Plan Review Details - Permit 13120015
Plan Review Stops For Permit 13120015
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2014-05-23 Cont ID  
Sent By rmcdouga Date 2014-05-23 Time 16:49 Rev Time 0.00
Received By rmcdouga Date 2014-05-23 Time 16:49 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2014-05-09 Cont ID  
Sent By rmcdouga Date 2014-05-09 Time 18:52 Rev Time 0.00
Received By rmcdouga Date 2014-05-09 Time 13:45 Sent To  
Notes
2014-05-09 18:54:332010 FBC
  
 DENIED BY BUILDING
  
 1) THE VALUE SPECIFIED ON THE APPLICATION APPEARS TO BE
 LOW FOR THE SCOPE OF WORK SPECIFIED. PLEASE INCLUDE THE
 COSTS OF ALL MATERIAL, LABOR AND DESIGN COSTS FOR ALL
 TRADES, AS WELL AS, PROFIT AND OVERHEAD. CITY
 AMENDMENTS 109.3
  
 2) THE PLANS INDICATE THAT AN EXISTING ENCLOSED FRONT
 PORCH AREA OF 96 SQFT IS BEING CONVERTED TO LIVING
 AREA. THIS WILL REQUIRE ONE SET OF THE APPROVED PLANS
 TO BE REVIEWED BY PALM BEACH COUNTY TO DETERMINE IF ANY
 IMPACT FEES ARE DUE.
  
 3) SEPARATE PERMITS ARE REQUIRED FOR THE DRIVEWAYS AND
 APPROACH APRONS.
  
 NOTE: PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW
 EACH OF THE PLAN REVIEW COMMENTS HAS BEEN ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-01-13 Cont ID  
Sent By rmcdouga Date 2014-01-13 Time 16:53 Rev Time 0.00
Received By rmcdouga Date 2014-01-13 Time 13:46 Sent To  
Notes
2014-01-13 14:01:352010 FBC
  
 DENIED BY BUILDING
  
 1) THE PLANS INDICATE THAT THIS IS AN EXISTING TWO -
 FAMILY DWELLING. THE EXISTING FLOOR PLAN IS UNCLEAR
 ABOUT THE LOCATION OF THE SEPARATION WALL BETWEEN THE
 TWO UNITS. THE PROPOSED FLOOR PLAN SHOWS THAT NEW WALLS
 ARE BEING INSTALLED THAT WILL RECONFIGURE THE TWO
 SPACES AND CHANGE THE LOCATION OF THE DEMISING WALL.
 FBC R302.3 REQUIRES THE TWO DWELLING UNITS TO BE
 SEPARATED FROM EACH OTHER BY A ONE HOUR FIRE-RESISTANCE
 RATED WALL ASSEMBLY. THE FIRE RATED WALL ASSEMBLY IS
 REQUIRED TO EXTEND TO AND BE TIGHT AGAINST THE EXTERIOR
 WALL AND EXTEND FROM THE FOUNDATION AND BE TIGHT
 AGAINST THE UNDER SIDE OF THE ROOF SHEATHING. DESIGNATE
 THIS WALL ON THE FLOOR PLAN AND PROVIDE A WALL ASSEMBLY
 DETAIL WITH THE UL LISTING NUMBER FOR IT.
  
 2) IT APPEARS THAT A NEW BEDROOM WITH A CLOSET HAS BEEN
 CREATED IN THE UNIT ON THE LEFT. FBC R310 REQUIRES
 EVERY SLEEPING ROOM TO HAVE AT LEAST ONE EMERGENCY
 ESCAPE AND RESCUE OPENING. PLEASE SHOW COMPLIANCE.
  
 3) SHOW COMPLIANCE WITH FBC R314 FOR SMOKE ALARMS IN
 SLEEPING ROOMS.
  
 4) PROVIDE AN EXTERIOR WALL SECTION FOR THE " IN-FILL"
 AT THE SLIDING GLASS DOOR THAT SPECIFIES THE INTERIOR
 FINISH, THE INSULATION, THE WATER RESISTIVE BARRIER AND
 THE EXTERIOR WALL FINISH. CITY AMENDMENTS 107.2.1
  
 5) THE VALUE SPECIFIED ON THE APPLICATION APPEARS TO BE
 LOW FOR THE SCOPE OF WORK SPECIFIED. PLEASE INCLUDE THE
 COSTS OF ALL MATERIAL, LABOR AND DESIGN COSTS FOR ALL
 TRADES, AS WELL AS, PROFIT AND OVERHEAD. CITY
 AMENDMENTS 109.3
  
 6) THE PLANS INDICATE THAT AN EXISTING ENCLOSED FRONT
 PORCH AREA OF 96 SQFT IS BEING CONVERTED TO LIVING
 AREA. THIS WILL REQUIRE ONE SET OF THE APPROVED PLANS
 TO BE REVIEWED BY PALM BEACH COUNTY TO DETERMINE IF ANY
 IMPACT FEES ARE DUE.
  
 7) SEPARATE PERMITS ARE REQUIRED FOR THE DRIVEWAYS AND
 APPROACH APRONS.
  
 NOTE: PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW
 EACH OF THE PLAN REVIEW COMMENTS HAS BEEN ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-05-09 Cont ID  
Sent By rmcdouga Date 2014-05-09 Time 18:18 Rev Time 0.00
Received By rmcdouga Date 2014-05-09 Time 13:45 Sent To  
Notes
2014-05-09 18:18:51RED-LINED THE PLANS.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-01-13 Cont ID  
Sent By rmcdouga Date 2014-01-13 Time 11:55 Rev Time 0.00
Received By rmcdouga Date 2014-01-13 Time 09:22 Sent To  
Notes
2014-01-13 09:23:332010 FBC / 2008 NEC
  
 DENIED BY ELECTRICAL
  
 1) THE ELECTRICAL PANEL LOCATED NEXT TO THE KITCHEN
 SINK IS REQUIRED TO BE RE-LOCATED (IT CAN BE REVERSED
 TO FACE TOWARD THE LIVING ROOM). NEC 240.24(A)
  
 2) AN ELECTRICAL RECEPTACLE OUTLET IS REQUIRED WITHIN
 25 FEET OF EACH A/C CONDENSERS FOR SERVICE. NEC 210.63
  
 3) THE BATHROOM AND KITCHEN RECEPTACLES SERVICING THE
 COUNTERTOPS ARE REQUIRED TO BE GFCI PER NEC 210.8.
  
 4) RECEPTACLE OUTLET SPACING IN THE UNITS IS REQUIRED
 TO COMPLY WITH NEC 210.52.
  
 5) TAMPER RESISTANT RECEPTACLES ARE REQUIRED PER NEC
 406.11.
  
 6) AFCI PROTECTION IS REQUIRED PER 210.12.
  
 7) THE REQUIRED SMOKE ALARM IS NOT SHOWN FOR THE NEWLY
 CREATED BEDROOM. FBC R314.
  
 NOTE: PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW
 EACH OF THE REVIEW COMMENTS HAS BEEN ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-05-09 Cont ID  
Sent By rmcdouga Date 2014-05-09 Time 18:54 Rev Time 0.00
Received By rmcdouga Date 2014-04-24 Time 11:37 Sent To  
Notes
2014-05-02 11:38:19SENT TO R MCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-01-13 Cont ID  
Sent By rmcdouga Date 2014-01-13 Time 16:53 Rev Time 0.00
Received By rmcdouga Date 2013-12-02 Time 17:20 Sent To  
Notes
2013-12-02 17:22:27R18

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2014-05-23 Cont ID  
Sent By rmcdouga Date 2014-05-23 Time 17:30 Rev Time 0.00
Received By rmcdouga Date 2014-05-23 Time 17:30 Sent To  
Notes
2014-05-23 17:35:13NO FEES DUE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2014-05-09 Cont ID  
Sent By rmcdouga Date 2014-05-09 Time 18:55 Rev Time 0.00
Received By rmcdouga Date 2014-05-09 Time 18:55 Sent To  
Notes
2014-05-09 18:56:47AN IMPACT FEE REVIEW BY PALM BEACH COUNTY IS REQUIRED.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2014-05-23 Cont ID  
Sent By rmcdouga Date 2014-05-23 Time 16:49 Rev Time 0.00
Received By rmcdouga Date 2014-05-23 Time 16:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2014-05-09 Cont ID  
Sent By rmcdouga Date 2014-05-09 Time 17:00 Rev Time 0.00
Received By rmcdouga Date 2014-05-09 Time 13:45 Sent To  
Notes
2014-05-09 17:03:322010 FBC
  
 DENIED BY MECHANICAL
  
 1) THE ENERGY CALCULATION FORM IS REQUIRED TO BE SIGNED
 AND DATED BY THE OWNER / AGENT. FBC ENERGY SECTION 402
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2014-01-13 Cont ID  
Sent By rmcdouga Date 2014-01-13 Time 07:42 Rev Time 0.00
Received By rmcdouga Date 2014-01-13 Time 07:42 Sent To  
Notes
2014-01-13 09:18:242010 FBC
  
 DENIED BY MECHANICAL
  
 1) SUBMIT TWO SETS OF HVAC EQUIPMENT SIZING
 CALCULATIONS AS REQUIRED BY FBCR M1401.3
  
 2) SUBMIT TWO SETS OF ENERGY CALCULATIONS. FBC ENERGY
 CONSERVATION SECTION 101.4.1
  
 3) SPECIFY THE GRILL SIZE AND CFMS AT EACH OF THE
 SUPPLY OUTLETS. FBCR M1601.1 AND CITY AMENDMENTS
 107.3.5.3
  
 4) SPECIFY THE SIZE OF EACH OF THE GRILLS FOR THE
 RETURN AIR TRANSFER DUCTS ON THE PLANS. FBCR M1602
  
 5) SPECIFY THE SIZE AND LOCATION OF THE RETURN AT THE
 AIR HANDLER CLOSET. IF THE RETURN IS THROUGH A LOUVER
 DOOR SPECIFY THIS ON THE PLANS. FBCR M1602
  
 6) THE TRANSFER DUCT SIZES SPECIFIED ON THE PLANS ARE
 TOO SMALL. FBCR M1602.4 REQUIRES THE TRANSFER DUCTS TO
 BE 1-1/2 TIMES THE CROSS SECTIONAL AREA OF THE SUPPLY
 DUCT ENTERING THE ROOM.
  
 7) PROVIDE AN HVAC EQUIPMENT SCHEDULE ON THE MECHANICAL
 PLANS. SPECIFY THE A/H AND CONDENSER MODEL NUMBERS,
 ELECTRICAL REQUIREMENTS, BREAKER SIZES, TOTAL CFMS,
 HEATING AND COOLING BTUS, ETC.
  
 8) REVISE PLANS TO SHOW A SERVICE RECEPTACLE OUTLET AT
 OR NEAR EACH OF THE CONDENSING UNITS. FBCR M1305.1.4.3
  
 9) ON THE PLANS, PROVIDE AN ANCHORING DETAIL FOR THE
 CONDENSING UNITS THAT IS CAPABLE OF RESISTING A 170 MPH
 WIND SPEED. FBCR M1307.2.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status N Date 2014-05-09 Cont ID  
Sent By rmcdouga Date 2014-05-09 Time 18:51 Rev Time 0.00
Received By rmcdouga Date 2014-05-09 Time 18:51 Sent To  
Notes
2014-05-09 18:52:14NO PLUMBING WORK IS INDICATED ON THE PLANS. SEPARATE
 PERMIT, APPLICATION AND REVIEW IS REQUIRED.

Review Stop Z ZONING
Rev No 1 Status P Date 2013-12-05 Cont ID  
Sent By ajones Date 2013-12-05 Time 15:55 Rev Time 0.00
Received By ajones Date 2013-12-05 Time 15:55 Sent To  
Notes
2013-12-05 15:56:0712/5/13- EXISTING DUPLEX AND VALUE OF PERMIT DOES NOT
 EXCEED 50% OF THE ACCESSED VALUE.