| 2013-12-19 13:33:48 | BUILDING PLAN REVIEW |
| | REVISION : 13120085 |
| | PERMIT: 13070818 |
| | ADD: 1807 PALM BEACH LAKES |
| | CONT: HALEY CONSTRUCTION |
| | TEL: (954)202-7000 JESSICA |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: THURSDAY, DEC. 19/2013 |
| | ACTION: BUILDING APPROVED WITH EXCEPTION! |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| | |
| | 1) ADDITIONAL INFORMATION IS REQUIRED TO DETERMINE CODE |
| | COMPLIANCE ON THE OVERHEAD GARAGE DOORS LOCATED ON |
| | SHEET A1.3 & A4.02 DETAIL # 5. I'VE SPOKEN WITH PROJECT |
| | ARCHITECT JAMIE KNOLLMILLER AND TTHE OVERHEAD DOORS |
| | WILL BE IN THE HORIZONTAL POSITION. SINCE THERE IS |
| | GLAZING IN THESE OVERHEAD DOORS PLEASE SUBMIT PRODUCT |
| | INFORMATION PROVIDING CODE COMPLIANCE WITH SECTION: |
| | 2405.1 SCOPE. |
| | THIS SECTION APPLIES TO THE INSTALLATION OF GLASS AND |
| | OTHER TRANSPARENT, TRANSLUCENT OR OPAQUE GLAZING |
| | MATERIAL INSTALLED AT A SLOPE MORE THAN 15 DEGREES |
| | (0.26 RAD) FROM THE VERTICAL PLANE, INCLUDING GLAZING |
| | MATERIALS IN SKYLIGHTS, ROOFS AND SLOPED WALLS. |
| | |
| | 2405.2 ALLOWABLE GLAZING MATERIALS AND LIMITATIONS. |
| | SLOPED GLAZING SHALL BE ANY OF THE FOLLOWING MATERIALS, |
| | SUBJECT TO THE LISTED LIMITATIONS. |
| | |
| | 1. FOR MONOLITHIC GLAZING SYSTEMS, THE GLAZING MATERIAL |
| | OF THE SINGLE LIGHT OR LAYER SHALL BE LAMINATED GLASS |
| | WITH A MINIMUM 30-MIL (0.76 MM) POLYVINYL BUTYRAL (OR |
| | EQUIVALENT) INTERLAYER, WIRED GLASS, LIGHT-TRANSMITTING |
| | PLASTIC MATERIALS MEETING THE REQUIREMENTS OF SECTION |
| | 2607, HEAT-STRENGTHENED GLASS OR FULLY TEMPERED GLASS. |
| | |
| | 2. FOR MULTIPLE-LAYER GLAZING SYSTEMS, EACH LIGHT OR |
| | LAYER SHALL CONSIST OF ANY OF THE GLAZING MATERIALS |
| | SPECIFIED IN ITEM 1 ABOVE. |
| | |
| | ANNEALED GLASS IS PERMITTED TO BE USED AS SPECIFIED |
| | WITHIN EXCEPTIONS 2 AND 3 OF SECTION 2405.3. |
| | |
| | FOR ADDITIONAL REQUIREMENTS FOR PLASTIC SKYLIGHTS, SEE |
| | SECTION 2610. GLASS-BLOCK CONSTRUCTION SHALL CONFORM TO |
| | THE REQUIREMENTS OF SECTION 2101.2.5. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |