Plan Review Details - Permit 13110251
| Plan Review Stops For Permit 13110251 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-11-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-11-12 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-11-12 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2013-11-12 14:07:54 | 11/8/13. TALKED TO ENGINEER. JOSEPH FRANK MINCUZZI. HE | | | SAID GARAGE OPENING IS CONSIDERED AS ENCLOSED BUILDING. | | | SEE LOCATION KEY PLAN SUBMITTED. JG. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-11-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-11-07 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-11-07 |
Time |
17:40 |
Sent To |
|
|
| Notes |
| 2013-11-07 18:11:36 | CONDOMINIUM (R2) ALTERATION, BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- BUILDING CONTRACTOR CAN NOT PERFORM ANY STRUCTURAL | | | WORK ON BUILDINGS THAT EXCEED THREE STORIES IN HEIGHT. | | | SEC. 489.105(3)(B) OF FLORIDA STATUTE. NEED GC TO APPLY | | | FOR THIS PERMIT AND REVISE THE NOTICE OF COMMENCEMENT | | | ACCORDINGLY. | | | | | | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR THE GARAGE DOOR TO BE INSTALLED. | | | | | | 3- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) THE GARAGE DOOR PRODUCT | | | APPROVAL AS REQUIRED BY SEC. 107.3.4.1 OF CITY | | | AMENDMENTS TO FBC. | | | | | | 4- ENGINEER'S DRAWING IS MISSING THE FOLLOWING: | | | A) ALL THE WIND DESIGN DATA REQUIRED BY SEC. 1603.1.4 | | | OF FBC-2010. (***NOTE: THIS BUILDING IS LOCATED IN | | | EXPOSURE "D". SEE SEC. 1609.4.3 OF 2010 FBC). | | | | | | B) KEY PLAN SHOWING THE LOCATION/AREA OF WORK IN THE | | | BUILDING. SEC. 107.2.1 OF CITY AMENDMENTS TO FBC. | | | | | | C) ENGINEER TO PROVIDE HIS NAME, LICENSE NUMBER AND | | | ENGINEERING BUSINESS CERTIFICATE OF AUTHORIZATION | | | NUMBER (O'DONNELL, NACCARATO, MIGNOGNA & JACKSON, INC.) | | | AS REQUIRED BY SEC. 61G15-23.002(2) OF FLORIDA | | | ADMINISTRATIVE CODE AND CHAPTER 471 FLORIDA STATUTE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-11-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-11-12 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-11-12 |
Time |
14:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-11-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-11-07 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-11-07 |
Time |
17:40 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |