Plan Review Details - Permit 13110548
Plan Review Stops For Permit 13110548
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-11-21 Cont ID  
Sent By jwitmer Date 2013-11-21 Time 17:28 Rev Time 0.00
Received By jwitmer Date 2013-11-21 Time 17:02 Sent To  
Notes
2013-11-21 17:14:19BUILDING PLAN REVIEW
 PERMIT: 13110548
 ADD: 811 B BELVEDERE RD
 CONT: CARLOS GONZALEZ
 TEL: (561)601-3585
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. NOV. 21/ 2013
 ACTION: DENIED
  
 1) PLEASE PROVIDE CODE COMPLIANCE FOR THE FOLLOWING:
 2010 FBC-B 1014.2 EGRESS THROUGH INTERVENING SPACES
 4. EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE
 ROOMS, CLOSETS OR SPACES USED FOR SIMILAR PURPOSES.
 EXCEPTIONS:
 2. MEANS OF EGRESS ARE NOT PROHIBITED THROUGH
 STOCKROOMS IN GROUP M OCCUPANCIES WHEN ALL OF THE
 FOLLOWING ARE MET:
  
 2.1. THE STOCK IS OF THE SAME HAZARD CLASSIFICATION AS
 THAT FOUND IN THE MAIN RETAIL AREA;
  
 2.2. NOT MORE THAN 50 PERCENT OF THE EXIT ACCESS IS
 THROUGH THE STOCKROOM;
  
 2.3. THE STOCKROOM IS NOT SUBJECT TO LOCKING FROM THE
 EGRESS SIDE; AND
  
 2.4. THERE IS A DEMARCATED, MINIMUM 44-INCH-WIDE (1118
 MM) AISLE DEFINED BY FULL- OR PARTIAL-HEIGHT FIXED
 WALLS OR SIMILAR CONSTRUCTION THAT WILL MAINTAIN THE
 REQUIRED
 WIDTH AND LEAD DIRECTLY FROM THE RETAIL AREA TO THE
 EXIT WITHOUT OBSTRUCTIONS.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-12-18 Cont ID  
Sent By skennedy Date 2013-12-18 Time 13:38 Rev Time 0.00
Received By skennedy Date 2013-12-18 Time 13:38 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2013-11-20 Cont ID  
Sent By lphilmor Date 2013-11-20 Time 14:25 Rev Time 0.00
Received By lphilmor Date 2013-11-20 Time 14:24 Sent To  
Notes
2013-11-20 14:25:04811 B BELVEDERE RD
  
 PERMIT # 13110548
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 1.THE ADDRESS PROVIDED ON THE PLANS DOES NOT MATCH THE
 ADDRESS PROVIDED ON THE PERMIT APPLICATION.
 2. INDICATE THE OCCUPANCY TYPE FOR THIS LOCATION
 3.PROVIDE A LIFE SAFETY PLAN SHOWING ALL OCCUPANCY
 TYPES, OCCUPANT LOADS, FIRE RATED WALLS, FIRE RATED
 DOORS,EXIT SIGNS, EMERGENCY LIGHTING, TRAVEL DISTANCES,
 COMMON PATH OF TRAVEL ETC.
 4. INDICATE IF BUILDING HAS SPRINKLER PROTECTION.
  
 LAUREN PHILMORE
 FIRE INSPECTOR II / INVESTIGATOR I
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4783
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-12-18 Cont ID  
Sent By skennedy Date 2013-12-18 Time 13:39 Rev Time 0.00
Received By skennedy Date 2013-11-15 Time 09:45 Sent To  
Notes
2013-11-18 09:45:54B18
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2013-12-18 Cont ID  
Sent By skennedy Date 2013-12-18 Time 13:38 Rev Time 0.00
Received By skennedy Date 2013-12-18 Time 13:38 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved