Plan Review Details - Permit 13090724
Plan Review Stops For Permit 13090724
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-10-15 Cont ID  
Sent By shill Date 2013-10-15 Time 13:06 Rev Time 0.00
Received By shill Date 2013-10-15 Time 13:06 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-09-25 Cont ID  
Sent By shill Date 2013-09-25 Time 19:44 Rev Time 0.00
Received By shill Date 2013-09-25 Time 19:44 Sent To  
Notes
2013-09-25 19:45:05****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. REVISE FLOOR PLAN TO PROVIDE THE FOLLOWING
 INFORMATION FOR BEDROOMS; FBC R310, FBC EB 604.1. THE
 CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%:
  
 REVISE PLAN TO STATE WHAT TYPE OF WINDOW IS THERE NOW
 IN THE BEDROOMS - AWNING, CASEMENT, SINGLE HUNG?
  
 REVISE PLAN TO STATE WHAT THE EXISTING CLEAR OPENING
 DIMENSIONS ARE. CLEAR OPENING IS THE OPENING WHICH
 EXISTS WHEN THE WINDOW IS FULLY OPEN.
  
 REVISE PLAN TO STATE WHAT THE PROPOSED CLEAR OPENING
 DIMENSIONS ARE. THIS CAN BE OBTAINED FROM THE
 MANUFACTURER.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-10-15 Cont ID  
Sent By shill Date 2013-10-15 Time 13:06 Rev Time 0.00
Received By shill Date 2013-10-02 Time 15:28 Sent To  
Notes
2013-10-02 15:28:36SENT TO S HILL DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-09-25 Cont ID  
Sent By shill Date 2013-09-25 Time 19:45 Rev Time 0.00
Received By shill Date 2013-09-23 Time 10:42 Sent To  
Notes
2013-09-24 10:42:58SENT TO MISCELLANEOUS SHELF #1 FOR REVIEW. JG.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved