Plan Review Details - Permit 13100302
| Plan Review Stops For Permit 13100302 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-11-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-11-02 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-11-02 |
Time |
09:24 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-11-01 |
|
|
Cont ID |
|
| Sent By |
MCDOUGAL |
Date |
2013-11-01 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-11-01 |
Time |
17:01 |
Sent To |
|
|
| Notes |
| 2013-11-01 18:02:02 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) THIS SCOPE OF WORK IS NOT CONSIDERED A REVISION TO | | | THE STRUCTURE. IT NEEDS TO BE A SEPARATE FENCE PERMIT | | | TYPE. SUBMIT A SEPARATE BUILDING PERMIT APPLICATION FOR | | | A FENCE. THE REVISION NUMBER WILL BE CHANGED TO THE | | | PERMIT NUMBER. | | | | | | 2) PROVIDE STRUCTURAL DETAILS WITH ALL DIMENSIONS | | | SPECIFIED FOR THE COLUMNS AT THE DRIVEWAY. | | | | | | 3) THE DRAWINGS DO NOT SPECIFY THAT THE 16" X 16" | | | COLUMN BLOCKS WILL BE FILLED WITH CONCRETE OR THE | | | REQUIRED STRENGTH OF THE OF IT. PLEASE PROVIDE THIS | | | INFORMATION. | | | | | | 4) THE ENTRY PIER ELEVATION SPECIFIES ONE #5 VERTICAL | | | REINFORCING BAR IN THE 16" SQUARE COLUMN. THIS MAY NOT | | | BE ADEQUATE TO RESIST THE LATERAL WIND LOADS ON THE | | | COLUMNS AND THE ATTACHED GATES. THE NOTE BELOW THE PIER | | | DETAIL SAYS BY ENGINEER AFTER AN ASTERISK. PLEASE HAVE | | | THE PERSON RESPONSIBLE FOR THE STRUCTURAL DESIGN REVIEW | | | THE DRAWINGS AND PROVIDE THEIR NAME AND SIGNATURE ON | | | THE PLANS. | | | | | | 5) PROVIDE THE ELECTRICAL DETAILS INCLUDING WIRE SIZES, | | | CONDUIT DETAIL AND GROUNDING DETAIL ON THE PLANS OR | | | APPLY UNDER A SEPARATE PERMIT. | | | | | | 6) PROVIDE A GAS RISER DIAGRAM ON THE PLAN OR APPLY | | | UNDER A SEPARATE PERMIT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2013-11-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-11-01 |
Time |
18:02 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-11-01 |
Time |
18:02 |
Sent To |
|
|
| Notes |
| 2013-11-01 18:04:26 | NO ELECTRICAL PLANS WERE SUBMITTED. A SEPARATE PERMIT, | | | APPLICATION AND REVIEW IS REQUIRED. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2013-11-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-11-01 |
Time |
18:02 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-11-01 |
Time |
18:02 |
Sent To |
|
|
| Notes |
| 2013-11-01 18:04:50 | NO GAS PLANS WERE SUBMITTED. A SEPARATE PERMIT, | | | APPLICATION AND REVIEW IS REQUIRED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-11-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-11-06 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-11-02 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2013-11-02 09:25:27 | SENT TO ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-11-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-11-01 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-10-09 |
Time |
17:56 |
Sent To |
|
|
| Notes |
| 2013-10-31 19:53:40 | 10/31 TO RM DESK | | | | | 2013-10-09 17:56:26 | SENT TO ZONING SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2013-11-05 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2013-11-05 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2013-11-05 |
Time |
14:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-10-16 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2013-10-16 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2013-10-16 |
Time |
17:31 |
Sent To |
B |
|
| Notes |
| 2013-10-16 17:38:03 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING. RESPOND TO THE COMMENTS | | | IN WRITING AND/OR ON THE PLANS WHERE APPLICABLE: | | | | | | 1.) THE GATE CANNOT EXCEED 4 FT. IN THE REQUIRED FRONT | | | SETBACK. (ZLDR S. 94-302(B)(1)) | | | | | | 2.) ARCHITECTURAL FEATURES MAY EXCEED THE MAXIMUM | | | BUILDING HEIGHT BY 10 PERCENT. | | | | | | PLEASE NOTE THAT ANY REVISIONS MAY RESULT IN ADDITIONAL | | | COMMENTS. CONTACT LINDA LOUIE @ (561) 822-1442 IF YOU | | | HAVE QUESTIONS. | | | |
|
|
|