Plan Review Details - Permit 13101110
Plan Review Stops For Permit 13101110
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2014-01-14 Cont ID  
Sent By jwitmer Date 2014-01-14 Time 17:50 Rev Time 0.00
Received By jwitmer Date 2014-01-14 Time 17:04 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2014-01-02 Cont ID  
Sent By JWITMER Date 2013-12-19 Time 13:51 Rev Time 0.00
Received By jwitmer Date 2013-12-19 Time 06:34 Sent To  
Notes
2013-12-19 07:54:34BUILDING PLAN REVIEW
 PERMIT: 13101110
 ADD: 415 9TH ST
 CONT: RECORD CONSTRUCTION
 TEL: (561)662-2775
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: THURSDAY DEC 19/2013
 ACTION: DENIED
  
 1) COMPLIED.
  
 2) COMPLIED.
  
 3) 2ND REQUEST. 703.4 INTERIOR FINISH. THE INTERIOR
 FINISH OF WALLS AND CEILINGS IN EXITS AND CORRIDORS IN
 ANY WORK AREA SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING. SEE 2010 FBC-B TABLE
 803.9.
 EXCEPTION: EXISTING INTERIOR FINISH MATERIALS THAT DO
 NOT COMPLY WITH THE INTERIOR FINISH REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING. SHALL BE PERMITTED TO
 BE TREATED WITH AN APPROVED FIRE-RETARDANT COATING IN
 ACCORDANCE WITH THE MANUFACTURER?S INSTRUCTIONS TO
 ACHIEVE THE REQUIRED RATING.
  
 4) 705.2 GENERAL. THE MEANS OF EGRESS SHALL COMPLY WITH
 THE REQUIREMENTS OF THIS SECTION. EXCEPTIONS:
 1. WHERE THE WORK AREA AND THE MEANS OF EGRESS SERVING
 IT COMPLIES WITH THE FLORIDA FIRE PREVENTION CODE.
 2. MEANS OF EGRESS CONFORMING TO THE REQUIREMENTS OF
 THE FLORIDA BUILDING CODE, BUILDING AND THE FLORIDA
 FIRE PREVENTION CODE UNDER WHICH THE BUILDING WAS
 CONSTRUCTED SHALL BE CONSIDERED COMPLIANT MEANS OF
 EGRESS IF, IN THE OPINION OF THE CODE OFFICIAL, THEY DO
 NOT CONSTITUTE A DISTINCT HAZARD TO LIFE.
  
 NOTE BOTH SHEET 1 & 2 INDICATE WINDOWS AND OR DOORS ON
 THE 1ST & 2ND FLOOR WITHIN 10 FEET OF THE EXTERIOR
 STAIR, PLEASE SHOW COMPLIANCE WITH THE 2010 FBC-B
 1026.6 EXTERIOR STAIRWAY PROTECTION. NOTE THE PROPOSED
 FIBERGLASS DOOR WILL NEED TO PROVIDE THE 1 HOUR FIRE
 RATING REQUIRED BY 1026.6.
  
 NO PRODUCT APPROVALS WERE SUBMITTED FOR THE INSTALATION
 OF 1 HR FIRE RATED GLASS BLOCK, DOES IT REQUIRE A METAL
 FRAME.
  
 THE PRODUCT APPROVALS SUBMITTED FOR EXTERIOR DOORS WAS
 A DUNBARTON REDIFLEX TWO PIECE STEEL FRAME AND TRINITY
 OPAQUE FIBERGLASS DOOR, THE PRODUCT APPROVAL DOES NOT
 INDICATE TESTING FOR 1 HOUR FIRE RATING OF DOOR.
  
 5-7) COMPLIED.
  
 NEW COMMENT:
  
 8) THE PRODUCT TESTING REPORT SUBMITTED FOR THE PRMIUM
 ATLANTIC ALUMINUM SINGLE HUNG WINDOW IS NEITHER A
 FLORIDA APPROVAL OR MIAMI-DADE NOA, IF SO PLEASE
 PROVIDE THE COVERSHEETS SHOWING IT IS REVIEWED UNDER
 THERE PROGRAMS.
  
 THE PLANS DO NOT INDICATE IF THE EXISTING WINDOW FRAMES
 ARE THE OLD DOUBLE SASH WOOD FRAMES WITH COUNTER WEIGHT
 POCKETS? THE REPORT SUBMITTED INDICATES THEY ARE FOR
 THRU JAMB INSTALATION, DOES THIS MEAN THE OLD EXISTING
 WINDOW FRAMES ARE LEFT INPLACE AND THESE ARE FIT
 DIRECTLY INTO THE EXISTING WINDOW FRAMES, IF SO HOW ARE
 THEY BEING FASTENED THRU TO THE FRAMING WALL MEMBERS?
  
 9) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 10) SHEET A2 INDICATES THIS BUILDING IS A R-3
 OCCUPANCY, R-3 OCCUPANCY IS A ONE AND TWO FAMILY
 OCCUPANCY NOT FOUR UNITS. PLEASE CORRECT. SEE 2010
 FBC-B 310.1.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-11-15 Cont ID  
Sent By jwitmer Date 2013-11-15 Time 15:47 Rev Time 0.00
Received By jwitmer Date 2013-11-15 Time 14:11 Sent To  
Notes
2013-11-15 14:26:47BUILDING PLAN REVIEW
 PERMIT: 13101110
 ADD: 415 9TH ST
 CONT: RECORD CONSTRUCTION
 TEL: (561)662-2775
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRIDAY NOV. 15/ 2013
 ACTION: DENIED
  
 1) THE DESIGNER OF RECORD HAS NOT INDICATED TO WHICH
 METHOD UNDER THE 2010 EXISTING BUILDING CODE THIS
 PROJECT WAS DESIGNED, PLEASE PROVIDE WHICH COMPLIANCE
 METHOD WAS USED IN THE DESIGN. 101.5 COMPLIANCE
 METHODS.
 THE REPAIR, ALTERATION, CHANGE OF OCCUPANCY, ADDITION
 OR RELOCATION OF ALL EXISTING BUILDINGS SHALL COMPLY
 WITH ONE OF THE METHODS LISTED IN SECTIONS 101.5.1
 THROUGH 101.5.3 AS SELECTED BY THE APPLICANT.
 APPLICATION OF A METHOD SHALL BE THE SOLE BASIS FOR
 ASSESSING THE COMPLIANCE OF WORK PERFORMED UNDER A
 SINGLE PERMIT UNLESS OTHERWISE APPROVED BY THE CODE
 OFFICIAL. SECTIONS 101.5.1 THROUGH 101.5.3 SHALL NOT BE
 APPLIED IN COMBINATION WITH EACH OTHER.
  
 2) FOR THE PURPOSE OF THIS REVIEW I WILL BE USING THE
 WORK AREA COMPLIANCE METHOD AND A LEVEL 3 ALTERATION.
 801.2 COMPLIANCE. IN ADDITION TO THE PROVISIONS OF THIS
 CHAPTER, WORK SHALL COMPLY WITH ALL OF THE REQUIREMENTS
 OF CHAPTERS 6 AND 7. THE REQUIREMENTS OF SECTIONS 703,
 704, AND 705 SHALL APPLY WITHIN ALL WORK AREAS WHETHER
 OR NOT THEY INCLUDE EXITS AND CORRIDORS SHARED BY MORE
 THAN ONE TENANT AND REGARDLESS OF THE OCCUPANT LOAD.
  
 703.2 VERTICAL OPENINGS. EXISTING VERTICAL OPENINGS
 SHALL COMPLY WITH THE PROVISIONS OF SECTIONS 703.2.1,
 703.2.2, AND 703.2.3.
  
 703.2.1 EXISTING VERTICAL OPENINGS. ALL EXISTING
 INTERIOR VERTICAL OPENINGS CONNECTING TWO OR MORE
 FLOORS SHALL COMPLY WITH THE APPROPRIATE SECTIONS OF
 THE FLORIDA FIRE PREVENTION CODE.
  
 703.2.3 SUPPLEMENTAL STAIRWAY ENCLOSURE REQUIREMENTS.
 WHERE THE WORK AREA ON ANY FLOOR EXCEEDS 50 PERCENT OF
 THAT FLOOR AREA, STAIRWAYS THAT ARE PART OF THE MEANS
 OF EGRESS SERVING THE WORK AREA SHALL, AT A MINIMUM, BE
 ENCLOSED WITH SMOKE-TIGHT CONSTRUCTION ON THE HIGHEST
 WORK AREA FLOOR AND ALL FLOORS BELOW.
  
 3) 703.4 INTERIOR FINISH. THE INTERIOR FINISH OF WALLS
 AND CEILINGS IN EXITS AND CORRIDORS IN ANY WORK AREA
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
 EXCEPTION: EXISTING INTERIOR FINISH MATERIALS THAT DO
 NOT COMPLY WITH THE INTERIOR FINISH REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING. SHALL BE PERMITTED TO
 BE TREATED WITH AN APPROVED FIRE-RETARDANT COATING IN
 ACCORDANCE WITH THE MANUFACTURER?S INSTRUCTIONS TO
 ACHIEVE THE REQUIRED RATING.
  
 4) 705.2 GENERAL. THE MEANS OF EGRESS SHALL COMPLY WITH
 THE REQUIREMENTS OF THIS SECTION. EXCEPTIONS:
 1. WHERE THE WORK AREA AND THE MEANS OF EGRESS SERVING
 IT COMPLIES WITH THE FLORIDA FIRE PREVENTION CODE.
 2. MEANS OF EGRESS CONFORMING TO THE REQUIREMENTS OF
 THE FLORIDA BUILDING CODE, BUILDING AND THE FLORIDA
 FIRE PREVENTION CODE UNDER WHICH THE BUILDING WAS
 CONSTRUCTED SHALL BE CONSIDERED COMPLIANT MEANS OF
 EGRESS IF, IN THE OPINION OF THE CODE OFFICIAL, THEY DO
 NOT CONSTITUTE A DISTINCT HAZARD TO LIFE.
  
 NOTE BOTH SHEET 1 & 2 INDICATE WINDOWS AND OR DOORS ON
 THE 1ST & 2ND FLOOR WITHIN 10 FEET OF THE EXTERIOR
 STAIR, PLEASE SHOW COMPLIANCE WITH THE 2010 FBC-B
 1026.6 EXTERIOR STAIRWAY PROTECTION. NOTE THE PROPOSED
 FIBERGLASS DOOR WILL NEED TO PROVIDE THE 1 HOUR FIRE
 RATING REQUIRED BY 1026.6.
  
 5) 705.5 OPENINGS IN CORRIDOR WALLS.
 OPENINGS IN CORRIDOR WALLS IN ANY WORK AREA SHALL
 COMPLY WITH SECTIONS 705.5.1 THROUGH 705.5.4.
  
 EXCEPTION: OPENINGS IN CORRIDORS WHERE SUCH CORRIDORS
 ARE NOT REQUIRED TO BE RATED IN ACCORDANCE WITH THE
 FLORIDA BUILDING CODE, BUILDING.
  
 705.5.1 CORRIDOR DOORS.
  
 705.5.1.1 CORRIDOR DOORS IN THE WORK AREA SHALL NOT BE
 CONSTRUCTED OF HOLLOW CORE WOOD AND SHALL NOT CONTAIN
 LOUVERS.
  
 705.5.1.2 ALL REPLACEMENT DOORS SHALL BE 13/4-INCH (45
 MM) SOLID BONDED WOOD CORE OR APPROVED EQUIVALENT,
 UNLESS THE EXISTING FRAME WILL ACCOMMODATE ONLY A
 13/8-INCH (35 MM) DOOR.
  
 705.5.1.3 ALL DWELLING UNIT, GUESTROOM OR ROOMING UNIT
 CORRIDOR DOORS IN WORK AREAS IN BUILDINGS OF GROUPS
 R-1, R-2, AND I-1 SHALL BE AT LEAST 13/8 -INCH (35 MM)
 SOLID CORE WOOD OR APPROVED EQUIVALENT AND SHALL NOT
 HAVE ANY GLASS PANELS OTHER THAN APPROVED WIRED GLASS
 OR OTHER APPROVED GLAZING MATERIAL IN METAL FRAMES. ALL
 DWELLING UNIT OR SLEEPING UNIT CORRIDOR DOORS IN WORK
 AREAS IN BUILDINGS OF GROUPS R-1, R-2, AND I-1 SHALL BE
 EQUIPPED WITH APPROVED DOOR CLOSERS.
  
 6) 705.9 HANDRAILS.
 THE REQUIREMENTS OF SECTIONS 705.9.1 AND 705.9.2 SHALL
 APPLY TO HANDRAILS FROM THE WORK AREA FLOOR TO, AND
 INCLUDING, THE LEVEL OF EXIT DISCHARGE.
  
 705.9.1 MINIMUM REQUIREMENT. EVERY REQUIRED EXIT
 STAIRWAY THAT IS PART OF THE MEANS OF EGRESS FOR ANY
 WORK AREA AND THAT HAS THREE OR MORE RISERS AND IS NOT
 PROVIDED WITH AT LEAST ONE HANDRAIL, OR IN WHICH THE
 EXISTING HANDRAILS ARE JUDGED TO BE IN DANGER OF
 COLLAPSING, SHALL BE PROVIDED WITH HANDRAILS FOR THE
 FULL LENGTH OF THE RUN OF STEPS ON AT LEAST ONE SIDE.
 ALL EXIT STAIRWAYS WITH A REQUIRED EGRESS WIDTH OF MORE
 THAN 66 INCHES (1676 MM) SHALL HAVE HANDRAILS ON BOTH
 SIDES.
  
