Plan Review Details - Permit 13110145
Plan Review Stops For Permit 13110145
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2013-11-18 Cont ID  
Sent By jwitmer Date 2013-11-18 Time 06:59 Rev Time 0.00
Received By jwitmer Date 2013-11-18 Time 06:29 Sent To  
Notes
2013-11-18 07:00:17BUILDING PROVISO:
 1) ADDRESS CORRECTED ON PLANS TO 1741 PALM BEACH LAKES
 BLVD # E-223
  
 2) PB OUTLET MALLS:
 A LETTER FROM THE QUALIFIER OF BOTH THE SHELL
 CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT
 CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT
 PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT
 CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK
 HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY
 WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE
 DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER AND
 NOTARIZED.
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-12-10 Cont ID  
Sent By skennedy Date 2013-12-10 Time 15:49 Rev Time 0.00
Received By skennedy Date 2013-12-10 Time 15:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-11-25 Cont ID  
Sent By skennedy Date 2013-11-25 Time 11:17 Rev Time 0.00
Received By skennedy Date 2013-11-25 Time 10:25 Sent To  
Notes
2013-11-25 11:18:00PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 FBC 107.3.5.1.6 ENERGY CALCULATIONS - PROVIDE AN ENERGY
 SUBMITTAL COMPLIANT WITH FBC-E 103
 FBC-E 505.2.2 PROVIDE AUTOMATIC LIGHTING SHUTOFF
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2013-11-13 Cont ID  
Sent By scaldero Date 2013-11-13 Time 16:45 Rev Time 0.00
Received By scaldero Date 2013-11-13 Time 16:35 Sent To  
Notes
2013-11-13 16:45:34PERMIT #13110145
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING
 DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A
 FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN
 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE
 PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST
 BE SUBMITTED BY EMAIL ([email protected])
 ([email protected]) OR IN WRITING (FAX: 561-804-4774) AND
 APPROVED BY THE OFFICE OF THE FIRE MARSHAL LOCATED AT
 500 NORTH DIXIE HIGHWAY.
  
 ENTRY DOORS: THUMB-TURN LOCK TO BE EQUIPPED WITH A
 LOCK/UNLOCK INDICATOR.
  
 EACH FIRE BARRIER SHALL BE PERMANENTLY IDENTIFIED WITH
 SIGNS OR STENCILING READING FIRE BARRIER-PROTECT ALL
 OPENINGS. CHARACTERS SHALL BE AT LEAST 4-INCHES IN
 HEIGHT AND HALF-INCH IN WIDTH. IDENTIFICATION SHALL BE
 SPACED NOT MORE THAN 15 FEET ON CENTER.
  
 PROVIDE 44 INCH WIDE STRIPING (DEMARCATION) IN
 STOREROOM TO ENSURE EGRESS PATH REQUIREMENTS ARE
 MAINTAINED AT ALL TIMES.
  
 AN APPROVED WRITTEN EMERGENCY PLAN FOR THE EMERGENCY
 EGRESS OF OCCUPANTS IS REQUIRED PRIOR TO OCCUPANCY. ALL
 EMPLOYEES SHALL BE INSTRUCTED AND PERIODICALLY DRILLED
 WITH RESPECT TO THEIR DUTIES UNDER THE PLAN.
  
 EMPLOYEES SHALL BE PERIODICALLY TRAINED OR INSTRUCTED
 IN THE USE OF PORTABLE FIRE EXTINGUISHERS.
  
 SUB-PERMITS REQUIRED FOR ALL WORK DONE RELATED TO THE
 FIRE ALARM AND SPRINKLER SYSTEM.
  
 WHERE MUSIC SYSTEMS ARE BEING INSTALLED IN TENANT
 SPACES: THE SPEAKER SYSTEM WILL NEED TO BE TESTED
 AGAINST THE FIRE ALARM SYSTEM TO ENSURE THAT THE
 MINIMUM REQUIRED DECIBEL LEVELS OF THE FIRE ALARM
 SYSTEM ARE BEING MET. PENDING RESULTS OF FIELD
 INSPECTION/FIRE ALARM TEST, ADDITIONAL REQUIREMENTS MAY
 BE NEEDED.
  
 SUE ELLEN CALDERON
 FIRE INSPECTOR & INVESTIGATOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4751
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-12-10 Cont ID  
Sent By skennedy Date 2013-12-10 Time 15:50 Rev Time 0.00
Received By skennedy Date 2013-12-09 Time 18:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-11-26 Cont ID  
Sent By shill Date 2013-11-26 Time 10:07 Rev Time 0.00
Received By shill Date 2013-11-05 Time 17:49 Sent To  
Notes
2013-11-25 11:18:20SENT TO EZ
2013-11-06 17:50:11B13

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2013-11-23 Cont ID  
Sent By jwitmer Date 2013-11-23 Time 09:42 Rev Time 0.00
Received By jwitmer Date 2013-11-23 Time 09:42 Sent To  
Notes
2013-11-23 09:43:28IMPACT FEES NOT REQUIRED ON THE BASE BUILDING GROUP "J"
 CREDIT USE AT PBC. JW

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2013-12-10 Cont ID  
Sent By skennedy Date 2013-12-10 Time 15:49 Rev Time 0.00
Received By skennedy Date 2013-12-10 Time 15:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2013-11-23 Cont ID  
Sent By jwitmer Date 2013-11-23 Time 09:56 Rev Time 0.00
Received By jwitmer Date 2013-11-23 Time 09:43 Sent To  
Notes
2013-11-23 09:56:16MECHANICAL PLAN REVIEW
 PERMIT: 13110145
 ADD: 1741 PALM BEACH LAKES # E223
 CONT: TBD
 CONTACT: KARI NEVILLE
 TEL: (561) 373-3902
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 1ST REVIEW
 DATE: SAT. NOV. 23/ 2013
 ACTION: DENIED
  
 1) PLEASE PROVIDE THE MISSING ENERGY CALCULATIONS. 2010
 FBC-ENEREGY 103.1 GENERAL.
 CONSTRUCTION DOCUMENTS AND OTHER SUPPORTING DATA SHALL
 BE SUBMITTED IN ONE OR MORE SETS WITH EACH APPLICATION
 FOR A PERMIT. THE CONSTRUCTION DOCUMENTS SHALL BE
 PREPARED BY A REGISTERED DESIGN PROFESSIONAL WHERE
 REQUIRED BY FLORIDA STATUTES. WHERE SPECIAL CONDITIONS
 EXIST, THE CODE OFFICIAL IS AUTHORIZED TO REQUIRE
 NECESSARY CONSTRUCTION DOCUMENTS TO BE PREPARED BY A
 REGISTERED DESIGN PROFESSIONAL.
 103.2 INFORMATION ON CONSTRUCTION DOCUMENTS.
 103.2.1 CODE DEMONSTRATION FORMS.
 SEE TABLE 103.2.1. FORM 506 (COMMISISSION APPROVED
 SOFTWARE PRINTOUT).
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2013-12-10 Cont ID  
Sent By skennedy Date 2013-12-10 Time 15:50 Rev Time 0.00
Received By skennedy Date 2013-12-10 Time 15:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2013-11-22 Cont ID  
Sent By lwagner Date 2013-11-22 Time 10:24 Rev Time 0.00
Received By lwagner Date 2013-11-19 Time 15:23 Sent To  
Notes
2013-11-22 10:24:40FBC 2010 ACCESSIBILITY CODE
 FBC 2010 PLUMBING REVIEW #1
 DENIED:
  
  
 1. THE COMMON AREA TOILET FACILITIES ARE OVER 500' FROM
 THE STORE ENTRANCE. PLEASE VERIFY THE PUBLIC ACCESS
 DISTANCE WITH THE PALM BEACH OUTLET MALL. ALSO THE
 ROUTE TO THE STORE FACILITIES APPEARS TO BE THROUGH A
 STORAGE (STOCK) AREA. SHEET A0.01 LISTS THE NON SALES
 AREA AS A STOCKROOM. THE RESTROOMS WILL BE REQUIRED TO
 BE OPEN TO PUBLIC ACCESS.
  
 403.3.2 LOCATION OF TOILET FACILITIES IN OCCUPANCIES
 OTHER THAN COVERED MALLS.
 IN OCCUPANCIES OTHER THAN COVERED MALL BUILDINGS, THE
 REQUIRED PUBLIC AND EMPLOYEE TOILET FACILITIES SHALL BE
 LOCATED NOT MORE THAN ONE STORY ABOVE OR BELOW THE
 SPACE REQUIRED TO BE PROVIDED WITH TOILET FACILITIES,
 AND THE PATH OF TRAVEL TO SUCH FACILITIES SHALL NOT
 EXCEED A DISTANCE OF 500 FEET (152 M).
  
 403.3.1 ACCESS.
 THE ROUTE TO THE PUBLIC TOILET FACILITIES REQUIRED BY
 SECTION 403.3 SHALL NOT PASS THROUGH KITCHENS, STORAGE
 ROOMS OR CLOSETS. ACCESS TO THE REQUIRED FACILITIES
 SHALL BE FROM WITHIN THE BUILDING OR FROM THE EXTERIOR
 OF THE BUILDING. ALL ROUTES SHALL COMPLY WITH THE
 ACCESSIBILITY REQUIREMENTS OF THE FLORIDA BUILDING
 CODE, ACCESSIBILITY. THE PUBLIC SHALL HAVE ACCESS TO
 THE REQUIRED TOILET FACILITIES AT ALL TIMES THAT THE
 BUILDING IS OCCUPIED.
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  

Review Stop POLICE POLICE
Rev No 1 Status N Date 2013-12-10 Cont ID  
Sent By skennedy Date 2013-12-10 Time 15:49 Rev Time  
Received By skennedy Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2013-11-25 Cont ID  
Sent By eschneid Date 2013-11-25 Time 21:33 Rev Time 0.25
Received By eschneid Date 2013-11-25 Time 21:33 Sent To B
Notes
2013-11-13 15:20:4211/13/13