| Plan Review Stops For Permit 13100473 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2013-12-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-12-20 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-12-20 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-11-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-11-23 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-11-23 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2013-11-23 09:09:07 | BUILDING PLAN REVIEW | | | PERMIT: 13100473 | | | ADD: 1741 PALM BEACH LAKES BLVD (SHADE CANOPY | | | STRUCTURES) / BROUGHT IN AS 1801 PBL | | | CONT: EMJ CORP | | | TEL: (423)464-1537 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2ND REVIEW | | | DATE: SAT. NOV. 23/ 2013 | | | ACTION: DENIED | | | | | | THE LISTED ITEMS ARE REQUIRED ON THE PLANS TO CLASSIFY | | | THE STRUTURE AND OCCUPANCY: | | | 1) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION, | | | 107.3.5.1.1 MINIMUM PLAN REVIEW CRITERIA FOR COMMERCIAL | | | BUILDINGS; | | | 1A) MINIMUM BUILDING TYPE: 2010 FBC-B 3102.3 | | | | | | 1B) OCCUPANCY TYPE: A-3 ASSEMBLY USESRECREATION OR | | | OTHER AMUSEMENTAND OR OTHER ASSEMBLY USES NOT | | | CLASSIFIED ELSEWHERE. | | | | | | 2) 2010 FBC-B 3102.3 TYPE OF CONSTRUCTION. | | | NONCOMBUSTIBLE MEMBRANE STRUCTURES SHALL BE CLASSIFIED | | | AS TYPE IIB CONSTRUCTION. NONCOMBUSTIBLE FRAME OR | | | CABLE-SUPPORTED STRUCTURES COVERED BY AN APPROVED | | | MEMBRANE IN ACCORDANCE WITH SECTION 3102.3.1 SHALL BE | | | CLASSIFIED AS TYPE IIB CONSTRUCTION. | | | | | | FLORIDA BUILDING OFFICIALS ASSOCIATION REPORT 6027 / | | | 2004 | | | MAY OR MAY NOT REQUIRE SPRINKLERS IT WILL DEPEND ON | | | WILL THERE BE KIOSK BE UNDER THE CANOPIES, WILL THERE | | | BE SEATING WITH COMBUSTIBLE FURNATURE, WILL THERE BE | | | AUTOMOBILES SHOWED IN UNDER THE VARIOUS KIOSK? | | | NFPA 13, 8.15.7.5 STATES, "SPRINKLERES SHALL BE | | | INSTALLED UNDER ROOFS, CANOPIES, OR PORTE-COCHERES OVER | | | AREAS WHERE COMBUSTIBLES ARE STORED AND HANDLED. ALSO | | | STATES IN CANOPIES UNDER WHICH MEALS ARE SERVED OR | | | PEOPLE ARE SEATED, THE FURNIISHINGS MAY BE COMBUSTIBLE. | | | ANY OF THE FORE GOING COULD TRIGGER THE REQUIREMENT FOR | | | FIRE SPRINKLERS. | | | | | | 3) COMPLIED. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-11-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-11-01 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-11-01 |
Time |
06:31 |
Sent To |
|
|
| Notes |
| 2013-11-01 07:44:47 | | | | | | | BUILDING PLAN REVIEW | | | PERMIT: 13100473 | | | ADD: 1741 PALM BEACH LAKES BLVD (SHADE CANOPY | | | STRUCTURES) / BROUGHT IN AS 1801 PBL | | | CONT: EMJ CORP | | | TEL: (423)464-1537 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 1ST REVIEW | | | DATE: FRI. NOV. 01/ 2013 | | | ACTION: DENIED | | | | | | 1) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION, | | | 107.3.5.1.1 MINIMUM PLAN REVIEW CRITERIA FOR COMMERCIAL | | | BUILDINGS; | | | 1A) MINIMUM BUILDING TYPE: 2010 FBC-B 3102.3 | | | | | | 1B) OCCUPANCY TYPE: A-3 ASSEMBLY USESRECREATION OR | | | OTHER AMUSEMENTAND OR OTHER ASSEMBLY USES NOT | | | CLASSIFIED ELSEWHERE. | | | | | | 2) 2010 FBC-B 3102.3 TYPE OF CONSTRUCTION. | | | NONCOMBUSTIBLE MEMBRANE STRUCTURES SHALL BE CLASSIFIED | | | AS TYPE IIB CONSTRUCTION. NONCOMBUSTIBLE FRAME OR | | | CABLE-SUPPORTED STRUCTURES COVERED BY AN APPROVED | | | MEMBRANE IN ACCORDANCE WITH SECTION 3102.3.1 SHALL BE | | | CLASSIFIED AS TYPE IIB CONSTRUCTION. | | | | | | FLORIDA BUILDING OFFICIALS ASSOCIATION REPORT 6027 / | | | 2004 | | | MAY OR MAY NOT REQUIRE SPRINKLERS IT WILL DEPEND ON | | | WILL THERE BE KIOSK BE UNDER THE CANOPIES, WILL THERE | | | BE SEATING WITH COMBUSTIBLE FURNATURE, WILL THERE BE | | | AUTOMOBILES SHOWED IN UNDER THE VARIOUS KIOSK? | | | NFPA 13, 8.15.7.5 STATES, "SPRINKLERES SHALL BE | | | INSTALLED UNDER ROOFS, CANOPIES, OR PORTE-COCHERES OVER | | | AREAS WHERE COMBUSTIBLES ARE STORED AND HANDLED. ALSO | | | STATES IN CANOPIES UNDER WHICH MEALS ARE SERVED OR | | | PEOPLE ARE SEATED, THE FURNIISHINGS MAY BE COMBUSTIBLE. | | | ANY OF THE FORE GOING COULD TRIGGER THE REQUIREMENT FOR | | | FIRE SPRINKLERS. | | | | | | 3) 2010 FBC-B 3105.3.1 FABRIC USED FOR AWNINGS OR | | | FABRIC-COVERED FRAMES SHALL MEET THE FLAME PROPAGATION | | | PERFORMANCE CRITERIA OF NFPA 701. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2013-10-23 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2013-10-23 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2013-10-23 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2013-10-23 14:37:01 | PERMIT #13100473 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | ********PROVISO*********** | | | CANOPY MATERIAL MUST BE OF AN APPROVED FLAME RESISTANT | | | PRODUCT. FLAME CERTIFICATE MUST BE PROVIDED AT TIME OF | | | FIELD INSPECTION AND IS SUBJECT TO INSPECTOR'S | | | APPROVAL. | | | | | | SUE ELLEN CALDERON | | | FIRE INSPECTOR & INVESTIGATOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4751 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-12-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-12-20 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-12-16 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2013-12-17 14:44:33 | RESUBMITTAL SENT TO J. WITMER'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-12-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-12-16 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-11-20 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2013-11-21 10:10:37 | SENT TO C21 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-11-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-11-01 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-10-15 |
Time |
17:42 |
Sent To |
|
|
| Notes |
| 2013-10-16 17:43:13 | INCOMING SENT TO C-07.JW |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
N |
Date |
2013-12-11 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2013-12-11 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2013-12-11 09:06:10 | PER OF. KELLY CARSILLO |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2013-12-10 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2013-12-10 |
Time |
14:28 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2013-12-10 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2013-11-22 15:06:43 | 11/22/13 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-10-28 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2013-10-28 |
Time |
13:54 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2013-10-28 |
Time |
13:54 |
Sent To |
B |
|
| Notes |
| 2013-10-28 14:12:22 | FAILED | | | | | | 1) PROVIDE AN ELEVATION DIMENSION LINE SHOWING THE | | | ENTIRE HEIGHT OF THE CANOPY STRUCTURE FROM GRADE TO THE | | | TOP OF THE STRUCTURE. | | | | | | 2) PROVIDE INFORMATION ON THE MATERIAL THAT WILL BE | | | COVERING THE CANOPY STRUCTURES. THE ELEVATIONS APPROVED | | | AS PART OF THE LATEST SITE PLAN APPROVAL CALL OUT A | | | PTFE COATED FIBERGLASS SHADE, WHILE THE PERMIT PLANS | | | GENERICALLY STATE "FABRIC CANOPIES" IN THE TITLE BLOCK. | | | | | | PLEASE CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | 2013-10-18 13:20:23 | 10/18/13 |
|
|