 705.9.2 DESIGN. HANDRAILS REQUIRED IN ACCORDANCE WITH
 SECTION 705.9.1 SHALL BE DESIGNED AND INSTALLED IN
 ACCORDANCE WITH THE PROVISIONS OF THE FLORIDA BUILDING
 CODE, BUILDING.
  
 7) 711.1 MINIMUM REQUIREMENTS. ALTERATIONS SUBJECT TO
 THIS CHAPTER SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, ENERGY CONSERVATION.
 502.1.1.1 SHELL BUILDINGS, RENOVATIONS AND ALTERATIONS.
 THE BUILDING THERMAL ENVELOPE SHALL MEET THE
 REQUIREMENTS OF TABLE 502.1.1.1(1) OR TABLE
 502.1.1.1(2). SEE SECTION 101.4.3.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-01-06 Cont ID  
Sent By albarran Date 2014-01-06 Time 11:36 Rev Time 0.00
Received By skennedy Date 2014-01-06 Time 11:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-12-03 Cont ID  
Sent By albarran Date 2013-12-03 Time 09:07 Rev Time 0.00
Received By albarran Date 2013-12-03 Time 09:05 Sent To I
Notes
2013-12-03 09:18:34ON THE FIRST REVIEW OF THE PLANS, THE FOLLOWING
 DEFICIENCIES WERE NOTED:
 1. RELOCATE THE SMOKE DETECTORS AWAY FROM THE CENTER OF
 THE ROOM IN ANTICIPATION OF CEILING FANS.
 2.SHOW SEPARATION BETWEEN UNIT 1 AND THE BASEMENT.
 3. THERE IS AN A/C UNIT INSIDE THE BATHROOM OF UNIT 3.
 4. AS PER FBC-R 303.8,MINIMUM HEATING IS REQUIRED; NO
 MENTION OF WHICH IS ADDRESSED. IF THE WINDOW A/C UNITS
 ARE REVERSIBLE, PLEASE STATE SO AND CORRECT THE
 INDIVIDUAL LOAD CALC ACCORDINGLY.
 5. AS PER NEC 210.52(F), A LAUNDRY CIRCUIT SHALL BE
 PROVIDED IN EACH UNIT UNLESS COMMON LAUNDRY FACILITIES
 ARE ON PREMISES. AGAIN, CORRECT THE DRAWINGS AND THE
 LOAD CALCS AND PANEL SCHEDULES ACCORDINGLY. IF COMMON
 LAUNDRY FACILITIES ARE BEING IMPLEMENTED, ADDRESS SO
 AND MAKE THE NECESSARY CHANGE TO THE HOUSE PANEL AND
 LOAD CALCS.
 6. FOR LIFE SAFETY, MINIMUM LIGHTING SHALL BE PROVIDED
 IN THE ATTIC.
 7. DUE TO THE MISSING LOADS, PROPER LOAD CALCS ARE
 IMPOSSIBLE. PROVIDE CORRECTED LOAD CLACS FOR ROUTE
 CHOSEN INCLUDE THE CORRECTED PANEL SCHEDULES ANDS
 WIRINGS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2014-01-14 Cont ID  
Sent By wjolin Date 2014-01-14 Time 16:10 Rev Time 0.00
Received By wjolin Date 2014-01-14 Time 15:40 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2013-12-21 Cont ID  
Sent By wjolin Date 2013-12-21 Time 11:22 Rev Time 0.00
Received By wjolin Date 2013-12-21 Time 11:13 Sent To  
Notes
2013-12-21 11:14:10415 9TH STREET
 PERMIT #13101110
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 REPEAT COMMENTS:
  
 INDICATE THE PERCENTAGE OF THE BUILDING INVOLVED IN THE
 REHABILITATION. PER NFPA 101 SECTION 43.6.4.1, IN A
 BUILDING WITH REHABILITATION WORK AREAS INVOLVING OVER
 50 PERCENT OF THE AGGREGATE BUILDING AREA, AUTOMATIC
 SPRINKLER SYSTEMS SHALL BE PROVIDED ON THE HIGHEST
 FLOOR CONTAINING A REHABILITATION WORK AREA AND ON ALL
 FLOORS BELOW IN ACCORDANCE WITH THE REQUIREMENTS OF
 OTHER SECTIONS OF THIS CODE APPLICABLE TO NEW
 CONSTRUCTION FOR THE OCCUPANCY.
  
 PER SECTION7.2.2.6.4 (NFPA 101) ALL OPENINGS ADJACENT
 TO AND BELOW AN OUTSIDE STAIR SHALL BE PROTECTED WITH
 AN ASSEMBLY HAVING A MINIMUM 45-MINUTE FIRE PROTECTION
 RATING.
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
  
 WESLEY JOLIN
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2013-11-22 Cont ID  
Sent By wjolin Date 2013-11-22 Time 10:48 Rev Time 0.00
Received By wjolin Date 2013-11-22 Time 09:43 Sent To  
Notes
2013-11-22 10:27:48415 9TH STREET
 PERMIT #13101110
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 INDICATE THE PERCENTAGE OF THE BUILDING INVOLVED IN THE
 REHABILITATION. PER NFPA 101 SECTION 43.6.4.1, IN A
 BUILDING WITH REHABILITATION WORK AREAS INVOLVING OVER
 50 PERCENT OF THE AGGREGATE BUILDING AREA, AUTOMATIC
 SPRINKLER SYSTEMS SHALL BE PROVIDED ON THE HIGHEST
 FLOOR CONTAINING A REHABILITATION WORK AREA AND ON ALL
 FLOORS BELOW IN ACCORDANCE WITH THE REQUIREMENTS OF
 OTHER SECTIONS OF THIS CODE APPLICABLE TO NEW
 CONSTRUCTION FOR THE OCCUPANCY. PER SECTION7.2.2.6.4
 (NFPA 101) ALL OPENINGS ADJACENT TO AND BELOW AN
 OUTSIDE STAIR SHALL BE PROTECTED WITH AN ASSEMBLY
 HAVING A MINIMUM 45-MINUTE FIRE PROTECTION RATING.
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
  
 WESLEY JOLIN
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-01-14 Cont ID  
Sent By jwitmer Date 2014-01-14 Time 17:50 Rev Time 0.00
Received By jwitmer Date 2014-01-09 Time 09:04 Sent To  
Notes
2014-01-11 09:05:56B11
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-01-06 Cont ID  
Sent By skennedy Date 2014-01-06 Time 11:36 Rev Time 0.00
Received By skennedy Date 2013-12-06 Time 17:31 Sent To  
Notes
2013-12-06 17:50:13B13

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-12-05 Cont ID  
Sent By shill Date 2013-12-05 Time 17:57 Rev Time 0.00
Received By shill Date 2013-10-31 Time 17:05 Sent To  
Notes
2013-12-03 09:19:15SENT TO SK FOR PROCESSING
2013-10-31 17:06:02INCOMING SENT TO B-31.JW

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2013-11-05 Cont ID  
Sent By hmoser Date 2013-11-05 Time 14:19 Rev Time 0.00
Received By hmoser Date 2013-11-05 Time 14:17 Sent To  
Notes
2013-11-05 14:19:13PLAN SHOWS A/C WALL UNITS. PERMIT NOT REQUIRED.

Review Stop P PLUMBING
Rev No 2 Status P Date 2013-12-19 Cont ID  
Sent By lwagner Date 2013-12-19 Time 10:34 Rev Time 0.00
Received By lwagner Date 2013-12-19 Time 10:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2013-11-19 Cont ID  
Sent By lwagner Date 2013-11-19 Time 13:27 Rev Time 0.00
Received By lwagner Date 2013-11-19 Time 11:40 Sent To  
Notes
2013-11-19 13:27:14FBC 2010 PLUMBING REVIEW #1
 DENIED:
  
 A WASHING MACHINE CONNECTION IS NOT SHOWN.
 R-2 OCCUPANCIES REQUIRE 1 AUTOMATIC CLOTHES WASHER
 CONNECTION PER 20 DWELLING UNITS.
 P - 403.1 MINIMUM PLUMBING FACILITIES
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  

Review Stop Z ZONING
Rev No 1 Status P Date 2013-12-05 Cont ID  
Sent By aaponte Date 2013-12-05 Time 16:11 Rev Time 0.00
Received By aaponte Date 2013-12-05 Time 16:11 Sent To  
Notes
2013-12-05 16:11:51INTERIOR IMPROVEMENTS AND WINDOW CHANGE. WORK DOES NOT
 EXCEED 50% OF ASSESSED VALUE.
2013-11-13 15:14:3111/13/13