| Plan Review Stops For Permit 13110342 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-02-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-02-08 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-02-08 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2014-02-10 07:28:53 | APPROVED WITH EXCEPTION, REVISION REQUIRED | | | SUBMIT 2 COPIES OF CORRECTED ENERGY CALCULATIONS THAT | | | MATCH PLANS. | | | | | | NOTE: | | | THE STRUCTURE IS LOCATED IN A SPECIAL FLOOD HAZARD | | | AREA, DESIGNATED FLOOD ZONE A5. THE MINIMUM ELEVATION | | | IS 7 FEET BFE PLUS THE ADDITIONAL 6" OF FREEBOARD | | | REQUIRED BY CITY ORDINANCE. BASED ON CITY BUILDING | | | DEPARTMENT RECORDS THE CUMULATIVE TOTAL COSTS OF WORK | | | ON THIS BUILDING INCLUDING $32,000.00 FOR THE PROPOSED | | | WORK IS $ 105,889.00. THE CONTRACTOR SUBMITTED AN | | | APPRAISAL FROM CHARLEEN MCMANUS, SRA, OF ANDERSON & | | | CARR, INC. STATING THE MARKET VALUE OF THE BUILDING | | | IMPROVEMENTS TO BE $ 320,000.00. BECAUSE THE TOTAL OF | | | PREVIOUS IMPROVEMENTS AND THE PROPOSED WORK IS LESS | | | THAN 50 PERCENT OF THE MARKET VALUE, THIS IS NOT | | | CONSIDERED A SUBSTANTIAL IMPROVEMENT. ACCORDING TO THE | | | PROPERTY APPRAISER'S RECORDS THE STRUCTURE WAS BUILT IN | | | 1935 AND HAS HAD NO SUBSTANTIAL IMPROVEMENTS PRIOR TO | | | THE DATE OF THE INITIAL FIRM (MARCH 1, 1979) . | | | THEREFORE THIS IS BUILDING IS CONSIDERED TO BE | | | PRE-FIRM. BASED ON TABLE 6-1A IN FEMA PUBLICATION P-758 | | | NEITHER THE LATERAL ADDITION NOR THE REMODEL IS | | | REQUIRED TO COMPLY WITH NFIP REQUIREMENTS FOR NEW | | | CONSTRUCTION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-01-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-01-31 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-01-30 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2014-01-31 16:07:06 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) SUBMIT TWO SETS OF ENERGY CALCULATIONS FOR THE | | | PROPOSED ADDITION AND AREA BEING CONVERTED TO HABITABLE | | | SPACE AS REQUIRED BY THE 2010 FBC ENERGY CONSERVATION. | | | THE ENERGY FORMS ARE REQUIRED TO BE SIGNED BY THE | | | PREPARER AND THE OWNER/AGENT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] | | | | | | | | | NOTE: | | | THE STRUCTURE IS LOCATED IN A SPECIAL FLOOD HAZARD | | | AREA, DESIGNATED FLOOD ZONE A5. THE MINIMUM ELEVATION | | | IS 7 FEET BFE PLUS THE ADDITIONAL 6" OF FREEBOARD | | | REQUIRED BY CITY ORDINANCE. BASED ON CITY BUILDING | | | DEPARTMENT RECORDS THE CUMULATIVE TOTAL COSTS OF WORK | | | ON THIS BUILDING INCLUDING $32,000.00 FOR THE PROPOSED | | | WORK IS $ 105,889.00. THE CONTRACTOR SUBMITTED AN | | | APPRAISAL FROM CHARLEEN MCMANUS, SRA, OF ANDERSON & | | | CARR, INC. STATING THE MARKET VALUE OF THE BUILDING | | | IMPROVEMENTS TO BE $ 320,000.00. BECAUSE THE TOTAL OF | | | PREVIOUS IMPROVEMENTS AND THE PROPOSED WORK IS LESS | | | THAN 50 PERCENT OF THE MARKET VALUE, THIS IS NOT | | | CONSIDERED A SUBSTANTIAL IMPROVEMENT. ACCORDING TO THE | | | PROPERTY APPRAISER'S RECORDS THE STRUCTURE WAS BUILT IN | | | 1935 AND HAS HAD NO SUBSTANTIAL IMPROVEMENTS PRIOR TO | | | THE DATE OF THE INITIAL FIRM (MARCH 1, 1979) . | | | THEREFORE THIS IS BUILDING IS CONSIDERED TO BE | | | PRE-FIRM. BASED ON TABLE 6-1A IN FEMA PUBLICATION P-758 | | | NEITHER THE LATERAL ADDITION NOR THE REMODEL IS | | | REQUIRED TO COMPLY WITH NFIP REQUIREMENTS FOR NEW | | | CONSTRUCTION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-01-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-01-02 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-12-19 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2014-01-02 10:13:17 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) THE STRUCTURE IS LOCATED IN A SPECIAL FLOOD HAZARD | | | AREA ( FLOOD ZONE A5 ). THE REQUIRED FINISH FLOOR | | | ELEVATION IS 7'-6". BASED ON FEMA REGULATIONS AND THE | | | CITY OF WEST PALM BEACH MUNICIPAL CODE THIS ADDITION IS | | | CONSIDERED A SUBSTANTIAL IMPROVEMENT. (THE VALUE OF THE | | | PROPOSED WORK PLUS PREVIOUS WORK DONE TO THE STRUCTURE | | | EXCEEDS 50 PER CENT OF THE APPRAISED VALUE OF THE | | | STRUCTURE ($ 69,910.00 PER PBC PROPERTY APPRAISER). | | | THEREFORE, THE ADDITION, THE EXISTING STRUCTURE AND THE | | | EQUIPMENT SERVING THEM ARE REQUIRED TO BE AT OR ABOVE | | | THE BASE FLOOD ELEVATION OF 7'-6". SPECIFY THE FINISHED | | | FLOOR ELEVATIONS OF THE EXISTING STRUCTURE AND THE | | | PROPOSED ADDITION ON THE PLANS. IF THE ELEVATIONS ARE | | | BELOW THE REQUIRED MINIMUM 7'-6" BFE INDICATE HOW THIS | | | ISSUE WILL BE ADDRESSED. | | | | | | 2) THE ENGINEER'S SEAL THAT WAS USED IS NOT ACCEPTABLE. | | | AS OF JANUARY 1, 2002, THE WORD CERTIFICATE WAS | | | REQUIRED TO BE REPLACED BY THE WORD LICENSE. FAC | | | 61G15-23.001 | | | | | | 3) THE ONLY ENGINEER'S NAME THAT APPEARS IN THE TITLE | | | BLOCK ON SHEET 4 OF THE PLANS IS RICK BOYETTE. | | | THEREFORE, HE SHOULD SIGN AND SEAL THAT SHEET AS THE | | | DESIGNER OF RECORD FOR THE SCOPE OF WORK INDICATED ON | | | THAT SHEET. FAC 61G-15-23.002 | | | | | | 4) THE EXPOSURE CATEGORY THAT IS SPECIFIED ON THE PLANS | | | IS INCORRECT. BECAUSE THE STRUCTURE IS LOCATED ON THE | | | INTER-COASTAL WATERWAY IT IS EXPOSURE CATEGORY D. FBCR | | | 301.2.1.4 | | | | | | 5) THE COMPONENT AND CLADDING PRESSURES IN THE SCHEDULE | | | ON SHEETS 1 AND 2 NEED TO BE REVISED TO COMPLY WITH | | | EXPOSURE D. FBCR 301.2.1 | | | | | | 6) PROVIDE A STRUCTURAL DETAIL FOR THE EXTERIOR DOOR | | | OPENINGS THAT ARE TO BE FRAMED-IN WHEN THE GARAGE IS | | | CONVERTED TO HABITABLE SPACE. CITY AMENDMENTS 107.2.1.3 | | | | | | 7) THERE IS CONFLICTING INFORMATION ON THE PLANS FOR | | | THE ROOF COVERING. THE ELEVATION DRAWINGS ON SHEETS 1 | | | AND 2 SHOW CONCRETE S-TILE AND THE WALL SECTIONS ON | | | SHEET 7 SPECIFY ASPHALT SHINGLES. PLEASE CLARIFY. CITY | | | AMENDMENTS 107.2.1 | | | | | | 8) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE ROOF | | | COVERING MATERIAL AS REQUIRED BY DCA RULE 9N-3. IF | | | CEMENT S-TILE IS USED INDICATE THE METHOD OF ATTACHMENT | | | THAT WILL BE USED TO INSTALL THE TILE IS CAPABLE OF | | | RESISTING THE REQUIRED OVERTURN MOMENT. FBCR 905.3 IF | | | AN ADHESIVE PRODUCT WILL BE USED, SUBMIT TWO COPIES OF | | | ITS' PRODUCT APPROVAL. | | | | | | 9) SPECIFY THE CONNECTORS THAT WILL BE USED TO SECURE | | | THE OVERHANG FRAMING AT THE GABLE END SHOWN IN THE | | | DETAIL ON SHEET 6. FBCR 801.2 | | | | | | 10) SUBMIT TWO SETS OF ENERGY CALCULATIONS FOR THE | | | CONVERTED GARAGE AND ADDITION. 2010 FBC ENERGY | | | CONSERVATION 101.4.3 | | | | | | 11) THE FLORIDA PRODUCT APPROVAL NUMBERS FOR THE | | | STRUCTURAL CONNECTORS IN THE SCHEDULE ON SHEET 5 ARE | | | INCORRECT. PLEASE UPDATE AND REVISE THE SCHEDULE. DCA | | | RULE 9N-3 | | | | | | 12) ALSO ON SHEET 5, UPDATE REVISE NOTE 10 FROM THE | | | 2005 SIMPSON AND USP CATALOGS TO THE CURRENT ONES. FBCR | | | 301.2.1 | | | | | | 13) PRODUCT APPROVALS WERE SUBMITTED FOR STRUCTURAL | | | MULLIONS. I DID NOT SEE ANYWHERE ON THE PLANS THAT | | | WOULD REQUIRE MULLIONS. PLEASE CLARIFY. CITY AMENDMENTS | | | 107.2.1 | | | | | | 14) THE VALUE SPECIFIED ON THE APPLICATION OF | | | $25,000.00 FOR THE PROPOSED SCOPE OF WORK. PLEASE | | | PROVIDE A DETAILED COST VALUATION AND REFERENCE THE | | | LATEST CITY AMENDMENTS 109.3 | | | | | | 15) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH | | | OF THE REVIEW ITEMS WAS ADDRESSED. THIS WILL HELP | | | REDUCE PLAN REVIEW TIME. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] | | 2013-12-12 17:14:17 | IN BIN R10 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-01-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-01-31 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-01-31 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2014-01-31 09:48:34 | APPROVED WITH EXCEPTION. REDLINED NOTES ON PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-12-12 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2013-12-12 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2013-12-12 |
Time |
15:52 |
Sent To |
B |
|
| Notes |
| 2013-12-12 17:13:23 | THE FOLLOWING ITEMS NEED TO BE ADDRESSED AND CORRECTED | | | ACCORDINGLY: | | | 1. REARRANGE THE OUTLET SPACING TO COMPLY WITH THE | | | REQUIREMENTS OF NEC 210.52 | | | 2. RELOCATE THE ELECTRICAL PANEL AS SHOWN ON THE PLANS | | | TO COMPLY WITH NEC110.26. THE AREA IN FRONT OF THE | | | PANEL HAS TO BE CLEAR ALL THE WAY TO THE FLOOR. | | | 3. AS PER FBC-R314.3.1, SMOKE DETECTOR COMPLIANCE IS | | | REQUIRED THROUGH OUT THE HOME IF NOT ALREADY IN | | | COMPLIANCE. | | | 4. THE LUMINAIRE IN THE ATTIC SHALL HAVE A PROTECTIVE | | | GUARD AS PER NEC 410.11 | | | 5. THE FLOOR PLAN LABELED "EXISTING" REFLECTS AN AHU | | | WHICH APPEARS TO BE RELOCATED AS PART OF THE NEW WORK, | | | INDICATE THE LOCATION OF THE "NEW" AHU AND ITS | | | CORRESPONDING CU. | | | 6. CORRECT THE LOAD TABLE AS SHOWN. MINIMUM OF 2 SMALL | | | APPLIANCE OUTLETS ARE REQUIRED, ONLY ONE INDICATED | | | 7. CORRECT THE RISER DIAGRAM TO MATCH THE LOAD TABLE | | | AND PANEL SCHEDULE AS INTENDED | | | 8. THE NOTE ON THE PL;ANS INDICATE THAT THE EXISTING | | | SERVICE IS BEING UPGRADED TO 200AMP, PROVIDE BETTER | | | DETAIL ON THIS. | | | | | | THIS REVIEW IS NOT INTENDED TO BE A PUNCH LIST FOR THE | | | DESIGN PROFESSIONAL, THEREFORE ADDITIONAL CORRECTIONS | | | MAY BE REQUIRED. A THROUGH REVIEW OF THE PROJECT BY THE | | | DESIGN PROFESSIONAL IS SUGGESTED PRIOR TO THE NEXT | | | SUBMITTAL | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-02-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-02-10 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-02-07 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2014-02-07 17:52:46 | TO RM DESK | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-01-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-01-31 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-01-17 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2014-01-30 10:00:37 | TO R MCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-01-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-01-02 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-11-12 |
Time |
17:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2014-01-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-01-30 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-01-30 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2014-01-30 10:01:47 | MU2014-1074 NO FEES DUE |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2013-12-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-12-30 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-12-30 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2013-12-30 08:29:09 | AN IMPACT FEE REVIEW BY PALM BEACH COUNTY OF ONE OF THE | | | APPROVED SETS OF PLANS WILL BE REQUIRED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2014-02-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-02-08 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-02-08 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2014-02-08 11:28:40 | PER THE GENERAL CONTRACTOR'S REQUEST THE MECHANICAL | | | PERMIT, APPLICATION AND REVIEWS WILL BE DONE AS A | | | SEPARATE PERMIT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2014-01-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-01-30 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-01-30 |
Time |
17:46 |
Sent To |
|
|
| Notes |
| 2014-01-30 17:56:37 | 2010 FBC | | | | | | DENIED BY MECHANICAL | | | | | | 1) SUBMIT TWO SETS OF MECHANICAL PLANS. SPECIFY THE | | | DUCT LAYOUT, SIZES, GRILL SIZES, CFMS AT EACH OUTLET, | | | THE SIZE AND LOCATION OF RETURN GRILLS AND DUCTS. CITY | | | AMENDMENTS 107.3.5.3 | | | | | | 2) PROVIDE AN EQUIPMENT SCHEDULE ON THE PLANS. CITY | | | AMENDMENTS 107.3.5.3 | | | | | | 3) SHOW THE LOCATION OF THE AIR HANDLER AND CONDENSER | | | ON THE PLANS. CITY AMENDMENTS 107.3.5.3 | | | | | | 4) SHOW COMPLIANCE WITH FBCR M1602.4 FOR BALANCED | | | RETURN AIR. | | | | | | 5) SUBMIT TWO COPIES OF EQUIPMENT SIZING CALCULATIONS | | | BASED ON BUILDING LOADS CALCULATED IN ACCORDANCE WITH | | | ACCA MANUAL J OR OTHER APPROVED METHODS. FBCR M1401.3 | | | | | | 6) THE NAME, SIGNATURE AND LICENSE NUMBER OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN IS REQUIRED ON THE PLANS. | | | CITY AMENDMENTS 107.2.1 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2013-12-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-12-31 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-12-30 |
Time |
18:11 |
Sent To |
|
|
| Notes |
| 2013-12-31 17:30:09 | NO MECHANICAL PLANS WERE SUBMITTED AND NO MECHANICAL | | | PERMIT APPLICATION WAS SUBMITTED. A SEPARATE PERMIT, | | | APPLICATION AND REVIEW IS REQUIRED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-01-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-01-31 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-01-30 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2014-01-31 10:38:31 | PLUMBING PLANS HAVE BEEN REDLINED. A REVISED PLUMBING | | | RISER IS REQUIRED TO BE SUBMITTED TO BE REVIEWED AND | | | APPROVED BEFORE THE FINAL PLUMBING INSPECTION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2013-12-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-12-30 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-12-30 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2013-12-30 08:53:02 | 2010 FBC | | | | | | DENIED BI PLUMBING | | | | | | 1) SHEET 7 OF THE PLANS THAT CONTAINS THE PLUMBING | | | RISER IS SIGNED AND SEALED BY THE ENGINEER, HOWEVER, | | | THE ENGINEER'S INFORMATION THAT IS REQUIRED BY FAC | | | 61G15-23.002 TO BE IN THE TITLE BLOCK IS MISSING. | | | PLEASE CORRECT. | | | | | | 2) BOTH OF THE TUBS ARE SHOWN CONNECTING TO A VENT | | | STACK ABOVE THE ABOVE THE LAVATORIES WHICH IS NOT | | | POSSIBLE UNLESS THEY WERE LOCATED ON THE FLOOR ABOVE. | | | THEY SHOULD CONNECT TO THE HORIZONTAL DRAIN DOWN STREAM | | | FROM THE VENT. PLEASE CORRECT. CITY AMENDMENTS 107.2.1 | | | | | | 3) THE MINIMUM SIZE FOR A WASHING MACHINE DRAIN IS 2" | | | PER FBCR P3201.7. THE PLANS HAVE 1-1/2" PLEASE CORRECT. | | | | | | 4) THE MINIMUM SIZE FOR A BATHTUB IS 1-1/2" PER FBCR | | | P3201.7. THE PLANS HAVE 1-1/4" PLEASE CORRECT. | | | | | | 5) THE STAND PIPE FOR THE CLOTHES WASHING MACHINE SHALL | | | EXTEND A MINIMUM OF 18 INCHES AND A MAXIMUM OF 42 | | | INCHES ABOVE THE TRAP WEIR. FBCR P2706.2 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2014-01-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-01-31 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-01-31 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2014-01-31 14:40:41 | ROOFING PRODUCT APPROVALS THAT WERE SUBMITTED. SANTAFE | | | TILE CORP. HANDMADE BARREL CLAY ROOF TILE - NOA NO. | | | 12-1210.03 AND 3M COMPANY AH-160 ROOF TILE ADHESIVE NOA | | | NO. 13-0502.02 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-11-19 |
|
|
Cont ID |
|
| Sent By |
Dkittred |
Date |
2013-11-19 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2013-11-19 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2013-11-19 11:18:27 | 11/19/13 |
|
|