| Plan Review Stops For Permit 13100124 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-03-05 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-03-05 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-10-20 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2014-10-20 14:13:44 | 1) SUBMIT COPIES OF THE APPLICABLE SIZING TABLES USED | | | FOR THE SIZING OF THIS SYSYTEM. WPB AMEND. TO 2010 FBC | | | SEC. 107.2.1. | | | 2) SHOW THE LONGEST LENGTH OF PIPING FROM THE POINT OF | | | DELIVERY TO THE MOST REMOTE OUTLET AND SHOW THE TOTAL | | | BTU LOAD ON THE SYSTEM. 2010 FGC SEC.402.4.1. | | | 3) IDENTIFY THE APPLIANCES ON THE SYSTEM.WPB AMEND. TO | | | 2010 FBC SEC. 107.2.1. | | | 4) SHOW THE PSI OF THE SYSTEM ON THE PLANWPB AMEND. TO | | | 2010 FBC SEC. 107.2.1. | | | 5) SOME OF THE BTU LOADS ARE ILLEGIBLE.WPB AMEND. TO | | | 2010 FBC SEC. 107.2.1. | | | 6) SHOW THE CORRESPONDING EHD FOR THE CSST PIPING. WPB | | | AMEND. TO 2010 FBC SEC. 107.2.1. | | | 7) SOME OF THE INFO ON THE TOP OF THE PIPNG PLAN IS CUT | | | OFF. | | | 8) DETAILS # 1 & #2 - WHAT IS THE 75,000 BTU LOAD AT | | | THE TOP OF THE PAGE FOR? THE PIPING PLAN SHOWS THE | | | DETAILS AS 150,000 BTU'S. | | | 9) WHAT DOES DETAIL # 1 & # 2 REPRESENT? WHAT TYPE OF | | | APPLIANCE IS THIS? | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | 2014-03-05 10:59:17 | RESTAMP | | 2014-02-25 14:13:08 | 2/25/2014 | | | THIS REVIEW WILL NOT CONTINUE: | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-01-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-01-18 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-01-10 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2014-01-16 16:55:10 | BUILDING PLAN REVIEW | | | PERMIT: 13100124 | | | ADD: 815 UPLAND RD | | | CONT: MASTER PLAN INC | | | TEL: (561) 683-9972 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: THURSDAY JAN. 16/ 2014 | | | ACTION: BUILDING PROVISO | | | | | | 2010 EXISTING BUILDING CODE | | | METHOD OF COMPLIANCE: DESIGNER OF RECORD HAS CHOSEN | | | PRESCRIPTIVE | | | PALM BEACH COUNTY PROPERTY APPRAISERS OFFICE BUILT IN | | | 1930 | | | | | | 2010 FL EXST BLDG CODE 301.2.1 EXISTING MATERIALS. | | | MATERIALS ALREADY IN USE IN A BUILDING IN COMPLIANCE | | | WITH REQUIREMENTS OR APPROVALS IN EFFECT AT THE TIME OF | | | THEIR ERECTION OR INSTALLATION SHALL BE PERMITTED TO | | | REMAIN IN USE UNLESS DETERMINED BY THE CODE OFFICIAL TO | | | BE DANGEROUS TO LIFE, HEALTH OR SAFETY. WHERE SUCH | | | CONDITIONS ARE DETERMINED TO BE DANGEROUS TO LIFE, | | | HEALTH OR SAFETY, THEY SHALL BE MITIGATED OR MADE SAFE. | | | | | | 1929 BUILDING CODE CITY OF WEST PALM BEACH | | | FIRE SEPERATION SEC 1300 H - OCCUPANCY HOTEL, | | | APARTMENTS, ROOMING HOUSES & RESTARAUNTS (BETWEEN | | | OCCUPANCIES) | | | CHAP. XIII REQUIREMENTS FOR GROUP "H" OCCUPANCY ( SS) | | | NOTE: SPECIAL SEPERATION | | | TYPE V BUILD 2 STORY FRONTAGE ON ONE STREET 3600 SQ FT, | | | CODE COMPLIANT, | | | PARTIII DETAILED REGULATIONS CHAPTER 33 STAIRS AND | | | EXITS (PAGE 87) THE NUMBER OF STAIRWAYS AND OR EXITS | | | REQUIRED IN ANY BUILDING CLASSED IN GROUPS D,E,F,G AND | | | I SHALL BE DETERMINED AS FOLLOW: | | | NO REQUIREMENTS FOR TYPE H OCCUPANCY : HOTEL, | | | APARTMENTS, ROOMING HOUSES & RESTARAUNTS FOR STAIRS OR | | | EXITS IN REGARDS TO FIRE RATING. | | | SECTION 3303. MINIMUM WIDTH OF STAIRS IS 34 INCHES IN | | | GROUP- D,E,F,& G BUILDINGS. NO MIN FOR H OCCUPANCIES. | | | CHAPTER 44 FIRE RESISTANCE STANDARDS, PROTECTION OF | | | STRUCTURAL PARTS WOOD JOIST WITH FLOOR WITH DOUBLE | | | BOARD ON TOP OF JOIST AND GYPSUM OR PORTLAND CEMENT | | | PLASTER 3/4 HR | | | IN THE 2010 FBC-B THE PRESCRIPTIVE FIRE RESISTANCE | | | TABLE 720.1(3)13.1.1 THE SAME FLOOR CONFIGURATION WILL | | | PROVIDE 7/8 HR PROTECTION. | | | | | | 1) 2010 FL EXST BLDG CODE 301.2.2 NEW AND REPLACEMENT | | | MATERIALS. | | | EXCEPT AS OTHERWISE REQUIRED OR PERMITTED BY THIS CODE, | | | MATERIALS PERMITTED BY THE APPLICABLE CODE FOR NEW | | | CONSTRUCTION SHALL BE USED. LIKE MATERIALS SHALL BE | | | PERMITTED FOR REPAIRS AND ALTERATIONS, PROVIDED NO | | | HAZARD TO LIFE, HEALTH OR PROPERTY IS CREATED. | | | HAZARDOUS MATERIALS SHALL NOT BE USED WHERE THE CODE | | | FOR NEW CONSTRUCTION WOULD NOT PERMIT THEIR USE IN | | | BUILDINGS OF SIMILAR OCCUPANCY, PURPOSE AND LOCATION. | | | | | | 1A) THE WINDOW AND DOOR OPENINGS (THE INFILL) THAT ARE | | | BEING CLOSED IN WILL NEED TO COMPLY WITH THE 2010 FL | | | BLDG CODE REQUIRING A 1 HR FIRE RATING PER SECTION | | | 709.1 GENERAL. | | | THE FOLLOWING WALL ASSEMBLIES SHALL COMPLY WITH THIS | | | SECTION. 1. WALLS SEPARATING DWELLING UNITS IN THE SAME | | | BUILDING AS REQUIRED BY SECTION 438.2. 439.2 SEPARATION | | | WALLS. | | | WALLS SEPARATING DWELLING UNITS IN THE SAME BUILDING, | | | WALLS SEPARATING SLEEPING UNITS IN THE SAME BUILDING | | | AND WALLS SEPARATING DWELLING OR SLEEPING UNITS FROM | | | OTHER OCCUPANCIES CONTIGUOUS TO THEM IN THE SAME | | | BUILDING SHALL BE CONSTRUCTED AS FIRE PARTITIONS IN | | | ACCORDANCE WITH SECTION 709. 709.3 FIRE-RESISTANCE | | | RATING. | | | FIRE PARTITIONS SHALL HAVE A FIRE-RESISTANCE RATING OF | | | NOT LESS THAN 1 HOUR. PROVIDE UL | | | | | | 1B) ANY NEW PENETRATION OF THE TENANT SEPERATION WALL | | | OR FLOOR/ CEILING ASSEMBLY WILL ALSO REQUIRE COMPLIANCE | | | WITH 713.3.1.2 THROUGH -PENETRATION FIRE STOP SYSTEMS. | | | | | | 1C) ALL NEW TENANT ENTRY DOORS ARE TO BE 1 HOUR FIRE | | | RATED AS PER 2010 FBC-B TABLE 715.4 AND AS REQUESTED BY | | | THE DESIGNER OF RECORD. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | THIS REVIEW WILL CONTINUE 01/17/2014 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-10-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-10-28 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-10-28 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2013-10-28 11:21:58 | BUILDING PLAN REVIEW | | | PERMIT: 13100124 | | | ADD: 815 UPLAND RD | | | CONT: MASTER PLAN INC | | | TEL: (561) 683-9972 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. OCT 28/ 2013 | | | ACTION: DENIED | | | | | | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) 2010 FL EXISSTING BUILDING CODE, THE DESIGNER OF | | | RECORD HAS NOT COMPLIED WITH 2010 FL EXT DLDG CODE | | | 101.5 COMPLIANCE METHODS. | | | THE REPAIR, ALTERATION, CHANGE OF OCCUPANCY, ADDITION | | | OR RELOCATION OF ALL EXISTING BUILDINGS SHALL COMPLY | | | WITH ONE OF THE METHODS LISTED IN SECTIONS 101.5.1 | | | THROUGH 101.5.3 AS SELECTED BY THE APPLICANT. | | | APPLICATION OF A METHOD SHALL BE THE SOLE BASIS FOR | | | ASSESSING THE COMPLIANCE OF WORK PERFORMED UNDER A | | | SINGLE PERMIT UNLESS OTHERWISE APPROVED BY THE CODE | | | OFFICIAL. SECTIONS 101.5.1 THROUGH 101.5.3 SHALL NOT BE | | | APPLIED IN COMBINATION WITH EACH OTHER. | | | | | | 3) 107.3.5.1.1. MINIMUM PLAN REVIEW CRITERIA FOR | | | COMMERCIAL BUILDINGS: | | | OCCUPANCY TYPE ; R2 TRANSIENT OR NON-TRANSIENT | | | BUILDING TYPE; | | | FIRE SPRINKLERS: | | | FIRE SEPERATION: TENANT WALLS & FLOOR CEILING | | | ASSEMBLIES | | | FIRE RATED DOORS; | | | EXTERIOR STAIRS & REQUIREMENTS FOR FIRE RATED WINDOWS | | | AND OR DOORS WITH-IN 10'-0" OF THE DOOR 2010 FBC-B | | | 1026.6 | | | EGRESS WINDOWS | | | | | | 3) THE DESIGNER OF RECORD DID NOT INCLUDE A EXISTING | | | FLOOR PLAN, WITHOUT A EXISTING FLOOR PLANS AND | | | KNOWLEDGE OF COMPLIANCE METHOD A BUILDING PLAN REVIEW | | | IS JUST GUESS WORK!!!!! | | | THE INFORMATION ABOVE WILL HELP DEFINE WHAT WE ARE | | | ACTUALLY LOOKING FOR FOR MINIMUM PLAN REVIEW, WHAT IS | | | ACTUALLY THERE FOR FIRE RESISTANCE RATINGS AND WHAT WE | | | CAN ASK FOR UNDER THE EXISTING BUILDING CODE. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2014-03-03 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-03-03 |
Time |
19:23 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-03-03 |
Time |
18:26 |
Sent To |
FIRE |
|
| Notes |
| 2014-03-03 19:23:25 | PER NFPA 72, SECTION 4.4, THE DEDICATED FIRE ALARM | | | CIRCUIT BREAKER SHALL BE MARKED IN RED AND IDENTIFIED | | | AS ?FIRE ALARM CIRCUIT? AND BE MECHANICALLY PROTECTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2014-02-10 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-02-10 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-02-10 |
Time |
14:22 |
Sent To |
FIRE |
|
| Notes |
| 2014-02-10 15:12:14 | FOR DESERT LETS ADD THE FOLLOWING TO THE PLANS: | | | 1. THE DRAIN PUMP CIRCUIT AND CORRESPONDING LOAD SHALL | | | BE INCLUDED IN TO PANEL H. | | | THE WATER HEATER OVERFLOW AS WELL AS THE WASHING | | | MACHINE DRAIN BELOW THE SEWER TAP AND THEREFORE NEEDS | | | TO BE PUMPED UP FOR PROPER DRAINAGE. | | | 2. FACP DEDICATED CIRCUIT AND THE ASSOCIATED | | | REQUIREMENTS ARE NOT ADDRESSED ON THE REVISED PLANS. | | | FOR ANY QUESTIONS OR COMMENTS ON THIS REVIEW, PLEASE | | | CONTACT: | | | MIKE ALBARRAN, ELECTRICAL PLANS EXAMINER, PX3353 | | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | | PH: (561) 805-6718, EMAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-01-29 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-01-29 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-01-29 |
Time |
15:06 |
Sent To |
I |
|
| Notes |
| 2014-01-29 17:46:42 | THE FOLLOWING ITEMS SHALL BE ADDRESSED AND CORRECTED | | | ACCORDINGLY: | | | 1. NOW THAT THE METHOD OF HEATING THE WATER HAS BEEN | | | CLARIFIED, THE PRESSURIZATION AND DRAIN PUMP LOADS AND | | | CIRCUITS SHALL BE INCLUDED IN PANEL H. | | | 2. HAVING THE COMMUNAL LAUNDRY FACILITIES IN THE | | | BASEMENT BRING UP ADDITIONAL REQUIREMENTS FOR PROPER | | | LIGHTING OF BOTH THE LAUNDRY ROOM AND THE STAIRS TO THE | | | BASEMENT. THAT CIRCUIT HAS TO BE INCLUDED IN TO PANEL H | | | AS WELL. | | | 3. THE FBC-ENERGY CONSERVATION CODE HAS SPECIFIC | | | LIGHTING REQUIREMENTS, NOT OF WHICH ALL HAVE BEEN | | | ADDRESSED. INCLUDE A LIGHTING DIAGRAM/SCHEMATIC | | | INDICATING HOW THE HOUSE LIGHTS WILL BE CONTROLLED. | | | INCLUDE THE ENTRY TO THE BASEMENT. IF THE BASEMENTS | | | STAIR LIGHTING IS NOT ON AUTOMATIC SENSING, A MANUAL | | | SWITCH SHALL BE PROVIDED PRIOR TO ENTERING THE STAIRS. | | | 4. PANEL H DOES NOT INCLUDE THE REQUIRED DEDICATED | | | CIRCUIT FOR THE FIRE ALARM CONTROL PANEL, (FCP). | | | 5. BOTH THE FBC AND THE NFPA REQUIRE THAT THE FIRE | | | ALARM CONTROL PANEL (FCP) BE PROTECTED WITH A SMOKE | | | DETECTOR. | | | 6. ADDITIONAL FIRE ALARM RELATED COMMENTS MATCH THOSE | | | ALREADY ADDRESSED BY THE FIRE REVIEW. | | | | | | FOR ANY QUESTIONS OR COMMENTS ON THIS REVIEW, PLEASE | | | CONTACT: | | | MIKE ALBARRAN, ELECTRICAL PLANS EXAMINER, PX3353 | | | CITY OF WEST PALM BEACH BLDG. DEPARTMENT | | | (561) 805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-11-12 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2013-11-12 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2013-11-12 |
Time |
10:17 |
Sent To |
I |
|
| Notes |
| 2013-11-12 11:34:23 | THE INTENT OF THE FOLLOWING LLIST IS NOT TO CREATE A | | | "PUNCH :IST" FOR THE DESIGNER, NEVER THE LESS, THE | | | BELOW MENTIONED ITEMS AMONG OTHERS SHALL BE ADDRESSED: | | | 1. FBC-R 303.8 REQUIRES THAT HEATING BE PROVIDED, NON | | | OF WHICH IS REFLECTED ON EITHER THE ELECTRICAL PANEL | | | SCHEDULE, ELECTRICAL LOAD CALCS, OR ON THE AIR | | | CONDITIONING PAGE. | | | 2. THE PLANS DO NOT INDICATE IF THE WATER WILL BE | | | HEATED WITH GAS OR ELECTRIC, THEREFORE THE ELECTRICAL | | | LOAD CALC MAY NOT BE CORRECT. | | | 3. THE LEVEL OF ALTERATION DICTATES THE REQUIREMENT FOR | | | HAVING TO PROVIDE LAUNDRY FACILITIES, BUT THE NEC DOES | | | REQUIRE A LAUNDRY CKT BE INCLUDES IN THE LOAD CALCS. | | | 4. NEC 2008 SECTION 406.11 REQUIRE TAMPER-RESISTANT | | | DEVICES | | | 5. NEC 2008 SECTION 210.12 REQUIRES ARC-FAULT | | | PROTECTION | | | 6. THE SUBMITTED DRAWINGS SHOW THE AHU INSIDE AN | | | ATTIC/CEILING, THIS WILL REQUIRE COMPLIANCE W/NEC | | | 110.33(B) | | | 7. FBC-R SECTIONS 314 & 315 HAVE SPECIFIC SMOKE AND | | | CARBON MONOXIDE DETECTION REQUIREMENTS WHICH SHALL BE | | | ADHERED TO. | | | | | | SENT TO SH DESK | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2014-03-04 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-03-04 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-03-04 |
Time |
13:07 |
Sent To |
B |
|
| Notes |
| 2014-03-04 13:20:36 | 815 UPLAND ROAD | | | PERMIT #13100124 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | *****PROVISO - SUBMIT REVISION***** | | | | | | SHEET LS-1: THE PLANS SHOW WINDOW CALLOUT #1 AS A | | | RESCUE/ESCAPE WINDOW; HOWEVER, NONE OF THE WINDOWS ON | | | THE FLOOR PLAN ARE DESIGNATED AS A TYPE #1 ESCAPE | | | WINDOW. | | | | | | SHEET E-2: PROVIDE A COMBINATION SMOKE ALARM/CO | | | DETECTOR IN THE BASEMENT LAUNDRY ROOM. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | FIRE INVESTIGATOR & INSPECTOR | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | 2014-02-10 15:12:57 | IN BIN C3 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2014-01-22 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-01-22 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-01-21 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2014-01-22 11:30:59 | 815 UPLAND ROAD | | | PERMIT #13100124 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | GENERAL: PROVIDE AN EXTERIOR KEY SAFE TO ALLOW | | | EMERGENCY RESPONDERS NON-FORCIBLE ENTRY INTO THE | | | BUILDING DURING NON-BUSINESS HOURS. A KEY SAFE CAN BE | | | ORDERED FROM WWW.KNOXBOX.COM. | | | | | | SHEET A-4, STAIR DETAIL: COMBINATION STAIR | | | GUARD/HANDRAIL IS ONLY 34-INCHES ABOVE THE STAIR TREAD. | | | GUARDS, AT LEAST 42-INCHES TALL (MEASURED FROM THE | | | LEADING EDGE OF THE STAIR TREAD), SHALL BE PROVIDED AT | | | THE OPEN SIDES OF MEANS OF EGRESS (STAIRS, MEZZANINE, | | | ETC.) THAT EXCEED 30-INCHES ABOVE THE FLOOR. | | | | | | SHEET LS-1: PLANS ONLY SHOW ONE MEANS OF EGRESS FROM | | | THE DWELLING UNITS (INTERNAL EXIT STAIR); HOWEVER, TWO | | | MEANS OF EGRESS ARE REQUIRED PER NFPA 101 SECTION | | | 31.2.4.1. ESCAPE/RESUCE WINDOWS CAN BE USED AS A SECOND | | | MEANS OF ESCAPE IS SO DESIRED AND MUST BE SHOWN ON THE | | | PLANS AND MEET THE FOLLOWING CRITERIA: | | | (1) SUCH WINDOWS SHALL BE OPERABLE FROM THE INSIDE | | | WITHOUT THE USE OF TOOLS AND SHALL PROVIDE A CLEAR | | | OPENING OF NOT LESS THAN 20-INCHES IN WIDTH, 24-INCHES | | | IN HEIGHT, AND 5.7 SQ.FT. IN AREA. | | | (2) THE BOTTOM OF THE OPENING SHALL BE NOT MORE THAN | | | 44-INCHES ABOVE THE FLOOR. | | | (3) THE CLEAR OPENING SHALL ALLOW A RECTANGULAR SOLID, | | | WITH A WIDTH AND HEIGHT THAT PROVIDES NOT LESS THAN THE | | | REQUIRED 5.7 SQ.FT. OPENING AND A DEPTH OF NOT LESS | | | THAN 20-INCHES TO PASS FULLY THROUGH THE OPENING. | | | (4) WINDOWS MUST NOT BE LOCATED MORE THAN 20 FEET FROM | | | THE GROUND LEVEL. | | | | | | SHEET LS-1: THE EXISTING INTERNAL CORRIDORS RESULT IN A | | | DEAD-END CORRIDOR EXCEEDING 50 FEET AND A COMMON PATH | | | OF TRAVEL EXCEEDING 35 FEET WHICH IS PROHIBITED IN | | | EXISTING APARTMENT BUILDINGS PER NFPA 101 SECTION | | | 31.2.5.3.1 AND SECTION 31.2.5.4. REALIZING THE EXISTING | | | FIRE CODE VIOLATIONS CANNOT BE READILY REMEDIED, I | | | PROPOSE INSTALLING COMBINATION SMOKE/CARBON MONOXIDE | | | DETECTORS (TIED INTO THE EXISTING FIRE ALARM SYSTEM) | | | THROUGHOUT THE TWO CORRIDORS AND BASEMENT LAUNDRY AREA. | | | THESE ADDITIONAL DETECTION DEVICES WILL PROVIDE | | | OCCUPANTS WITH EARLY WARNING SHOULD A FIRE OCCUR. | | | | | | FIRE ALARM - ADDITIONAL SIGNAGE NEEDED: A PERMANENT, | | | WEATHERPROOF SIGN SHALL BE PROVIDED AT EACH MANUAL FIRE | | | ALARM PULL BOX READING "LOCAL ALARM ONLY - IN CASE OF | | | FIRE CALL 911" .THE LETTERING AND NUMBERS ON APPROVED | | | SIGNS SHALL HAVE A MINIMUM HEIGHT OF 1/2-INCH, WITH A | | | MINIMUM 1/8-INCH STROKE WIDTH, AND SHALL BE WHITE IN | | | COLOR ON RED BACKGROUND LOCATED NO HIGHER THAN 4-INCHES | | | DIRECTLY ABOVE THE MANUAL FIRE ALARM BOX. | | | | | | FIRE ALARM: A COMBINATION VISUAL AND AUDIBLE | | | NOTIFICATION DEVICE IS NEEDED ON THE OUTSIDE WALL | | | (ADDRESS SIDE). | | | | | | FIRE ALARM: THE EXISTING FIRE ALARM CONTROL PANEL | | | APPEARS TO BE NON-FUNCTIONAL AS WAS OBSERVED ON A FIELD | | | INSPECTION (01/21/14). PROVIDE DRAWING NOTE INDICATING, | | | "FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED BY EMAIL ([email protected]) OR IN WRITING | | | (FAX: 561-804-4774) AND APPROVED BY THE OFFICE OF THE | | | FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY." | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | FIRE INVESTIGATOR & INSPECTOR | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2013-11-12 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-11-12 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-11-12 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2013-11-12 15:01:34 | 815 UPLAND ROAD | | | PERMIT #13100124 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | THE PLANS SHOW NEW WORK; HOWEVER, NO EXISTING FLOOR | | | PLANS HAVE BEEN PROVIDED. THE PLANS APPEAR TO BE | | | ENCLOSING APARTMENT UNIT DOORS (EGRESS DOORS) THAT WERE | | | LEADING TO A COMMON CORRIDOR. | | | | | | PROVIDE A LIFE SAFETY PLAN SHOWING ALL FIRE RATED | | | WALLS, ESCAPE WINDOWS, EXIT SIGNS, EMERGENCY LIGHTING, | | | TRAVEL DISTANCES, COMMON PATH OF TRAVEL ETC. | | | | | | A COMPLETE AND THOROUGH PLAN REVIEW CANNOT BE PERFORMED | | | AT THIS TIME DUE TO LACK OF PLAN INFORMATION. | | | | | | WESLEY JOLIN | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2014-10-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-10-20 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-10-20 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2014-10-20 14:29:01 | 1) SUBMIT COPIES OF THE APPLICABLE GAS SIZING TABLES | | | FOR THE PIPE MATERIAL FROM THE 2010 FGC. | | | 2) SHOW THE TOTAL DISTANCE OF PIPING FROM THE POINT OF | | | DELIVERY TO THE MOST REMOTE OUTLET PER THE 2010 FGC | | | SEC.402.4.1. | | | 3) SHOW THE TOTAL BTU LOAD ON THE SYSTEM. WPB AMEND. TO | | | 2010 FGC SEC. 107.2.1. | | | 4)IDENTIFY ALL THE APPLIANCES ON THE GAS DRAWING. WPB | | | AMEND. TO 2010 FGC SEC. 107.2.1. | | | 5) INDICATE THE OPERATING PRESSURE (PSI) OF THE SYSTEM. | | | WPB AMEND. TO 2010 FGC SEC. 107.2.1. | | | 6) SOME OF THE BTU LOADS ARE HARD TO READ. | | | 7) SHOW THE CORRESPONDING EHD FOR THE DIFFERENT SIZE OF | | | THE CSST. | | | 8) PART OF THE INFO ON THE TOP OF THE GAS PIPING | | | DRAWING IS CUT OFF. | | | 9) DETAILS # 1& #2 - WHAT ARE THE 3/4" CAPPED OFF LINES | | | FOR ON THE GAS PIPING DRAWING. | | | 10) WHAT IS THE 75,000 BTU LOAD SHOWN AT THE TOP OF THE | | | PAGE FOR DETAILS #1 & # 2 ? THE PIPING PLAN SHOWS THE | | | APPLIANCE AS 150,000 BTU'S. | | | 11) WHAT TYPE OF APPLIANCE IS DETAIL #1 & DETAIL #2. | | | THIS DRAWING IS CONFUSION. | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2014-01-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-01-18 |
Time |
14: |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-01-18 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2014-01-18 14:28:53 | GAS PROVISO: | | | THE WATER HEATER IS ELECTRIC AND NOT GAS PUTTING ON A | | | GREATER DEMAND. IN REVIEWING THE SIZING THE GAS DRYER | | | AT 22,000 BTU THIS IS LOW, THE AVERAGE DOMESTIC DRYER | | | (TYPE1) IS | | | 35,000 BTU/H, EVEN AT THAT RATE THE SIZING IS ADEQUITE. | | | 2010 FBC-G TABLE 402.2. | | | | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2014-01-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-01-18 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-01-18 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2014-01-18 14:00:48 | NO GAS REVIEW ON 1ST ROUND OF COMMENTS. JW |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
2013-10-25 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2013-10-25 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2013-10-25 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-03-05 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-03-05 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-02-06 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2014-02-07 16:35:36 | 2-6/14 RESUBMITTAL SENT TO C3 SHELF FOR REVIEW. JG. | | | | | | 2/12/14 ANOTHER RESUBMITTAL SUBMITTED IN THE MIDDLE OF | | | REVIEW. SENT TO C3 SHELF FOR REVIEW. JG. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-01-31 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-01-31 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2013-12-23 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2014-01-29 17:47:30 | SENT TO SH DESK | | 2013-12-26 08:42:52 | C26 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-11-12 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-11-12 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-10-03 |
Time |
09:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
N |
Date |
2014-03-05 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-03-05 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2014-01-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-01-18 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-01-18 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2013-10-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-10-28 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-10-28 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2013-10-28 11:22:46 | NOT ENOUGH INFORMATION FOR REVIEW. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-01-29 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-01-29 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-01-29 |
Time |
06:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2013-10-28 |
|
|
Cont ID |
|
| Sent By |
mricard |
Date |
2013-10-28 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
mricard |
Date |
2013-10-28 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2013-10-28 14:38:10 | FMC 301.2 PROVIDE ENERGY AND LOAD CALC FOR THE | | | EQUIPMENT TO BE INSTALLED. | | | FMC 304.1 PROVIDE MANUFACTURES PRODUCT INFO. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2014-03-05 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-03-05 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-03-05 |
Time |
09:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2014-01-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-01-18 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-01-18 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2014-01-18 12:37:54 | PLUMBING PLAN REVIEW | | | PERMIT: 13100124 | | | ADD: 815 UPLAND RD | | | CONT: MASTER PLAN INC | | | TEL: (561) 683-9972 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: SATURDAY JAN. 17/ 2014 | | | ACTION: DENIED | | | | | | 2010 EXISTING BUILDING CODE | | | METHOD OF COMPLIANCE: DESIGNER OF RECORD HAS CHOSEN | | | PRESCRIPTIVE | | | PALM BEACH COUNTY PROPERTY APPRAISERS OFFICE BUILT IN | | | 1930 | | | | | | 2010 FL EXST BLDG CODE 301.2.1 EXISTING MATERIALS. | | | MATERIALS ALREADY IN USE IN A BUILDING IN COMPLIANCE | | | WITH REQUIREMENTS OR APPROVALS IN EFFECT AT THE TIME OF | | | THEIR ERECTION OR INSTALLATION SHALL BE PERMITTED TO | | | REMAIN IN USE UNLESS DETERMINED BY THE CODE OFFICIAL TO | | | BE DANGEROUS TO LIFE, HEALTH OR SAFETY. WHERE SUCH | | | CONDITIONS ARE DETERMINED TO BE DANGEROUS TO LIFE, | | | HEALTH OR SAFETY, THEY SHALL BE MITIGATED OR MADE SAFE. | | | THE DEMOLITION PLANS SHOW THE LOCATION OF THE PLUMBING | | | FIXTURES, WHEN THEY ARE MOVED IT NO LONGER IS EXISTING | | | BUT CONSIDERED NEW WORK AND NEEDS TO COMPLY WITH THE | | | 2010 FBC-PLUMBING. | | | | | | 2010 FL EXST BLDG CODE 301.2.2 NEW AND REPLACEMENT | | | MATERIALS. | | | EXCEPT AS OTHERWISE REQUIRED OR PERMITTED BY THIS CODE, | | | MATERIALS PERMITTED BY THE APPLICABLE CODE FOR NEW | | | CONSTRUCTION SHALL BE USED. LIKE MATERIALS SHALL BE | | | PERMITTED FOR REPAIRS AND ALTERATIONS, PROVIDED NO | | | HAZARD TO LIFE, HEALTH OR PROPERTY IS CREATED. | | | HAZARDOUS MATERIALS SHALL NOT BE USED WHERE THE CODE | | | FOR NEW CONSTRUCTION WOULD NOT PERMIT THEIR USE IN | | | BUILDINGS OF SIMILAR OCCUPANCY, PURPOSE AND LOCATION. | | | | | | 1) 2ND REQUEST, PLEASE PROVIDE THE LOCATION OF THE | | | WATER HEATER THE ELECTRICAL PLANS INDICATE THE USE OF | | | INGIT OR WATER HEATER, LOCATION, SIZE, GAS OR ELECTRIC? | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010: | | | 107.3.5.1.3 PLUMBING , | | | (1) MINIMUM PLUMBING FACILITIES | | | (2) FIXTURE REQUIREMENTS | | | (5) WATER HEATERS | | | | | | 2) SHEET P-5 SHOWS THEAUTOMATIC CLOTHES WASHER WASTE | | | BEING PUMPED INTO THE BUILDING DRAIN BY USE OF A SUMP | | | PUMP. THERE ARE TWO ISSUES: | | | 2A) PLEASE PROVIDE THE MANUFACTURERS SPECIFICATION FOR | | | THIS SUMP PUMP FOR SIZE AND FLOW RATE CAPACITY AS WELL | | | AS THE CLOTHES WASHER PUMP DISCHARGE FLOW RATE TO | | | VERIFY THE SIZING OF THE SUMP PUMP WILL HAVE ENOUGH | | | CAPACITY TO ACCEPT THE DISCHARGE. P 712.3.1 SUMP PUMP | | | CAPACITY AND HEAD SHALL BE APPROPRIATE TO ANTIIPATE USE | | | REQUIREMENTS. | | | | | | 2B) SHEET P-5 NOTE ON THIS SHEET " SUMP PUMP TO CONNECT | | | TO THE EXISTING SANITARY LINE, CONTRACTOR TO VERIFY THE | | | SIZE & LOCATION AT SITE. THERE ARE STRICT REQUIREMENTS | | | FOR THE TIEING INTO THE BUILDING SEWER OR BUILDING | | | DRAIN. 2010 FBC-P 712.3.5 EJECTOR CONNECTION TO THE | | | DRAINAGE SYSTEM. | | | PUMPS CONNECTED TO THE DRAINAGE SYSTEM SHALL CONNECT TO | | | THE BUILDING SEWER OR SHALL CONNECT TO A WYE FITTING IN | | | THE BUILDING DRAIN A MINIMUM OF 10 FEET (3048 MM) FROM | | | THE BASE OF ANY SOIL STACK, WASTE STACK OR FIXTURE | | | DRAIN. WHERE THE DISCHARGE LINE CONNECTS INTO | | | HORIZONTAL DRAINAGE PIPING, THE CONNECTOR SHALL BE MADE | | | THROUGH A WYE FITTING INTO THE TOP OF THE DRAINAGE | | | PIPING. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2013-10-29 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-10-29 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-10-29 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2013-10-29 12:03:30 | FBC 2010 PLUMBING REVIEW #1 | | | DENIED: | | | | | | 1. SHEET P-1 & P-2: THE 2ND FLOOR SOIL STACK IS RUNNING | | | THROUGH THE FIRST FLOOR WET VENT. PLEASE SHOW THE SOIL | | | STACK DOWNSTREAM OF THE WET VENT. | | | 909.1 HORIZONTAL WET VENT PERMITTED. | | | ANY COMBINATION OF FIXTURES WITHIN TWO BATHROOM GROUPS | | | LOCATED ON THE SAME FLOOR LEVEL IS PERMITTED TO BE | | | VENTED BY A HORIZONTAL WET VENT. THE WET VENT SHALL BE | | | CONSIDERED THE VENT FOR THE FIXTURES AND SHALL EXTEND | | | FROM THE CONNECTION OF THE DRY VENT ALONG THE DIRECTION | | | OF THE FLOW IN THE DRAIN PIPE TO THE MOST DOWNSTREAM | | | FIXTURE DRAIN CONNECTION TO THE HORIZONTAL BRANCH | | | DRAIN. EACH WET-VENTED FIXTURE DRAIN SHALL CONNECT | | | INDEPENDENTLY TO THE HORIZONTAL WET VENT. ONLY THE | | | FIXTURES WITHIN THE BATHROOM GROUPS SHALL CONNECT TO | | | THE WET-VENTED HORIZONTAL BRANCH DRAIN. ANY ADDITIONAL | | | FIXTURES SHALL DISCHARGE DOWNSTREAM OF THE HORIZONTAL | | | WET VENT. | | | | | | 2. A DRAWING OF THE HOT AND COLD WATER WILL BE REQUIRED | | | WITH THE LOCATION OF THE WATER HEATER/S. | | | 107.3.5.1.3 PLUMBING | | | (1)MINIMUM PLUMBING FACILITIES | | | (2.) FIXTURE REQUIREMENTS | | | (3.) WATER SUPPLY PIPING | | | (5.) WATER HEATERS | | | ... | | | | | | 3. PLEASE INDICATE THE LOCATION OF THE AUTOMATIC | | | CLOTHES WASHER CONNECTION/S. | | | TABLE 403.1 | | | MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES (R-2) | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-10-25 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2013-10-25 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2013-10-25 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2013-10-09 13:30:36 | 10/9/13 |
|
|