Plan Review Details - Permit 13120107
| Plan Review Stops For Permit 13120107 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-12-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-12-22 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-12-22 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-12-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-12-05 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-12-05 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2013-12-05 09:43:49 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. REVISE FLOOR PLAN TO INCLUDE ROOM DESIGNATIONS, FBC | | | R310, FBC EB 604.1. THE CLEAR OPENING CANNOT BE REDUCED | | | BY MORE THAN 5%. | | | | | | 2. IF THE PROPOSED NEW BEDROOM WINDOWS DO NOT COMPLY | | | WITH EMERGENCY ESCAPE AND RESCUE OPENING DIMENSIONS, | | | AND ANOTHER EXISTING EMERGENCY ESCAPE AND RESCUE | | | OPENING IS NOT PROVIDED, ALSO PROVIDE THE FOLLOWING | | | INFORMATION (FOR BEDROOMS ONLY); FBC R310, FBC EB | | | 604.1. THE CLEAR OPENING CANNOT BE REDUCED BY MORE THAN | | | 5%: | | | | | | REVISE PLAN TO STATE WHAT TYPE OF WINDOW IS THERE NOW | | | IN THE BEDROOMS - AWNING, CASEMENT, SINGLE HUNG? | | | | | | REVISE PLAN TO STATE WHAT THE EXISTING CLEAR OPENING | | | DIMENSIONS ARE. CLEAR OPENING IS THE OPENING WHICH | | | EXISTS WHEN THE WINDOW IS FULLY OPEN. | | | | | | REVISE PLAN TO STATE WHAT THE PROPOSED CLEAR OPENING | | | DIMENSIONS ARE. THIS CAN BE OBTAINED FROM THE | | | MANUFACTURER | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-12-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-12-22 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-12-09 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2013-12-09 13:30:24 | TO SH DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-12-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-12-05 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-12-03 |
Time |
17:17 |
Sent To |
|
|
| Notes |
| 2013-12-03 17:19:50 | INCOMING SENT TO MISC BOX # 1. JW |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |