Plan Review Details - Permit 13110759
Plan Review Stops For Permit 13110759
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-01-17 Cont ID  
Sent By skennedy Date 2014-01-17 Time 08:18 Rev Time 0.00
Received By skennedy Date 2014-01-17 Time 08:18 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-12-12 Cont ID  
Sent By rmcdouga Date 2013-12-12 Time 16:06 Rev Time 0.00
Received By rmcdouga Date 2013-12-12 Time 16:06 Sent To  
Notes
2013-12-12 16:08:112010 FBC / 2008 NEC
  
 DENIED BY ELECTRICAL
  
 TWO COMPLETE SETS OF PLANS ARE REQUIRED FOR REVIEW.
 CITY AMENDMENTS 107.1
  
 REVIEWED BY MIKE ALBARRAN

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2013-12-30 Cont ID  
Sent By scaldero Date 2013-12-30 Time 13:25 Rev Time 0.00
Received By scaldero Date 2013-12-30 Time 13:25 Sent To E
Notes
2013-12-30 13:27:48PERMIT #13110759
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PER FBC 904.11.1, A MANUAL ACTIVATION DEVICE SHALL BE
 LOCATED ALONG THE EGRESS PATH AND BE A MINIMUM OF 10
 FEET AND A MAXIMUM OF 20 FEET FROM THE KITCHEN EXHAUST
 SYSTEM. THE DEVICE SHALL BE MOUNTED 42-48 INCHES ABOVE
 THE FLOOR AND SHALL CLEARLY IDENTIFY THE HAZARD
 PROTECTED.
  
 PROVIDE A K-TYPE PORTABLE FIRE EXTINGUISHER AND
 ASSOCIATED SIGNAGE IN KITCHEN AREA.
  
 PROVIDE AN 8 INCH TALL STEEL BAFFLE OR PROVIDE 16
 INCHES OF SPACE BETWEEN THE DEEP FAT FRYER AND SURFACE
 FLAMES OF THE ADJACENT EQUIPMENT.
  
  
 SUE ELLEN CALDERON
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4751
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2013-12-04 Cont ID  
Sent By lphilmor Date 2013-12-04 Time 15:37 Rev Time 0.00
Received By lphilmor Date 2013-12-04 Time 15:37 Sent To M
Notes
2013-12-04 15:42:102510 BROADWAY
 PERMIT # 13110759
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 1. PROVIDE TWO SETS OF PLANS FOR REVIEW.
 2. 18" BAFFLE NEEDED BETWEEN FRYER AND BURNERS.
 3. SEPARATE PLANS FOR HOOD FIRE EXTINGUISHING SYSTEM
 WILL NEED TO BE SUBMITTED.
  
 LAUREN PHILMORE
 FIRE INSPECTOR II / INVESTIGATOR I
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4783
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-01-17 Cont ID  
Sent By skennedy Date 2014-01-17 Time 08:18 Rev Time 0.00
Received By skennedy Date 2013-12-30 Time 10:51 Sent To  
Notes
2014-01-15 17:52:551/15 TO HM DESK
  
2013-12-30 10:52:31SENT TO FIRE BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-12-12 Cont ID  
Sent By rmcdouga Date 2013-12-12 Time 16:02 Rev Time 0.00
Received By rmcdouga Date 2013-11-22 Time 18:25 Sent To  
Notes
2013-11-22 18:26:08TO FIRE BIN

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2014-01-17 Cont ID  
Sent By hmoser Date 2014-01-17 Time 07:26 Rev Time 0.00
Received By hmoser Date 2014-01-16 Time 15:22 Sent To  
Notes
2014-01-17 07:26:34PASS PROVISO
 REFER TO SECTION 304.11 GUARDS 2010 FBC ( M)
 REFER TO SECTION 506.3.12.3 TERMINATION LOCATION
 2010 FBC (M)
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2013-12-12 Cont ID  
Sent By mricard Date 2013-12-12 Time 15:54 Rev Time 0.00
Received By mricard Date 2013-12-12 Time 15:30 Sent To  
Notes
2013-12-12 15:53:44ONLY ONE SET OF PLANS IN THE PKG. SECOND PLAN IS FOR
 LAKE WORTH A/C