Plan Review Details - Permit 13120278
Plan Review Stops For Permit 13120278
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-03-25 Cont ID  
Sent By jwitmer Date 2014-03-25 Time 10:49 Rev Time 0.00
Received By jwitmer Date 2014-03-25 Time 10:49 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-01-06 Cont ID  
Sent By jwitmer Date 2014-01-06 Time 13:12 Rev Time 0.00
Received By jwitmer Date 2014-01-06 Time 11:21 Sent To  
Notes
2014-01-06 13:12:12BUILDING PLAN REVIEW
 PERMIT: 13120278
 ADD: 828 SOUTHERN BLVD
 CONT: MCINTYRE & ELWELL & STRAMMER GC INC
 TEL: (941)377-6800
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. JAN. 06/2014
 ACTION: DENIED
  
 1) PLEASE PROVIDE A LIFE SAFETY PLAN, SHEET A1 & A2
 FLOOR PLAN & THE REFLECTED CEILING PLAN INDICATE TWO
 MEANS OF EGRESS THAT TAKE THE GENERAL PUBLIC THROUGH
 THE STOCKROOM AREAS. SHEET A7 SHOWS THESE TWO AREAS
 WITH THE FLOORS PAINTED WITH A DEMARCATED EGRESS PATH,
 BUT 2010 FBC-B 1014.2.4 DOES ALLOW EGRESS THROU STORAGE
 ROOMS WHEN ALL THE FOLLOWING ARE MET: 2. MEANS OF
 EGRESS ARE NOT PROHIBITED THROUGH STOCKROOMS IN GROUP M
 OCCUPANCIES WHEN ALL OF THE FOLLOWING ARE MET:
  
 2.1. THE STOCK IS OF THE SAME HAZARD CLASSIFICATION AS
 THAT FOUND IN THE MAIN RETAIL AREA;
  
 2.2. NOT MORE THAN 50 PERCENT OF THE EXIT ACCESS IS
 THROUGH THE STOCKROOM;
  
 2.3. THE STOCKROOM IS NOT SUBJECT TO LOCKING FROM THE
 EGRESS SIDE; AND
  
 2.4. THERE IS A DEMARCATED, MINIMUM 44-INCH-WIDE (1118
 MM) AISLE DEFINED BY FULL- OR PARTIAL-HEIGHT FIXED
 WALLS OR SIMILAR CONSTRUCTION THAT WILL MAINTAIN THE
 REQUIRED WIDTH AND LEAD DIRECTLY FROM THE RETAIL AREA
 TO THE EXIT WITHOUT OBSTRUCTIONS.
  
 2) SHEET A-9A DETAIL DETAIL D3 INDICATES 3 5/8 INCH
 FULL LENGTH STUDS AT 16 INCHES ON CENTER BUT THE
 MAXIMUM LENGTH OF STUD IS NOT PROVIDED NOR GAUGE OF
 STUD OR DEFLECTION,
 2010 FBC-B TABLE 1604.3 & TABLE 2506.2 STEEL STUDS, NON
 LOAD BEARING.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2014-03-05 Cont ID  
Sent By malbarra Date 2014-03-05 Time 17:43 Rev Time 0.00
Received By albarran Date 2014-03-05 Time 17:05 Sent To  
Notes
2014-03-05 17:44:02RE-STAMP NEW PLAN SHEETS. RETURNED TO BIN FOR FURTHER
 REVIEWS.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-01-27 Cont ID  
Sent By albarran Date 2014-01-27 Time 18:49 Rev Time 0.00
Received By albarran Date 2014-01-27 Time 17:04 Sent To P
Notes
2014-01-27 18:50:23AS NOTED ON APPROVED DRAWINGS:
 ALL CONDUCTORS SHALL BE LISTED FOR APPLICATION.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2014-03-17 Cont ID  
Sent By lphilmor Date 2014-03-17 Time 13:54 Rev Time 0.00
Received By scaldero Date 2014-03-17 Time 13:54 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-01-08 Cont ID  
Sent By lphilmor Date 2014-01-08 Time 14:27 Rev Time 0.00
Received By lphilmor Date 2014-01-08 Time 14:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-03-25 Cont ID  
Sent By jwitmer Date 2014-03-25 Time 10:50 Rev Time 0.00
Received By jwitmer Date 2014-02-27 Time 15:41 Sent To  
Notes
2014-02-27 15:41:47C25

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-01-28 Cont ID  
Sent By jwitmer Date 2014-01-28 Time 10:35 Rev Time 0.00
Received By jwitmer Date 2013-12-06 Time 08:16 Sent To  
Notes
2013-12-07 08:18:47C35

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2014-01-03 Cont ID  
Sent By shill Date 2013-12-19 Time 11:37 Rev Time 0.00
Received By hmoser Date 2014-01-03 Time 11:37 Sent To  
Notes
2014-01-03 11:37:57PLAN REVIEW BY J SAIS PX 1328
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2014-03-25 Cont ID  
Sent By jwitmer Date 2014-03-25 Time 10:49 Rev Time 0.00
Received By jwitmer Date 2014-03-25 Time 10:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2014-01-28 Cont ID  
Sent By jwitmer Date 2014-01-28 Time 10:35 Rev Time 0.00
Received By jwitmer Date 2014-01-28 Time 10:35 Sent To  
Notes
2014-01-27 18:50:58RETURNED TO BIN C35
  

Review Stop Z ZONING
Rev No 1 Status P Date 2013-12-10 Cont ID  
Sent By ajones Date 2013-12-10 Time 11:17 Rev Time 0.00
Received By ajones Date 2013-12-10 Time 11:17 Sent To  
Notes
2013-12-10 11:17:46VALUE DOES NOT EXCEED 50%