| Plan Review Stops For Permit 13090656 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-01-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-01-06 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-01-06 |
Time |
13:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-09-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-09-27 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-09-27 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2013-09-27 12:01:59 | BUILDING PLAN REVIEW | | | PERMIT: 13090656 | | | ADD: 4310 BROADWAY | | | CONT: CHARLES CULPPEPER | | | TEL: (786)229-8862 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: SEPT 27/2013 | | | ACTION: DENIED | | | | | | 1) SHEET A1 & A2 NEITHER SHEET PROVIDE DETAILS IN | | | REGARDS TO THE STRUCTURAL REQUIREMENTS FOR THE NEW | | | LOCATION OF THE BACK EXIT DOOR. WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION, 2010 EDITION. SECTION 107.3.5.1.1.8 | | | STRUCTURAL REQUIREMENTS, IF CBC PROVIDE DETIALS FOR | | | COLUMNS & LINTEL, IF WOOD FRAME CONSTRUCTION THEN, | | | HEADER SIZE, STUDS & JACKS, AND STRAPING BEING PART OF | | | THE MWFRS. | | | | | | 2) PROVIDE PRODUCT APPROVAL FOR EXTERIOR DOOR. 2010 | | | FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 | | | COMPONENTS & CLADDING | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | | | | 3) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 4) INTERIOR CBS WALL IS BEING REMOVED, NO INFORMATION | | | HOW THE OPENING THAT IS BEING ENLARGED IS BEING | | | RE-INFORCED? 107.2.1.3. ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2014-01-16 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-01-16 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-01-16 |
Time |
14:25 |
Sent To |
I |
|
| Notes |
| 2014-01-16 14:28:14 | ACCORDING TO THE GENERAL CONTRACTOR, THERE WILL BE NO | | | ELECTRICAL WORK PERFORMED ON THE PROJECT. THEREFORE NO | | | ELECTRICAL WORK WAS REVIEWED OR AUTHORIZED. THE PLANS | | | ARE MARKED AS FOLLOWS: | | | NOTICE: | | | AS PER THE SCOPE OF THIS PERMIT, NO ELECTRICAL WORK | | | IS PERMITTED AND THEREFORE AUTHORIZED. | | | THE PERFORMANCE OF ANY ELECTRICAL WORK WITHOUT THE | | | BENEFIT | | | OF A PERMIT SHALL BE GROUNDS FOR A STOP WORK ORDER, | | | UNDER | | | FBC-B SECTION 115. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-10-24 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2013-10-24 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2013-10-24 |
Time |
16:49 |
Sent To |
I |
|
| Notes |
| 2013-10-24 16:49:57 | NEED ELECTRICAL DRAWINGS FOR THE PROPOSED WORK. NEED A | | | SITE PLAN AND ELEVATIONS AS WELL. | | | SENT TO SH DESK |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2013-12-27 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-12-27 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-12-27 |
Time |
11:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2013-09-28 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-09-28 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-09-28 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2013-09-28 10:07:20 | 4310 BROADWAY | | | PERMIT #13090656 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | WHAT IS THE OCCUPANT LOAD FOR THIS SPACE? PER NFPA 101 | | | SECTION 7.2.1.4.2, DOORS ARE REQUIRED TO SWING IN THE | | | DIRECTION OF EGRESS TRAVEL FOR AN OCCUPANT LOAD OF 50 | | | OR GREATER PERSONS. | | | | | | DOORS SHALL BE ARRANGED TO BE OPENED READILY FROM THE | | | EGRESS SIDE WHENEVER THE BUILDING IS OCCUPIED. LOCKS, | | | IF PROVIDED, SHALL NOT REQUIRE THE USE OF A KEY, TOOL, | | | OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM THE | | | EGRESS SIDE. | | | | | | PER NFPA 101 SECTION 7.2.1.5.9, THE LOCK/LATCH | | | RELEASING MECHANISM ON ALL DOORS SHALL OPEN THE DOOR | | | WITH NOT MORE THAN ONE RELEASING OPERATION. THE | | | RELEASING MECHANISM SHALL HAVE AN OBVIOUS METHOD OF | | | OPERATION THAT IS READILY OPERATED UNDER ALL LIGHTING | | | CONDITIONS. THE RELEASING DEVICE SHOULD BE CAPABLE OF | | | BEING OPERATED WITH ONE HAND AND SHOULD NOT REQUIRE | | | TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST | | | TO OPERATE. | | | | | | THE EXISTING FLOOR PLAN DOES NOT SHOW ANY REAR WINDOWS; | | | HOWEVER, THE NEW FLOOR PLANS INDICATE THREE NEW REAR | | | WINDOWS. | | | | | | WESLEY JOLIN | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-02-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-02-04 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-12-16 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2014-01-16 14:55:25 | RETURNED TO B8 | | | | | 2014-01-16 14:30:24 | SENT TO SH DESK | | 2013-12-17 14:21:06 | RESUBMITTAL SENT TO B8 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-10-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-10-24 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-09-20 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2013-10-17 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-10-17 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-10-17 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2013-10-17 13:29:20 | NO MECHANICAL WORK AT THIS TIME. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-02-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-02-03 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-02-03 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2014-02-03 11:53:19 | PLUMBING PROVISO: | | | | | | HOOK UP OF NEW 3 COMPARTMENT SINK WILL REQUIRE INDIRECT | | | WASTE | | | THROUGH EITHER A AIR GAP OR AN AIR BREAK TO EITHER A | | | FLOOR SINK OR | | | HUB DRAIN PER 2010 FBC-P 802.1.8. | | | | | | | | | | | | PLUMBING PROVISO: | | | | | | HOOK UP OF NEW 3 COMPARTMENT SINK WILL REQUIRE INDIRECT | | | WASTE | | | THROUGH EITHER A AIR GAP OR AN AIR BREAK TO EITHER A | | | FLOOR SINK OR | | | HUB DRAIN PER 2010 FBC-P 802.1.8. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-01-02 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2014-01-02 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2014-01-02 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2014-01-02 13:38:58 | FBC 2010 PLUMBING REVIEW #1 | | | DENIED: | | | | | | 1. IF NEW PLUMBING FIXTURES ARE BEING ADDED, A PLUMBING | | | DRAWING WILL BE RQUIRED. | | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1.3 PLUMBING | | | | | | 2. IF THE SINK/S SHOWN ARE USED FOR GREASE-LADEN WASTE, | | | THE WASTE SHALL BE ROUTED TO AN INTERCEPTOR. | | | 1003.3.1 GREASE INTERCEPTORS AND AUTOMATIC GREASE | | | REMOVAL DEVICES REQUIRED. | | | A GREASE INTERCEPTOR OR AUTOMATIC GREASE REMOVAL DEVICE | | | SHALL BE REQUIRED TO RECEIVE THE DRAINAGE FROM FIXTURES | | | AND EQUIPMENT WITH GREASE-LADEN WASTE LOCATED IN FOOD | | | PREPARATION AREAS, SUCH AS IN RESTAURANTS, HOTEL | | | KITCHENS, HOSPITALS, SCHOOL KITCHENS, BARS, FACTORY | | | CAFETERIAS AND CLUBS. FIXTURES AND EQUIPMENT SHALL | | | INCLUDE POT SINKS, PRERINSE SINKS; SOUP KETTLES OR | | | SIMILAR DEVICES;WOK STATIONS; FLOOR DRAINS OR SINKS | | | INTO WHICH KETTLES ARE DRAINED; AUTOMATIC HOOD WASH | | | UNITS AND DISHWASHERS WITHOUT PRERINSE SINKS.GREASE | | | INTERCEPTORS AND AUTOMATIC GREASE REMOVAL DEVICES SHALL | | | RECEIVE WASTE ONLY FROM FIXTURES AND EQUIPMENT THAT | | | ALLOW FATS, OILS OR GREASE TO BE DISCHARGED. | | | | | | | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2013-09-24 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2013-09-24 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2013-09-24 |
Time |
11:34 |
Sent To |
|
|
| Notes |
|
|