Plan Review Details - Permit 13100137
| Plan Review Stops For Permit 13100137 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-11-12 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2013-11-12 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2013-11-12 |
Time |
15:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-10-28 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2013-10-28 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2013-10-28 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2013-10-28 09:34:17 | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE DESIGN CRITERIA LISTS THE WIND EXPOSURE AS "B," | | | THE ACTUAL EXPOSURE IS "C." | | | 2) DESIGN PRESSURES SHOULD BE CALCULATED AND PROVIDED | | | WITH THE ENGINEERING SUBMITTAL. | | | 3) SHEET 2/3 OF THE ENGINEERING SUBMITTAL PROVIDES | | | ANCHORING DETAILS FOR THE SDG'S ONLY. IT IS UNCLEAR IF | | | THIS IS INTENDED FOR BUCKS, OR THE SGD FRAMES. | | | 4) PURSUANT TO FBC 107.3.4, THE SELECTED WINDOW AND SGD | | | PRODUCT APPROVALS SHALL BE REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD FOR THIS | | | INSTALLATION. | | | 5) ALTHOUGH THE INCLUDED CONTRACT IDENTIFIES THE SIZE | | | AND TYPE OF SELECTED PRODUCTS, A SCHEDULE IS PREFERRED | | | FOR THIS PURPOSE. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-11-07 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2013-11-08 16:59:42 | SENT TO KENNEDY'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-11-08 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2013-10-28 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-10-04 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2013-11-08 16:58:51 | ENTERED "N" STATUS TO CLOSE THIS STOP. REVIEW DONE ON | | | 10/28/13 BY STEVE KENNEDY. JG. | | 2013-10-28 09:35:23 | PLACED IN SMALL DENIED PLANS "C." | | 2013-10-04 11:28:09 | ROUTED TO MISC 1 |
|
|
|