| Plan Review Stops For Permit 13100297 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2014-08-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-26 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-23 |
Time |
15:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2014-08-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-04 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-04 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2014-08-04 16:25:58 | BUILDING PLAN REVIEW | | | PERMIT: 13100297 BOILER BLDG VERTICAL | | | ADD: 6651 N JOG RD | | | CONT: KBR | | | TEL: (561 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 4TH REVIEW | | | DATE: MONDAY AUGUST 04/ 2014 | | | ACTION: DENIED. | | | REVIEWED BY BUILDING OFFICIAL BEFORE FINAL ACTION WAS | | | TAKEN!!!! | | | | | | 1) COMPLIED. SHEET 0647 -300-S6-000 THE WIND DESIGN | | | STATES THAT IT IS DESIGNED TO THE 2010 FBC, THE PLANS | | | DOES NOT STATE IF THE PRESSURES ARE LISTED AS VULT OR | | | VASD? RESPONSE INDICATES THEY ARE VALT. | | | | | | 2) THIS COMMENT IS DEALING WITH WALL PANELS NOT THE FL | | | APPROVAL (FL 12760) WHICH DEALS WITH THE LITE PANEL. | | | PRESSURES ARE LOW FOR THE INTERIOR ZONE # 4 AND END | | | ZONE # 5. BOILER ELEVATION SHEET0648-300-S6-550 | | | PROVIDES THE SPACING OF THE GIRT/ PURLINS AVERAGE | | | BETWEEN 4' & 5' WITH THE EXCEPTION OF THE AT ELEVATION | | | 169 TO 178 THE SPACING DROPS TO 3' BETWEEN PURLINS. THE | | | BUTLER NOA 13-0923.07 BUTLER II WALL PANEL LIST THE | | | INTERIOR WALL ZONES WITH A 5'-0" SPACING BETWEEN THE | | | PURLINS, AND AT THE CORNER ZONES A 2'-6" SPACING. | | | PLEASE SUBMIT THE DESIGN REVIEW FOR THE MULTILE SPANS, | | | THIS PRODUCT APPROVAL ON SHEET # 7 HAS A 3 SPAN AND 4 | | | SPAN WITH ASSOCIATED PRESSURES WHICH ARE STILL LOWER | | | THAN THE PRESSURES FOUND ON SHEET 0647-300-56-000. | | | | | | 3) LITE PANEL. THE PRODUCT APPROVAL SUBMITTED BUTLER FL | | | 12760 BUTLER II LITE PANEL PRESSURES ARE A VASD +52.5/ | | | 52.5. VIEW A INDICATES THAT INTERMEDIATE GIRTS MAY BE | | | REQUIRED IF PRESSURES ARE HIGHER. 2010 FBC-B 1609.1.2 | | | PROTECTION OF OPENINGS, 1609.6.4.41 COMPONENTS & | | | CLADDING. | | | | | | 4) COMPLIED. | | | | | | 5) RESPONSE TO THE ROOFING NOA 10-0901IS THIS WAS THE | | | WRONG PRODUCT APPROVAL SUBMITTED. PLEASE REMOVE THIS | | | NOA FROM THE SUBMITTAL IF NOT TO BE INSTALLED. SHEET | | | 0123-300-S22-026 ROOF REFERANCE SHEET SHOWS THE GIRTS | | | AT 5'-0" AND 4'-8" O. C. PLEASE REVIEW THE SUBMITTED | | | PRODUCT APPROVAL FOR THE ROOF STEEL ROOF PANELS NOA | | | 10-0901.20 SEE SHEET 1 OF 6 THE MAXIMUM PURLIN SPANS | | | ARE EXCEEDED , DEPENDING ON THE SPACING OF THE PURLINS | | | THE PRESSURES MAY OR MAY NOT WORK. ALSO THE PRESSURES | | | ARE LOW EVEN WHEN AND IF THE ASSUMED PRESSURES ARE VULT | | | EVEN AT VASD THEY ARE LOW. | | | | | | 6) UPDATE THE HEAVY STRUCTURES LETTER DATED 1-10-2014 | | | AND ALSO REMOVE THE REFERANCE TO THE ROOF PANEL BUTLER | | | MANUFACTURING NOA 10-0901.20 FROM THE LETTER. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2014-07-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-01 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-01 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2014-07-01 12:32:08 | BUILDING PLAN REVIEW | | | PERMIT: 13100297 BOILER BLDG VERTICAL | | | ADD: 6651 N JOG RD | | | CONT: KBR | | | TEL: (561 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 3RD REVIEW | | | DATE: TUES. JULY 01/ 2014 | | | ACTION: DENIED | | | | | | 1) SHEET 0647 -300-S6-000 THE WIND DESIGN STATES THAT | | | IT IS DESIGNED TO THE 2010 FBC, THE PLANS DOES NOT | | | STATE IF THE PRESSURES ARE LISTED AS VULT OR VASD? | | | PRODUCT APPROVALS ARE LISTED AS VASD. 107.2.1.3 | | | ADDITIONAL INFORMATION REQUIRED. FOR THE PURPOSE OF | | | THIS REVIEW IT IS ASSUMED THE PRESSURES ARE VULT, IF | | | NOT IT IS OF A GREATER CONCERN. | | | | | | 2) BOILER ELEVATION SHEET0648-300-S6-550 PROVIDES THE | | | SPACING OF THE GIRT/ PURLINS AVERAGE BETWEEN 4' & 5' | | | WITH TTHTE EXCEPTION OF THE | | | AT ELEVATION 169 TO 178 THE SPACING DROPS TO 3' BETWEEN | | | PURLINS. THE BUTLER NOA 13-0923.07 BUTLER II WALL PANEL | | | LIST THE INTERIOR WALL ZONES WITH A 5'-0" SPACING | | | BETWEEN THE PURLINS, AND AT THE CORNER ZONES A 2'-6" | | | SPACING. ALSO THE PRESSURES ARE LOW EVEN WHEN AND IF | | | THE ASSUMED PRESSURES ARE VULT EVEN AT VASD THEY ARE | | | LOW. | | | | | | 3) THE PRODUCT APPROVAL SUBMITTED BUTLER FL 12760 | | | BUTLER II LITE PANEL PRESSURES ARE A VASD +52.5/ 52.5 | | | VIEW A INDICATES THAT INTERMEDIATE GIRTS MAY BE | | | REQUIRED IF PRESSURES ARE HIGHER. | | | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 | | | COMPONENTS & CLADDING | | | | | | 4) SHEET 0590 300-A2-101 SHOWS WALL LOUVERS, TO DATE NO | | | PRODUCT APPROVALS WERE SUBMITTED FOR THE STORM PROOF | | | LOUVERS. | | | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 | | | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY | | | AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF | | | PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | | PRODUCT APPROVALS: | | | (31)(A) (C) WALL LOUVERS, | | | | | | 5) SHEET 0123-300-S22-026 ROOF REFERANCE SHEET SHOWS | | | THE GIRTS AT 5'-0" AND 4'-8" O. C. PLEASE REVIEW THE | | | SUBMITTED PRODUCT APPROVAL FOR THE ROOF STEEL ROOF | | | PANELS NOA 10-0901.20 SEE SHEET 1 OF 6 THE MAXIMUM | | | PURLIN SPANS ARE EXCEEDED , DEPENDING ON THE SPACING OF | | | THE PURLINS THE PRESSURES MAY OR MAY NOT WORK. ALSO THE | | | PRESSURES ARE LOW EVEN WHEN AND IF THE ASSUMED | | | PRESSURES ARE VULT EVEN AT VASD THEY ARE LOW. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-04-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-04-25 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-04-16 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2014-04-25 17:03:51 | STEVE, I TELEPHONED MIKE ON 4/16/2014 THAT HE HAD | | | ISSUES WITH THE EXTERIOR VERTICAL PRODUCT APPROVALS AS | | | WELL AS THE ROOFING FRAMING MEMBERS, THERE WAS NO ROOF | | | FRAMING PLANS. I'M COPYING MIKE SINCE I'VE NOT HEARD | | | FROM HIM ON THIS REVISION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-11-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-11-14 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-04-16 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2013-11-14 09:28:27 | BUILDING PLAN REVIEW | | | PERMIT: 13100297 BOILER BLDG VERTICAL | | | ADD: 6651 N JOG RD | | | CONT: KBR | | | TEL: (561 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 1ST REVIEW | | | DATE: THURS. NOV. 14/ 2013 | | | ACTION: DENIED | | | | | | 1) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 2) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING | | | | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) , WALL LOUVERS, PANEL WALLS | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF VENTS, ROOF | | | HATCHES | | | | | | 3) ROOF TOP STAIRS AND GAURDRAILS, 2010 FBC-B 1009.13, | | | 1012, HANDRAILS & 1013.3 GAURDRAILS. | | | | | | JAMES WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL 561-805-6715 | | | E-MAIL: JWITMER @WPB.ORG | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-12-23 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2013-12-23 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2013-12-20 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2013-12-23 08:59:30 | CONDITIONALLY APPROVED BY ELECTRIC PURSUANT TO THE | | | ATTACHED PROVISIOS | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2014-05-21 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-05-21 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-05-21 |
Time |
16:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2014-04-17 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-04-17 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-04-17 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2014-04-17 11:26:16 | 6651 NORTH JOG ROAD - BOILER BUILDING | | | TRACKING #13100297 | | | PERMIT #12040748 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | RESPONSE COMMENT: COULD NOT LOCATE LIFE SAFETY PLANS AS | | | INDICATED IN THE RESPONSE LETTER. PROVIDE PLANS | | | INDICATING THE FIRE RESISTANCE RATING OF THE VERTICAL | | | SHAFTS (EXIT STAIRS, ELEVATORS). A DOOR SCHEDULE HAS | | | BEEN PROVIDED; HOWEVER, NO FLOOR PLANS INDICATING A | | | DOOR TAG COULD BE LOCATED. PROVIDE PLANS INDICATING THE | | | TRAVEL DISTANCE TO EXIT STAIRS. | | | | | | ORIGINAL COMMENT: PROVIDE A LIFE SAFETY PLAN SHOWING | | | ALL EXITS, EXIT SIGNS, FIRE RATED WALLS, EMERGENCY | | | LIGHTING, TRAVEL DISTANCES, COMMON PATH OF TRAVE, FIRE | | | EXTINGUISHERS,L ETC. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2013-11-26 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-11-26 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-11-26 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2013-11-26 14:34:26 | 6651 NORTH JOG ROAD - BOILER BUILDING | | | TRACKING #13100297 | | | PERMIT #12040748 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | SHEET A1-100 IS THE ROOF PLAN; HOWEVER, THERE DO NOT | | | APPEAR TO BE ANY ARCHITECTURAL FLOOR/PLATFORM PLANS | | | PROVIDED BELOW THE ROOF LEVEL. PROVIDE A LIFE SAFETY | | | PLAN SHOWING ALL EXITS, EXIT SIGNS, FIRE RATED WALLS, | | | EMERGENCY LIGHTING, TRAVEL DISTANCES, COMMON PATH OF | | | TRAVE, FIRE EXTINGUISHERS,L ETC. | | | | | | CONFIRM BOILER FURNACES ARE NOT OIL-FIRED; OTHERWISE | | | PER NFPA 850 SECTION 7.5.1.1 BOILER-FURNACES WITH | | | MULTIPLE OIL-FIRED BURNERS OR THAT USE OIL FOR IGNITION | | | SHOULD BE PROTECTED WITH AUTOMATIC SPRINKLER, WATER | | | SPRAY, FOAM, FOAM-WATER SPRINKLER SYSTEMS, OR | | | COMPRESSED AIR FOAM SYSTEMS COVERING THE BURNER FRONT | | | OIL HAZARD. | | | | | | WESLEY JOLIN | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2014-09-10 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-10 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-10 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2014-08-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-26 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-18 |
Time |
07:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2014-08-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-05 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-07-24 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-07-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-07-01 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-06-03 |
Time |
07:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-04-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-04-25 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-03-19 |
Time |
07:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-12-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-12-23 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-10-11 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-09-10 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-10 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-10 |
Time |
16:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2013-11-12 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2013-11-12 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2013-11-12 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2013-11-19 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-11-19 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-11-19 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2013-11-19 09:32:57 | NO PLUMBING FOUND ON PLANS. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2014-09-29 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-29 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-26 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-11-18 |
|
|
Cont ID |
|
| Sent By |
eschenid |
Date |
2013-11-18 |
Time |
12:37 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2013-11-18 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2013-11-13 14:37:30 | 11/13/13 |
|
|