTRICAL | | | DEVICE INSTALLED, INC. EXIT & EMERGENCY LIGHTS. ALL | | | EMERGENCY LIGHTING SHALL BE CONNECTED TO A LIGHTING | | | CIRCUIT WITHIN THE AREA THEY OCCUPY. | | | THIS SHEET SHALL ALSO INCLUDE THE REQUIRED SIGN AND | | | SHOW WINDOW OUTLETS REQUIRED BY NEC. YOU SHALL ALSO | | | PROVIDE THE REQUIRED NUMBER OF SETS. | | | THOUGH MINIMAL, THERE ARE DIFFERENT ELECTRICAL | | | REQUIREMENTS FOR THE DIFFERENT OCCUPANCIES. AN | | | ELECTRICAL DRAWING SHOWING THE REQUIRED LIGHTING, EXIT | | | AND EMERGENCY LIGHTS AS WELL AS THE REQUIRED SIGN AND | | | SHOW WINDOW CIRCUITS. A PANEL SCHEDULE AND ELECTRICAL | | | LOAD CALCS SHALL BE PROVIDED. ALL LIGHTING AND SIGNAGE | | | SHALL ADHERE TO THE REQUIREMENTS OF THE FBC-ENERGY | | | CONSERVATION SECTION 505. | | | NO ELECTRICAL DRAWING PROVIDED.FOR REVIEW. | | | FOR ANY QUESTIONS OR COMMENTS ON THIS REVIEW, PLEASE | | | CONTACT: MIKE ALBARRAN, ELECTRICAL PLANS EXAMINER, | | | PX3353 | | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | | PH: (561) 805-6718, EMAIL: [email protected] | | | | | | | | 2014-02-28 09:49:43 | MALBARRAN TO REVIEW ELECTRICAL INFORMATION PROVIDED ON | | | SHEET LS-2 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-02-19 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-02-19 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-02-19 |
Time |
11:48 |
Sent To |
FIRE |
|
| Notes |
| 2014-02-19 12:12:34 | AS INDICATED ON THE PREVIOUS REVIEW, NO ELECTRICAL | | | SHEET PROVIDED FOR ELECTRICAL REVIEW | | | AN ELECTRICAL SHEET REFLECTING THE OUTLET PLACEMENT | | | WITH THEIR DESIGNATED CIRCUIT FOR EACH ELECTRICAL | | | DEVICE INSTALLED, INC. EXIT & EMERGENCY LIGHTS. | | | THIS SHEET SHALL ALSO INCLUDE THE REQUIRED SIGN AND | | | SHOW WINDOW OUTLETS REQUIRED BY NEC. YOU SHALL ALSO | | | PROVIDE THE REQUIRED NUMBER OF SETS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-01-08 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-01-08 |
Time |
18:18 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-01-08 |
Time |
18:12 |
Sent To |
FIRE |
|
| Notes |
| 2014-01-08 18:23:39 | THOUGH MINIMAL, THERE ARE DIFFERENT ELECTRICAL | | | REQUIREMENTS FOR THE DIFFERENT OCCUPANCIES. AN | | | ELECTRICAL DRAWING SHOWING THE REQUIRED LIGHTING, EXIT | | | AND EMERGENCY LIGHTS AS WELL AS THE REQUIRED SIGN AND | | | SHOW WINDOW CIRCUITS. A PANEL SCHEDULE AND ELECTRICAL | | | LOAD CALCS SHALL BE PROVIDED. ALL LIGHTING AND SIGNAGE | | | SHALL ADHERE TO THE REQUIREMENTS OF THE FBC-ENERGY | | | CONSERVATION SECTION 505. | | | NO ELECTRICAL DRAWING PROVIDED.FOR REVIEW. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2014-02-24 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2014-02-24 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2014-02-24 |
Time |
11:36 |
Sent To |
I |
|
| Notes |
| 2014-02-19 12:14:17 | ROUTED TO FIRE BIN |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2014-01-13 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2014-01-13 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2014-01-13 |
Time |
16:52 |
Sent To |
I |
|
| Notes |
| 2014-01-13 17:18:10 | PERMIT #13120518 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | ***FAILED COMMENTS**** | | | | | | WHERE SOCCER FIELD #4 IS TO BE LOCATED, THERE SHOWS A | | | FAX/COPY ROOM. THIS ROOM SHOULD BE RELOCATED TO AN AREA | | | NOT OCCUPIED BY A FIELD. | | | | | | ALL EXIT DOORS SHALL BE EQUIPPED WITH PANIC HARDWARE. | | | | | | PRODUCT DETAILS FOR EQUIPMENT AND/OR FURNISHINGS TO BE | | | USED INSIDE SOCCER FIELD #4 AND ON THE FIRST FLOOR | | | EXERCISE ROOM NEED TO BE PROVIDED. THE INTERIOR FINISH | | | MATERIALS FOR WALLS, CEILINGS, AND FLOORS SHALL MEET | | | THE REQUIRED SMOKE DEVELOPMENT AND FLAME SPREAD | | | REQUIREMENTS. | | | | | | EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED SEATS | | | SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED IN A | | | CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE ROOM. | | | SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF | | | OCCUPANTS PERMITTED FOR EACH ROOM. | | | | | | SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | | | | PROVIDE DRAWING NOTE INDICATING ALL CONSTRUCTION AND | | | DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS OF | | | NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE | | | REMOVED FROM THE SITE DAILY. SMOKING SHALL BE | | | PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL | | | OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO | | | SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE | | | RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED. | | | | | | PROVIDE DRAWING NOTE INDICATING, ?FIRE PROTECTION | | | SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND | | | RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION | | | SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A | | | 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A | | | FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED | | | BY EMAIL ([email protected]) OR IN WRITING (FAX: | | | 561-804-4774) AND APPROVED BY THE OFFICE OF THE FIRE | | | MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.? | | | | | | | | | SUE ELLEN CALDERON | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4751 | | | | | 2014-01-08 18:27:20 | PLACED IN FIRE BIN |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2014-03-26 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-03-26 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-03-26 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2014-03-26 11:41:04 | TO SAK FOR DETERMINATION OF ROUTING TO IMPACT | | | | | 2014-03-26 09:45:39 | TO MA DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2014-03-14 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-03-14 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-03-14 |
Time |
13:17 |
Sent To |
E |
|
| Notes |
| 2014-03-14 13:17:57 | SENT TO MALBARRAN DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
F |
Date |
2014-03-03 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-03-03 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-02-28 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2014-03-03 16:46:12 | SMALL DENIED BIN "D" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-02-24 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2014-02-24 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2014-02-14 |
Time |
12:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-01-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-01-13 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-12-12 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2013-12-12 14:32:57 | EXPEDITED C07 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
N |
Date |
2014-03-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-03-28 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-03-28 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2014-03-28 14:16:31 | 3/38/2014 | | | P B COUNTY IMPACT FEE ASSESSMENT | | | MU201210236 | | | NO FEES DUE |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2014-03-26 |
|
|
Cont ID |
|
| Sent By |
JWITMER |
Date |
2014-03-26 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2014-03-26 14:13:46 | SEE PREVIOUS REVIEW COMMENTS. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2013-12-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-12-27 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-12-27 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2013-12-27 15:58:00 | ONLY THE NEW 1ST FLOOR GYM WILL NEED TO BE ASSESSED, | | | THE NEW 2ND FLOOR SOCCER FIELD WAS ASSESSED UNDER | | | PERMIT 12030117/ COUNTY IMPACT # MU 2012 010236 0000. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2014-01-02 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-01-02 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-01-02 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2014-01-02 14:37:50 | NO MECHANICAL PLAN SUBMITTED. | | | HAVE AIRCONDITIONING CONTRACTOR SUBMIT | | | HIS OWN APPLICATION AND PLANS FOR PERMIT. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6676 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2013-12-30 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-12-30 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-12-30 |
Time |
07:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-12-20 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2013-12-20 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2013-12-18 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2013-12-18 10:35:40 | 12/18/13 |
|
|