Plan Review Details - Permit 13120266
Plan Review Stops For Permit 13120266
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-01-29 Cont ID  
Sent By jwitmer Date 2014-01-29 Time 10:30 Rev Time 0.00
Received By jwitmer Date 2014-01-29 Time 10:17 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2013-12-27 Cont ID  
Sent By jwitmer Date 2013-12-27 Time 16:45 Rev Time 0.00
Received By jwitmer Date 2013-12-27 Time 16:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2014-02-03 Cont ID  
Sent By albarran Date 2014-02-03 Time 11:45 Rev Time 0.00
Received By albarran Date 2014-02-03 Time 11:45 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2014-01-29 Cont ID  
Sent By albarran Date 2014-01-29 Time 10:07 Rev Time 0.00
Received By albarran Date 2014-01-29 Time 09:52 Sent To  
Notes
2014-01-29 10:12:41THIS RESUBMITAL APPEARS TO HAVE BEEN MADE WITH TOTAL
 DISREGARD TO MY NOTES AS NONE OF THE PREVIOUSLY MADE
 COMMENTS HAVE BEEN ADDRESSED.
 PLEASE SUBMITT CORRECTED SHEETS IN ADDITION TO THE
 EXISTING FOR COMPARISON. IN LIEU OF CONDUCTOR
 INSULATION AS REQUESTED, A NOTE OF COMPLIANCE WITH THE
 REQUIREMENTS OF NEC 300.5(B) SHALL BE SUFFICIENT.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-01-09 Cont ID  
Sent By albarran Date 2014-01-09 Time 18:21 Rev Time 0.00
Received By albarran Date 2014-01-08 Time 19:16 Sent To  
Notes
2014-01-09 18:36:06THIS APPLICATION FAILED THE FIRST REVIEW AS OUTLINED
 BELOW:
 1. PG. 1.1 LIGHTING: AS PER NEC 600.5 EVERY COMMERCIAL
 BLDG. SHALL HAVE AT LEAST ONE OUTLET FOR SIGNAGE AT
 EACH ENTRANCE
 2. PG. 2.1 POWER PLAN, I WAS UNABLE TO FIND A WATER
 COOLER WHICH IS USUALLY IN THIS TYPE OF ESTABLISHMENT,
 NOR COULD I VERIFY IT WITH THE PANEL SCHEDULES. I WAS
 VERIFYING THAT IT HAD BEEN SERVED WITH A GFI PROTECTED
 CIRCUIT.
 3. PG. 2.2 ROOF POWER PLAN: NEC 210.63 REQUIRES THAT
 THERE BE A SERVICE OUTLET WITHIN 25' OF THE CONDENSING
 UNITS. NEC 210.8 REQUIRES THAT THE OUTLET BE GFI
 PROTECTED. NEC 406.8 REQUIRES THAT THE OUTLET BE "WR"
 WEATHER RESISTANT RATED AND THAT IT HAVE AN IN-USE TYPE
 COVER.
 4. PG. 3.1 RISER & DETAILS: YOU FAIL TO PROVIDE THE
 CONDUCTOR INSULATION AND RACEWAY TYPES.
 5. PG. 4.1 ELECTRICAL PANEL SCHEDULES: THIS PAGE HAS A
 MALFUNCTION WHICH DOES NOT LET ME PROPERLY OPEN THE
 PAGE OR MANEUVER WITHIN THE MINIMIZED VIEW TO PROPERLY
 REVIEW IT.
 6. PG. 5.1 FIRE ALARM: AS NOTED, THIS IS NOT SUFFICIENT
 DOCUMENTATION OR DESIGN FOR A FIRE ALARM SUBMISSION. AS
 SEPARATE FIRE ALARM PERMIT AND SUBMITTAL PACKAGE SHALL
 BE SECURED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2014-01-17 Cont ID  
Sent By wjolin Date 2014-01-17 Time 08:19 Rev Time 0.00
Received By wjolin Date 2014-01-17 Time 08:18 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-01-07 Cont ID  
Sent By wjolin Date 2014-01-07 Time 14:33 Rev Time 0.00
Received By wjolin Date 2014-01-07 Time 13:23 Sent To E
Notes
2014-01-07 14:06:141250 NORTHPOINT PKWY
 PERMIT # 13120266
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 SHEET A0.02 -PER SECTION 7.2.1.6.2, ACCESS-CONTROLLED
 EGRESS DOORS ARE PERMITTED PROVIDED THAT ALL SEVEN OF
 THE FOLLOWING CRITERIA ARE MET:
 1. A SENSOR SHALL BE PROVIDED ON THE EGRESS SIDE,
 ARRANGED TO DETECT AN OCCUPANT APPROACHING DOORS THAT
 ARE ARRANGED TO UNLOCK IN THE DIRECTION OF EGRESS UPON
 DETECTION OF AN APPROACHING OCCUPANT OR LOSS OF POWER
 TO THE SENSOR.
 2. LOSS OF POWER TO THE PART OF THE ACCESS CONTROL
 SYSTEM THAT LOCKS THE DOORS SHALL AUTOMATICALLY UNLOCK
 THE DOORS IN THE DIRECTION OF EGRESS.
 3. THE DOORS SHALL BE ARRANGED TO UNLOCK IN THE
 DIRECTION OF EGRESS FROM A MANUAL RELEASE DEVICE
 LOCATED VERTICALLY 40 TO 48 INCHES ABOVE THE FLOOR AND
 WITHIN 60 INCHES HORIZONTALLY OF THE SECURED DOORS.
 4. THE MANUAL RELEASE DEVICE SHALL BE READILY
 ACCESSIBLE AND CLEARLY IDENTIFIED BY A SIGN THAT READS
 PUSH TO EXIT.
 5. WHEN OPERATED, THE MANUAL RELEASE DEVICE SHALL
 RESULT IN DIRECT INTERRUPTION OF POWER TO THE LOCK,
 INDEPENDENT OF THE ACCESS CONTROL SYSTEM ELECTRONICS,
 AND THE DOORS SHALL REMAIN UNLOCKED FOR NOT LESS THAN
 30 SECONDS.
 6. ACTIVATION OF THE BUILDING FIRE ALARM SYSTEM SHALL
 AUTOMATICALLY UNLOCK THE DOORS IN THE DIRECTION OF
 EGRESS, AND THE DOORS SHALL REMAIN UNLOCKED UNTIL THE
 FIRE ALARM SYSTEM HAS BEEN MANUALLY RESET.
 7. ACTIVATION OF THE BUILDING AUTOMATIC SPRINKLER
 SYSTEM OR AUTOMATIC DETECTION SYSTEM SHALL
 AUTOMATICALLY UNLOCK THE DOORS IN THE DIRECTION OF
 EGRESS, AND THE DOORS SHALL REMAIN UNLOCKED UNTIL THE
 FIRE ALARM SYSTEM HAS BEEN MANUALLY RESET.
  
 SHEET E5.1 - PROVIDE SMOKE DETECTION ABOVE DOORS WITH
 MAGNETIC HOLD OPEN DEVICES.
  
  
 LAUREN PHILMORE
 FIRE INSPECTOR II/INVESTIGATOR 1
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4783
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-02-13 Cont ID  
Sent By rregueir Date 2014-02-13 Time 15:53 Rev Time 0.00
Received By rregueir Date 2014-02-03 Time 09:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2014-01-31 Time   Rev Time 0.00
Received By rregueir Date 2014-01-16 Time 16:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-01-10 Cont ID  
Sent By rregueir Date 2014-01-10 Time 08:16 Rev Time 0.00
Received By rregueir Date 2013-12-06 Time 13:17 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2013-12-16 Cont ID  
Sent By rregueir Date 2013-12-16 Time 13:19 Rev Time 0.00
Received By rregueir Date 2013-12-16 Time 13:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-12-19 Cont ID  
Sent By lwagner Date 2013-12-19 Time 14:48 Rev Time 0.00
Received By lwagner Date 2013-12-19 Time 14:19 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2014-01-23 Cont ID  
Sent By rregueir Date 2014-01-23 Time 16:41 Rev Time 0.00
Received By rregueir Date 2014-01-23 Time 16:41 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2014-02-13 Cont ID  
Sent By llouie Date 2014-02-13 Time 14:11 Rev Time 0.50
Received By eschneid Date 2014-02-13 Time 14:11 Sent To  
Notes
2014-02-13 14:12:12ZONING PROVISO - PRIOR TO THE FINAL (104) ISSUANCE, A
 LANDSCAPE PERMIT, INC. A REVISED LANDSCAPE PLAN SHOWING
 COMPLIANCE WITH THE CITY'S LANDSCAPE REQUREMENTS, SHALL
 BE SUBMITTED AND THE LANDSCAPE SHALL BE INSTALLED AND
 PASS INSPECTION.
2014-02-10 16:15:472/10/14

Review Stop Z ZONING
Rev No 2 Status F Date 2014-01-31 Cont ID  
Sent By eschneid Date 2014-01-31 Time 13:43 Rev Time 0.50
Received By eschneid Date 2014-01-31 Time 13:43 Sent To  
Notes
2014-01-31 13:53:14FAILED
  
 1) REPEAT COMMENT: THE VALUE OF THE CONSTRUCTION
 ($875,000) EXCEEDS 50% OF THE STRUCTURE'S VALUE
 ($903,251) ACCORDING TO THE P.B.C. PROPERTY APPRAISER'S
 OFFICE; THEREFORE, PURSUANT TO SECTION 94-441(C)(2) OF
 THE ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR), THE
 LANDSCAPE ON THE SITE SHALL BE IN COMPLIANCE WITH ALL
 APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF THE
 ZLDR. IF THE SITE CONFORMS TO ARTICLE XIV, THEN TWO (2)
 COPIES OF A LANDSCAPE PLAN DEMONSTRATING COMPLIANCE
 SHALL BE INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE
 SITE DOES NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE
 ZONING APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE
 PERMIT AND IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING
 MATERIAL TO BRING THE SITE INTO CONFORMITY.
  
 JANUARY 31, 2014 - SPOKE WITH KEN REGARDING THE VALUE
 OF THE SITE. THE RECENT PURCHASE IS NOT SUFFICIENT
 EVIDENCE THAT THE CONSTRUCTION IS LESS THAN 50% OF THE
 VALUE OF THE BUILDING. ALSO DISCUSSED WAS THAT IF THE
 EXISTING LANDSCAPE WAS BROUGHT INTO CONFORMANCE (IF IT
 IS NOT ALREADY SO) TO THE APPROVED LANDSCAPE PLAN FROM
 WHEN THE BUILDING WAS CONSTRUCTED, THEN THE COMMENT IS
 SATISFIED. BOTH KEN AND THE CITY ARE LOOKING FOR A COPY
 OF THE ORIGINAL LANDSCAPE PLAN.
  
 2) THE BUILDING ITSELF MEETS ZONING.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
2014-01-27 14:19:271/27/14

Review Stop Z ZONING
Rev No 1 Status F Date 2013-12-18 Cont ID  
Sent By ajones Date 2013-12-18 Time 10:51 Rev Time 0.50
Received By eschneid Date 2013-12-18 Time 10:51 Sent To  
Notes
2013-12-18 22:35:27FAILED
  
 1) THE VALUE OF THE CONSTRUCTION ($875,000) EXCEEDS 50%
 OF THE STRUCTURE'S VALUE ($903,251) ACCORDING TO THE
 P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT
 TO SECTION 94-441(C)(2) OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE
 SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE
 REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE
 SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A
 LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE
 INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES
 NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING
 APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND
 IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL
 TO BRING THE SITE INTO CONFORMITY.
  
 2) THE BUILDING ITSELF MEETS ZONING.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved