Plan Review Details - Permit 13090952
| Plan Review Stops For Permit 13090952 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2013-10-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-10-23 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-10-23 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2013-10-23 10:07:04 | | | | BUILDING PLAN REVIEW | | | MASTER PERMIT: 12040784 | | | REVISION # 13090952 PHASED WORK ELECTRICAL ROOM # 6 | | | ADD: 6651 N JOG RD | | | CONT: KBR | | | TEL: (561 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. OCT. 23/ 2013 | | | ACTION: BUILDING PROVISO: | | | MISSING PRODUCT APPROVALS FOR NEW BUILDING A REVISION | | | IS REQUIRED. | | | | | | 1) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 2) 010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING | | | | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B), WALL LOUVERS, | | | (C) ROOFING PRODUCTS AND ASSEMBLIES | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-11-12 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2013-11-12 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2013-11-12 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2013-11-12 13:30:07 | THE ELECTRICAL SCOPE OF THIS PERMIT IS LIMITED ONLY TO | | | THE INSTALLATION OF THE ITEMS DESCRIBED HEREIN. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2013-10-09 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2013-10-09 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2013-10-09 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2013-10-09 11:30:20 | PERMIT #13090952 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | SHEET 400-A1.1: PANIC HARDWARE MAY BE NEEDED ON EXIT | | | DOORS. PER NFPA 70 ARTICLE 110.26(C)(3): WHERE | | | EQUIPMENT RATED 1200A OR MORE THAT CONTAINS OVERCURRENT | | | DEVICES, SWITCHING DEVICES, OR CONTROL DEVICES IS | | | INSTALLED AND THERE ARE PERSONNEL DOORS INTENDED FOR | | | ENTRANCE TO AND EGRESS FROM THE WORKING SPACE LESS THAN | | | 25 FEET FROM THE NEAREST EDGE OF THE WORKING SPACE, THE | | | DOORS SHALL OPEN IN THE DIRECTION OF EGRESS AND BE | | | EQUIPPED WITH PANIC BARS, PRESSURE PLATES, OR OTHER | | | DEVICES THAT ARE NORMALLY LATCHED BUT OPEN UNDER SIMPLE | | | PRESSURE. | | | | | | SUE ELLEN CALDERON | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4751 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-11-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-11-12 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-10-02 |
Time |
11:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2013-10-04 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2013-10-04 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2013-10-04 |
Time |
11:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2013-12-18 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2013-12-18 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2013-12-06 |
Time |
15:32 |
Sent To |
|
|
| Notes |
|
|
|