Plan Review Details - Permit 13100982
| Plan Review Stops For Permit 13100982 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-11-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-11-16 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-11-16 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2013-11-16 12:09:45 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. FBC1609, PROVIDE ENGINEERING FOR THE PROPOSED | | | AWNINGS. | | | | | | 2. PROVIDE AWNING FABRIC REMOVAL INSTRUCTIONS TO SHOW | | | COMPLIANCE WITH FBC3105.4.2.1, QUICK RELEASE. THE | | | INSTRUCTIONS SHOULD CONSIST OF A SERIES OF PHOTOGRAPHS. | | | THIS IS TO BE APPROVED BY THE BUILDING OFFICIAL. | | | | | | 3. PER BUILDING OFFICIAL, WE ARE TO PUT ON THE PERMIT | | | FILE A LETTER, OR CONTRACTORS FORM, SIGNED BY THE OWNER | | | (NOT THE TENANT) TO ACKNOWLEDGE THEIR RESPONSIBILITY TO | | | HAVE THE AWNING COVER REMOVED PRIOR TO ANY WIND EVENT | | | WITH PROJECTED WIND SPEEDS OF 75 MPH OR GREATER. THE | | | LETTER/FORM MUST BE SIGNED BY THE OWNER BUT IT NEED NOT | | | BE NOTARIZED. | | | | | | 4. FBC3501.3.5, PROVIDE DOCUMENTATION TO SHOW THAT THE | | | FABRIC MEETS THE REQUIREMENT OF NFPA701. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-11-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-11-16 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-10-28 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2013-10-28 13:24:17 | ROUTED TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-10-30 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2013-10-30 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2013-10-30 |
Time |
14:41 |
Sent To |
B |
|
| Notes |
| 2013-10-30 14:43:10 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) PROVIDE A SURVEY OF THE PROPERTY. IDENTIFY THE | | | LOCATION OF THE AWNINGS ON THE SURVEY. | | | | | | 2.) AWNINGS SHALL NOT PROJECT MORE THAN 4 FT. INTO ANY | | | SETBACK OR BE SUPPORTED BY ANY MEANS OTHER THAN | | | ATTACHMENT TO THE BUILDING. (ZLDR S.94-305(B)(5)) | | | | | | PLEASE NOTE THAT ANY CHANGES ON THE RESUBMITTED PLANS | | | MAY RESULT IN ADDITIONAL COMMENTS. CONTACT LINDA LOUIE | | | @ (561) 822-1442 IF YOU HAVE QUESTIONS. | | | |
|
|
|