| 2013-09-28 10:33:08 | 2010 FBC |
| | |
| | DENIED BY BUILDING |
| | |
| | 1) SUBMIT TWO COPIES OF A SURVEY AND A SITE PLAN |
| | SHOWING THE LOCATION OF THE PROPOSED ADDITION. |
| | |
| | 2) THE PLANS SPECIFY THAT THE FOOTING, STEM WALL AND |
| | SLAB ARE EXISTING, HOWEVER, THE PROPERTY APPRAISER'S |
| | RECORDS DO NOT SHOW ANYTHING AT THE AREA OF THIS |
| | PROPOSED ADDITION. THE BUILDING DEPARTMENT RECORDS DO |
| | NOT INDICATE THAT THIS WORK WAS PERMITTED OR INSPECTED. |
| | A PERMIT FOR AN ADDITION (PERMIT # 07060979) WAS |
| | APPLIED FOR BY THE OWNER IN 2007. THIS PERMIT WAS NEVER |
| | ISSUED AND HAS EXPIRED. PROVIDE EVIDENCE THAT THE |
| | FOOTING, STEM WALL AND SLAB WERE PERMITTED AND PASSED |
| | INSPECTIONS. OTHERWISE THEY SHALL BE REMOVED OR |
| | EVALUATED BY A STRUCTURAL ENGINEER TO THE SATISFACTION |
| | OF THE CITY OF WEST PALM BEACH'S BUILDING DIVISION. |
| | CITY AMENDMENTS 109.4 & SECTION 114 |
| | |
| | 3) FBC R314.3.1 REQUIRES SMOKE ALARMS TO BE INSTALLED |
| | AS REQUIRED FOR NEW DWELLINGS WHEN ADDITIONS OR |
| | ALTERATIONS REQUIRING PERMITS OCCUR. SHOW COMPLIANCE. |
| | |
| | 4) THE PLANS SHOW A 2" X 6" RAFTERS IN A SINGLE ROOF / |
| | CEILING ASSEMBLY WITH R-30 INSULATION. R-30 BATT |
| | INSULATION IS 9.5" TO 10" THICK DEPENDING ON THE BRAND. |
| | A 2 X 6 WILL ONLY PROVIDE 5.5" OF SPACE BETWEEN THE |
| | CEILING AND ROOF SHEATHING, WHICH IS NOT ENOUGH SPACE |
| | FOR THE INSULATION AND AN AIR SPACE. PLEASE CORRECT. |
| | NOTE. THE ENERGY CALCULATION FORM REQUIRES A MINIMUM OF |
| | R-30 INSULATION. FBC ENERGY CONSERVATION 402.1 |
| | |
| | 5) FORM 402-2010 SPECIFIES CERTAIN PERFORMANCE CRITERIA |
| | THAT MUST BE MET. THE EXTERIOR WALL INSULATION FOR |
| | FRAME IS REQUIRED TO BE R-13 AND R-11 IS SPECIFIED ON |
| | THE FORM. R-11 IS INCORRECTLY SPECIFIED ON THE FORM FOR |
| | CONCRETE OR MASONRY " MASS" WALLS, THIS ADDITION DOES |
| | NOT HAVE EXTERIOR CONCRETE OR MASONRY WALLS. THERE ARE |
| | NO WALLS THAT ARE "ADJACENT" TO UNCONDITIONED SPACE. |
| | PLEASE CORRECT. FBC ENERGY CONSERVATION 402.1 |
| | |
| | 6) THE MAXIMUM DESIGN NEGATIVE PRESSURE FOR THE WINDOW |
| | IS SPECIFIED AS - 50 PSF ON THE PRODUCT APPROVAL |
| | (FL5418) AND THE REQUIRED NEGATIVE PRESSURE SPECIFIED |
| | ON THE PLAN IS -50.61 PSF. THE DESIGN PRESSURES FOR THE |
| | WINDOW ARE REQUIRED EXCEED THE REQUIRED PRESSURES. FBC |
| | R301.2.1 |
| | |
| | 7) THE PLANS SPECIFY A SIMONTON "STORM BREAKER" SERIES |
| | WINDOW AND THE PRODUCT APPROVAL EVALUATION AND |
| | INSTALLATION INSTRUCTIONS IS FOR THE "SAFEPOINT" |
| | SERIES. PLEASE CLARIFY. CITY AMENDMENTS 107.2.1 |
| | |
| | 8) THE PRODUCT APPROVAL FOR THE TAMKO MODIFIED ROOFING |
| | SYSTEM NOA NO. 12-0716.18 HAS BEEN REPLACED BY NOA NO. |
| | 12-1003.05. PLEASE SUBMIT THE CURRENT PRODUCT APPROVAL |
| | THAT HAS BEEN REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD. DCA RULE 9N-3 AND CITY AMENDMENTS |
| | 107.3.4.1 |
| | |
| | 9) SPECIFY THE APPROVED ASSEMBLY, THE FASTENING OPTION |
| | AND THE MINIMUM DESIGN PRESSURES THAT WILL BE USED TO |
| | INSTALL THE TAMKO ROOFING SYSTEM. PROVIDE TWO SETS OF |
| | SIGNED AND SEALED RAS 117 CALCULATIONS FOR ENHANCED |
| | FASTENING FOR THE PERIMETER AND CORNER ROOF AREAS, AS |
| | REQUIRED BY LIMITATION #7 ON THE LAST PAGE OF THE NOA. |
| | FBC R905.1 |
| | |
| | 10) THE VALUE FOR THE WORK SPECIFIED ON THE APPLICATION |
| | OF $1500.00 IS TOO LOW. FOR PERMITTING FEE PURPOSES THE |
| | VALUE IS TO BE THE TOTAL REPLACEMENT VALUE INCLUDING |
| | STRUCTURAL, ELECTRICAL, DESIGN FEES, OVERHEAD AND |
| | PROFIT AS WOULD BE CHARGED BY A CONTRACTOR. PLEASE |
| | PROVIDE AN ACCURATE CONSTRUCTION COST VALUE. CITY |
| | AMENDMENTS 109.3 |
| | |
| | 11) IN ORDER TO SPEED PLAN REVIEW TIME, PLEASE SUBMIT A |
| | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW |
| | COMMENTS WAS ADDRESSED. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |
| | [email protected] |