Plan Review Details - Permit 13100302
Plan Review Stops For Permit 13100302
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-11-02 Cont ID  
Sent By rmcdouga Date 2013-11-02 Time 09:24 Rev Time 0.00
Received By rmcdouga Date 2013-11-02 Time 09:24 Sent To Z
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-11-01 Cont ID  
Sent By MCDOUGAL Date 2013-11-01 Time 17:20 Rev Time 0.00
Received By rmcdouga Date 2013-11-01 Time 17:01 Sent To  
Notes
2013-11-01 18:02:022010 FBC
  
 DENIED BY BUILDING
  
 1) THIS SCOPE OF WORK IS NOT CONSIDERED A REVISION TO
 THE STRUCTURE. IT NEEDS TO BE A SEPARATE FENCE PERMIT
 TYPE. SUBMIT A SEPARATE BUILDING PERMIT APPLICATION FOR
 A FENCE. THE REVISION NUMBER WILL BE CHANGED TO THE
 PERMIT NUMBER.
  
 2) PROVIDE STRUCTURAL DETAILS WITH ALL DIMENSIONS
 SPECIFIED FOR THE COLUMNS AT THE DRIVEWAY.
  
 3) THE DRAWINGS DO NOT SPECIFY THAT THE 16" X 16"
 COLUMN BLOCKS WILL BE FILLED WITH CONCRETE OR THE
 REQUIRED STRENGTH OF THE OF IT. PLEASE PROVIDE THIS
 INFORMATION.
  
 4) THE ENTRY PIER ELEVATION SPECIFIES ONE #5 VERTICAL
 REINFORCING BAR IN THE 16" SQUARE COLUMN. THIS MAY NOT
 BE ADEQUATE TO RESIST THE LATERAL WIND LOADS ON THE
 COLUMNS AND THE ATTACHED GATES. THE NOTE BELOW THE PIER
 DETAIL SAYS BY ENGINEER AFTER AN ASTERISK. PLEASE HAVE
 THE PERSON RESPONSIBLE FOR THE STRUCTURAL DESIGN REVIEW
 THE DRAWINGS AND PROVIDE THEIR NAME AND SIGNATURE ON
 THE PLANS.
  
 5) PROVIDE THE ELECTRICAL DETAILS INCLUDING WIRE SIZES,
 CONDUIT DETAIL AND GROUNDING DETAIL ON THE PLANS OR
 APPLY UNDER A SEPARATE PERMIT.
  
 6) PROVIDE A GAS RISER DIAGRAM ON THE PLAN OR APPLY
 UNDER A SEPARATE PERMIT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2013-11-01 Cont ID  
Sent By rmcdouga Date 2013-11-01 Time 18:02 Rev Time 0.00
Received By rmcdouga Date 2013-11-01 Time 18:02 Sent To  
Notes
2013-11-01 18:04:26NO ELECTRICAL PLANS WERE SUBMITTED. A SEPARATE PERMIT,
 APPLICATION AND REVIEW IS REQUIRED.

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2013-11-01 Cont ID  
Sent By rmcdouga Date 2013-11-01 Time 18:02 Rev Time 0.00
Received By rmcdouga Date 2013-11-01 Time 18:02 Sent To  
Notes
2013-11-01 18:04:50NO GAS PLANS WERE SUBMITTED. A SEPARATE PERMIT,
 APPLICATION AND REVIEW IS REQUIRED.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-11-06 Cont ID  
Sent By rmcdouga Date 2013-11-06 Time 13:50 Rev Time 0.00
Received By rmcdouga Date 2013-11-02 Time 09:10 Sent To  
Notes
2013-11-02 09:25:27SENT TO ZONING

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-11-01 Cont ID  
Sent By rmcdouga Date 2013-11-01 Time 17:21 Rev Time 0.00
Received By rmcdouga Date 2013-10-09 Time 17:56 Sent To  
Notes
2013-10-31 19:53:4010/31 TO RM DESK
  
2013-10-09 17:56:26SENT TO ZONING SHELF FOR REVIEW. JG.

Review Stop Z ZONING
Rev No 2 Status P Date 2013-11-05 Cont ID  
Sent By llouie Date 2013-11-05 Time 14:49 Rev Time 0.00
Received By llouie Date 2013-11-05 Time 14:48 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2013-10-16 Cont ID  
Sent By llouie Date 2013-10-16 Time 17:31 Rev Time 0.00
Received By llouie Date 2013-10-16 Time 17:31 Sent To B
Notes
2013-10-16 17:38:03** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING. RESPOND TO THE COMMENTS
 IN WRITING AND/OR ON THE PLANS WHERE APPLICABLE:
  
 1.) THE GATE CANNOT EXCEED 4 FT. IN THE REQUIRED FRONT
 SETBACK. (ZLDR S. 94-302(B)(1))
  
 2.) ARCHITECTURAL FEATURES MAY EXCEED THE MAXIMUM
 BUILDING HEIGHT BY 10 PERCENT.
  
 PLEASE NOTE THAT ANY REVISIONS MAY RESULT IN ADDITIONAL
 COMMENTS. CONTACT LINDA LOUIE @ (561) 822-1442 IF YOU
 HAVE QUESTIONS.
  