Plan Review Details - Permit 13110608
| Plan Review Stops For Permit 13110608 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-01-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-01-04 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-01-04 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-12-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-12-09 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-12-09 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2013-12-09 09:06:12 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS | | | FS471. | | | | | | 2. DOCUMENTS PREPARED BY AN ARCHITECT AND SUBMITTED FOR | | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS | | | FS481. | | | | | | 3. SEE FBC 1603.1.4 AND INCLUDE REQUIRED INFORMATION | | | FOR WIND DESIGN CRITERIA. WIND DESIGN CRITERIA NOT | | | CLEAR AS IT STATES THAT THIS COMPLIES WITH ASCE 7-10 | | | AND FBC 2010, 146MPH. THIS PARCEL IS LOCATED IN 170MPH | | | ULTIMATE. | | | | | | 4. THIS PARCEL IS LOCATED IN EXPOSURE C, FBC 1609, | | | REVISE PLAN. | | | | | | 5. NOTES MAKE REFERENCE TO A RESIDENTIAL BUILDING, BUT | | | PAPA RECORDS SHOW A COMMERCIAL BUILDING AT THIS | | | LOCATION. | | | | | | 6. FLORIDA STATE OR LOCAL PRODUCT APPROVALS REQUIRED | | | FOR ALL COMPONENTS & CLADDING, FAC9N-3. THEY ARE TO BE | | | REVIEWED BY DESIGNER OF RECORD PRIOR TO SUBMITTAL FBC | | | 107. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-12-06 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-01-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-01-10 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-12-20 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2014-01-04 15:02:26 | 1/4 TO ZONING | | | | | | AS OLD SHEETS WERE REMOVED FROM THE PACKAGE, ZONING | | | REVIEW REQUIRED | | | | | | | | 2013-12-20 10:10:11 | SENT TO S HILL DESK. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-12-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-12-09 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-11-19 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2013-11-19 12:28:21 | INCOMING SENT TO ZONING BOX. JW |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-11-22 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2013-11-22 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2013-11-22 |
Time |
10:14 |
Sent To |
B |
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy