| 2013-10-23 13:55:59 | BUILDING PLAN REVIEW |
| | PERMIT: 13100374 |
| | ADD: 2921 N AUSTRALIAN AVE |
| | CONT: DBK INDUSTIES |
| | TEL: (954)581-1994 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: OCT. 23/ 2013 |
| | ACTION: DENIED |
| | |
| | 1) WITHIN THE DOCUMENTS SUBMITTED ARE A REPAIR LIST |
| | FROM WPB FIRE DEPARTMENT AND 2 FLOOR PLANS OF THE |
| | BUILDING. PLEASE IDENTIFY WHERE THESE REPAIRS ARE GOING |
| | TO BE MADE ON THE FLOOR PLAN. |
| | NOTE FOR HANDRAILS AND GAURDRAILS SHOP DRAWINGS WILL BE |
| | REQUIRED AND DESIGNED TO THESE REQUIREMENTS: |
| | 2010 FBC-B: |
| | HANDRAILS FOR STAIRS & RAMPS 1012.2 HEIGHT. |
| | HANDRAIL HEIGHT, MEASURED ABOVE STAIR TREAD NOSINGS, OR |
| | FINISH SURFACE OF RAMP SLOPE, SHALL BE UNIFORM, NOT |
| | LESS THAN 34 INCHES (864 MM) AND NOT MORE THAN 38 |
| | INCHES (965 MM). HANDRAIL HEIGHT OF ALTERNATING TREAD |
| | DEVICES AND SHIP LADDERS, MEASURED ABOVE TREAD NOSINGS, |
| | SHALL BE UNIFORM, NOT LESS THAN 30 INCHES (762 MM) AND |
| | NOT MORE THAN 34 INCHES (864 MM). |
| | |
| | EXCEPTION: HANDRAILS FOR STAIRS NOT REQUIRED TO BE |
| | ACCESSIBLE THAT FORM PART OF A GUARDRAIL MAY BE 42 |
| | INCHES (1067 MM) HIGH. |
| | |
| | 1012.3 HANDRAIL GRASPABILITY. |
| | ALL REQUIRED HANDRAILS SHALL COMPLY WITH SECTION |
| | 1012.3.1 OR SHALL PROVIDE EQUIVALENT GRASPABILITY. |
| | EXCEPTIONS: ACCESSIBLE HANDRAILS SHALL MEET THE |
| | REQUIREMENTS OF THE FLORIDA BUILDING CODE, |
| | ACCESSIBILITY. |
| | |
| | 1012.6 HANDRAIL EXTENSIONS. |
| | HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING |
| | SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN |
| | ADJACENT STAIR FLIGHT OR RAMP RUN. WHERE HANDRAILS ARE |
| | NOT CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL |
| | EXTEND HORIZONTALLY AT LEAST 12 INCHES (305 MM) BEYOND |
| | THE TOP RISER AND CONTINUE TO SLOPE FOR THE DEPTH OF |
| | ONE TREAD BEYOND THE BOTTOM RISER. AT RAMPS WHERE |
| | HANDRAILS ARE NOT CONTINUOUS BETWEEN RUNS, THE |
| | HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING |
| | 12 INCHES (305 MM) MINIMUM BEYOND THE TOP AND BOTTOM OF |
| | RAMP RUNS. THE EXTENSIONS OF HANDRAILS SHALL BE IN THE |
| | SAME DIRECTION OF THE STAIR FLIGHTS AT STAIRWAYS AND |
| | THE RAMP RUNS AT RAMPS. |
| | |
| | RAMPS 2010 ACCESSIBLITY CODE: |
| | 405.9 EDGE PROTECTION. |
| | EDGE PROTECTION COMPLYING WITH 405.9.1 OR 405.9.2 SHALL |
| | BE PROVIDED ON EACH SIDE OF RAMP RUNS AND AT EACH SIDE |
| | OF RAMP LANDINGS. |
| | EXCEPTIONS: |
| | 1. EDGE PROTECTION SHALL NOT BE REQUIRED ON RAMPS THAT |
| | ARE NOT REQUIRED TO HAVE HANDRAILS AND HAVE SIDES |
| | COMPLYING WITH 406.3. |
| | 2. EDGE PROTECTION SHALL NOT BE REQUIRED ON THE SIDES |
| | OF RAMP LANDINGS SERVING AN ADJOINING RAMP RUN OR |
| | STAIRWAY. |
| | 3. EDGE PROTECTION SHALL NOT BE REQUIRED ON THE SIDES |
| | OF RAMP LANDINGS HAVING A VERTICAL DROP-OFF OF 1/2 INCH |
| | (13 MM) MAXIMUM WITHIN 10 INCHES (255 MM) HORIZONTALLY |
| | OF THE MINIMUM LANDING AREA SPECIFIED IN 405.7. |
| | |
| | 405.9.1 EXTENDED FLOOR OR GROUND SURFACE. |
| | THE FLOOR OR GROUND SURFACE OF THE RAMP RUN OR LANDING |
| | SHALL EXTEND 12 INCHES (305 MM) MINIMUM BEYOND THE |
| | INSIDE FACE OF A HANDRAIL COMPLYING WITH 505. |
| | ADVISORY 405.9.1 EXTENDED FLOOR OR GROUND SURFACE. |
| | THE EXTENDED SURFACE PREVENTS WHEELCHAIR CASTERS AND |
| | CRUTCH TIPS FROM SLIPPING OFF THE RAMP SURFACE. |
| | |
| | 2) PLEASE INDICATE ON PLANS WHICH INTERIOR NON-BEARING |
| | WALL IS TO BE DEMOLISHED? 107.2.1.3 ADDITIONAL |
| | INFORMATION IS REQUIRED. |
| | |
| | 3) THE DESIGNER OF THE PLANS IS REQUIRED TO PRINT THEIR |
| | NAME SIGN THEIR NAME AND LICENSE NUMBER ON THE PLANS. |
| | 107.2.1.3. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |