| Plan Review Stops For Permit 13110516 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2013-11-18 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-11-18 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-11-18 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2013-11-18 15:42:50 | ****PROVISO**** | | | ELECTRICAL BONDING | | | 310.1.1 CSST. | | | CORRUGATED STAINLESS STEEL TUBING (CSST) GAS PIPING | | | SYSTEMS SHALL BE BONDED TO THE ELECTRICAL SERVICE | | | GROUNDING ELECTRODE SYSTEM AT THE POINT WHERE THE GAS | | | SERVICE ENTERS THE BUILDING. THE BONDING JUMPER SHALL | | | BE NOT SMALLER THAN 6 AWG COPPER WIRE OR EQUIVALENT. | | | |
|
|