Plan Review Details - Permit 13120246
Plan Review Stops For Permit 13120246
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2014-03-07 Cont ID  
Sent By skennedy Date 2014-03-07 Time 16:36 Rev Time 0.00
Received By skennedy Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2014-02-24 Cont ID  
Sent By shill Date 2014-02-24 Time 14:24 Rev Time 0.00
Received By shill Date 2014-02-24 Time 14:24 Sent To  
Notes
2014-02-24 14:26:22****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. COMMENT FROM PREVIOUS REVIEWS:
  
 4TH REVIEW -
  
 PER CONTRACTOR, DIRECT DECK PROPOSED.
  
 CONTRACTOR STILL NEEDS TO SELECT AN ASSEMBLY. FIRST
 SUBMITTAL INDICATED AN ASSEMBLY WHICH HAD A DP
 LIMITATION OF -90.
  
 2ND SUBMITTAL HAD ENHANCED FASTENING FOR EXPOSURE C FOR
 MECHANICALLY FASTENED.
  
 3RD SUBMITTAL HAD A LETTER AND OTHER INFO REGARDING
 DIRECT DECK, BUT CONTRACTOR HAS NOT YET SELECTED A
 DIRECT DECK ASSEMBLY WHICH WILL MEET ***EXPOSURE D**
 PRESSURES. ADDITIONALLY, THE ENGINEER'S CALCULATIONS
 ARE BASED ON EXPOSURE C, BUT THIS PARCEL IS LOCATED IN
 EXPOSURE D CONDITIONS, SEE FBC 2010 RESIDENTIAL 301.
  
 4TH SUBMITTAL HAD A DETAIL (DRAWING). ON THE PRODUCT
 APPROVAL, INDICATE WHICH APPROVED ASSEMBLY IS PROPOSED
 TO SHOW COMPLIANCE WITH FBC 2010 RESIDENTIAL 301.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2014-01-11 Cont ID  
Sent By shill Date 2014-01-11 Time 11:10 Rev Time 0.00
Received By shill Date 2014-01-11 Time 11:10 Sent To  
Notes
2014-01-11 11:13:56****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. COMMENT FROM PREVIOUS REVIEWS:
  
 PROPOSED ASSEMBLY HIGHLIGHTED BY CONTRACTOR HAS AN
 ALLOWABLE DP OF -90. EXISTING DECK IS WOOD PLAN, DECK
 REQUIRED BY ASSEMBLY SELECTED IS PLYWOOD.
  
 3RD REVIEW -
  
 PER CONTRACTOR, DIRECT DECK PROPOSED, SO THE ENGINEER'S
 CALCULATIONS FOR ENHANCED FASTENING IS NOT REQUIRED.
  
 CONTRACTOR STILL NEEDS TO SELECT AN ASSEMBLY. FIRST
 SUBMITTAL INDICATED AN ASSEMBLY WHICH HAD A DP
 LIMITATION OF -90.
  
 2ND SUBMITTAL HAD ENHANCED FASTENING FOR EXPOSURE C FOR
 MECHANICALLY FASTENED.
  
 3RD SUBMITTAL HAD A LETTER AND OTHER INFO REGARDING
 DIRECT DECK, BUT CONTRACTOR HAS NOT YET SELECTED A
 DIRECT DECK ASSEMBLY WHICH WILL MEET ***EXPOSURE D**
 PRESSURES. ADDITIONALLY, THE ENGINEER'S CALCULATIONS
 ARE BASED ON EXPOSURE C, BUT THIS PARCEL IS LOCATED IN
 EXPOSURE D CONDITIONS, SEE FBC 2010 RESIDENTIAL 301.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2013-12-21 Cont ID  
Sent By shill Date 2013-12-21 Time 14:10 Rev Time 0.00
Received By shill Date 2013-12-21 Time 14:10 Sent To  
Notes
2013-12-21 14:14:31****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. ENGINEERING IS NOT CONSISTENT WITH PROPOSED
 CONSTRUCTION. ENGINEERING IS FOR SELF ADHERED ASSEMBLY,
 NO ASSEMBLY NUMBER PROVIDED BUT ALLOWABLE DESIGN
 PRESSURE IS -112 (ON ENGINEERING).
  
 PROPOSED ASSEMBLY HIGHLIGHTED BY CONTRACTOR HAS AN
 ALLOWABLE DP OF -90. EXISTING DECK IS WOOD PLAN, DECK
 REQUIRED BY ASSEMBLY SELECTED IS PLYWOOD.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-12-05 Cont ID  
Sent By shill Date 2013-12-05 Time 17:12 Rev Time 0.00
Received By shill Date 2013-12-05 Time 17:12 Sent To  
Notes
2013-12-05 17:16:46****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. ROOF FORM IS ILLEGIBLE. PLEASE SUBMIT LEGIBLE
 COPIES.
  
 2. SPECIFY TYPE OF WOOD DECK - PLYWOOD OR PLANK.
  
 3. PROPOSED DESIGN PRESSURES ARE NOT CLEAR BUT APPEAR
 TO BE 76.019 IN THE CORNER, PROVIDE CALCULATIONS.
 EXPOSURE WAS LEFT BLANK; THIS IS EXPOSURE D. IT IS NOT
 CLEAR HOW PRESSURES LOWER THAN EXPOSURE C HAVE BEEN
 DETERMINED. ZONE 3, EXPOSURE D, HAS A DP OF -127.3
 USING TABLES FBC RESIDENTIAL 2010 301.2(2), (3).
  
 4. DRAIN INSTALLATION REQUIRES A PLUMBING PERMIT.
 PROVIDE PLAN AND PERMIT APPLICATION.
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-02-24 Cont ID  
Sent By shill Date 2014-02-24 Time 14:26 Rev Time 0.00
Received By shill Date 2014-02-20 Time 14:33 Sent To  
Notes
2014-02-21 14:34:22TO SH DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-12-21 Cont ID  
Sent By shill Date 2013-12-21 Time 14:14 Rev Time 0.00
Received By shill Date 2013-12-14 Time 07:28 Sent To  
Notes
2013-12-14 07:28:47SENT TO S HILL


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved