Plan Review Details - Permit 13100605
| Plan Review Stops For Permit 13100605 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2013-11-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-11-25 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-11-25 |
Time |
11:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-11-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-11-19 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-11-18 |
Time |
17:33 |
Sent To |
FIRE |
|
| Notes |
| 2013-11-18 17:42:09 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | IT APPEARS ENGINEER IS ELECTING TO USE FBC 2010 | | | EXISTING BUILDING 303.1, PRESCRIPTIVE COMPLIANCE | | | METHODS). | | | | | | THEREFORE, ALL COMMENTS WILL REFER TO FBC 2010 PER FBC | | | 2010 EXISTING BUILDING, ALTERATIONS SHALL COMPLY WITH | | | THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, | | | BUILDING. | | | | | | SEE FBC 704.3 REGARDING PROTECTION OF THE PRIMARY | | | STRUCTURAL FRAME OTHER THAN COLUMNS. ENCASEMENT IS | | | REQUIRED, PLEASE NOTE EXCEPTION. IF USING THE | | | EXCEPTION, NOTE ON THE PLAN. | | | | | | EVEN WITH THE EXCEPTION, THE PROPOSED ALTERATION DOES | | | NOT MAINTAIN ENCASEMENT AS THE PROPOSED ALTERATION | | | PENETRATES THE FIRE RATED ASSEMBLY. ADDITIONALLY, THE | | | PROPOSED ALTERATION IS NOT CONSISTENT WITH THE UL | | | ASSEMBLY REFERENCED. NOTE THAT ENCASEMENT OF STRUCTURAL | | | MEMBERS IN FBC 704 DOES NOT INCLUDE PROVISIONS FOR | | | PENETRATIONS (UNLIKE FIRE WALLS, FIRE BARRIERS, FIRE | | | PARTITIONS). | | | | | | PLEASE FEEL FREE TO CONTACT ME TO DISCUSS. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-10-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-10-19 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-10-19 |
Time |
08:28 |
Sent To |
FIRE |
|
| Notes |
| 2013-10-19 08:36:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. THIS BUILDING WAS CONSTRUCTED AS A FBC 2004 TYPE VA | | | WHICH REQUIRES 1 HOUR FOR ROOF FRAMING. IT IS LIKELY | | | THAT THE CEILING DRYWALL NOTED ON SK-02 "A" IS A PART | | | OF THE RATED ASSEMBLY. | | | | | | SEE FBC 704 AND REVISE PLAN TO SHOW COMPLIANCE. IF | | | EXCEPTIONS ARE USED, PLEASE NOTE ON PLAN. SEE ALSO FBC | | | 2010 EXISTING BUILDING 503. | | | | | | AN ATTEMPT WAS MADE TO LOCATE THE FIRE RATED ASSEMBLY | | | FOR THIS AREA; HOWEVER, DUE TO PLAN SIZE, I WAS UNABLE | | | TO LOCATE QUICKLY. IF YOU WISH TO OBTAIN A SET OF | | | PLANS, PLEASE SUBMIT A RECORDS RESEARCH REQUEST TO | | | [email protected] OR [email protected] | | | | | | 2. REVISE PLAN TO INCLUDE COMPLIANCE METHOD FOR | | | ALTERATION, SEE FBC 2010 EXISTING BUILDING 101.5. | | | COMPLIANCE METHOD NOT CLEAR SO CODES REFERENCED MAY NOT | | | BE CORRECT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-10-28 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2013-10-28 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2013-10-28 |
Time |
11:17 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2013-10-22 |
|
|
Cont ID |
|
| Sent By |
lphilmor |
Date |
2013-10-22 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
lphilmor |
Date |
2013-10-22 |
Time |
09:54 |
Sent To |
E |
|
| Notes |
| 2013-10-22 09:56:23 | 1611 WORTHINGTON ROAD | | | PERMIT #13100605 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | THE ADDRESS PROVIDED ON THE PLANS DOES NOT MATCH THE | | | ADDRESS PROVIDED ON THE PERMIT APPLICATION | | | | | | SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | | | | | | | LAUREN PHILMORE | | | FIRE INSPECTOR II / INVESTIGATOR I | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4783 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-11-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-11-25 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-11-13 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2013-11-13 08:58:10 | INCOMING SENT TOSAMANTHAS' DESK. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-10-28 |
|
|
Cont ID |
|
| Sent By |
jlmitch |
Date |
2013-10-28 |
Time |
17:48 |
Rev Time |
0.00 |
| Received By |
jlmitch |
Date |
2013-10-18 |
Time |
17:29 |
Sent To |
|
|
| Notes |
| 2013-10-18 17:29:28 | TO SH DESK | | | |
|
|
|