Plan Review Details - Permit 13090621
Plan Review Stops For Permit 13090621
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2014-03-17 Cont ID  
Sent By jwitmer Date 2014-03-17 Time 08:23 Rev Time 0.00
Received By jwitmer Date 2014-03-17 Time 08:23 Sent To  
Notes
2014-03-17 08:44:58ROOF APPROVED WITH GAF TIMBERLINE SHINGLES. NOA
 13-0419.04 JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2014-01-03 Cont ID  
Sent By jwitmer Date 2014-01-03 Time 13:41 Rev Time 0.00
Received By jwitmer Date 2013-12-20 Time 11:46 Sent To  
Notes
2014-01-03 13:48:20BUILDING PLAN REVIEW
 PERMIT:13090621
 ADD: 3516 S DIXIE HWY
 CONT: ALLEN GAST
 TEL: (561)833-3535
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: 01/03/2014
 ACTION: DENIED
  
 1) 2ND REQUEST. SHEET A-1.00 INDICATES THE USE OF FOAM
 SPRAY INSULATION IN THE ATTIC AREA, PLEASE PROVIDE
 PRODUCT TESTING FOR FLAME SPREAD AND PRODUCT
 INSTALATION AND PRODUCT LIMITATIONS PER 2010 FBC-B
 2603.3.ALSO REVIEW 2603.4 THERMAL BARRIER AND 2603.4.1
 & 2603.4.1.1.
 ICC NER-420 ICYNENE REPORT LIST UNDER THE HEADING (4.0)
 LIST 5 APPLICATION TYPES THE DESIGNER OF RECORD WILL
 NEED TO IDENTIFY WHICH SUB-SYSTEM IS TO BE INSTALLED
 FOR THIS PROJECT, DEPENDING OF SUB-SYSTEM SOME MAY
 REQUIRE A IGNITION BARRIER AND OR THEERMAL BARRIER.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-09-27 Cont ID  
Sent By jwitmer Date 2013-09-27 Time 07:52 Rev Time 0.00
Received By jwitmer Date 2013-09-27 Time 07:19 Sent To  
Notes
2013-09-27 07:51:58BUILDING PLAN REVIEW
 PERMIT:
 ADD:
 CONT:
 TEL: (561
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 REVIEW
 DATE:
 ACTION: DENIED
  
 1) PLEASE PROVIDE A SURVEY OF THE LOT. AMENDMENT TO THE
 FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010
 EDITION, SECTION 107.3.5.1.1 COMMERCIAL SITE
 REQUIREMENTS.
  
 2) UNITY OF TITLE. THE PROPOSED BUILDING STRUCTURE
 TRANSGRESSES LEGAL BOUNDARY LINES BETWEEN THE LOTS
 WHICH COMBINE TO FORM 'THE SITE'. A 'UNITY OF TITLE'
 SHALL BE
 RECORDED AT THE COUNTY COURTHOUSE. SUBMIT A COPY OF THE
 RECORDED 'UNITY OF OF TITLE' DOCUMENT SO THAT FBC TABLE
 601 BOUNDARY LINE REQUIREMENTS MAY BE DEEMED
 NOT APPLICABLE.
 SEE WEBSITE FOR APPLICATION:
 HTTP://WWW.WPB.ORG/ENGINEERING/ENG_FORMS.PHP
 "APPLICATION FOR UNITY OF TITLE"
  
 HTTP://WWW.WPB.ORG/ENGINEERING/UPLOADS/2010-10-12-14-45
 -38-UNITYOFTITLE3.PDF
  
 VINCENT J NOEL
 SURVEYOR/REAL ESTATE SUPERVISOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET
 WEST PALM BEACH, FL 33401
 PHONE: 494-1040 EXT: 1096
 FAX: 494-1116
 E-MAIL: [email protected]
  
 *********************************************
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
 3) SHEET A-1.00 INDICATES THE USE OF FOAM SPRAY
 INSULATION IN THE ATTIC AREA, PLEASE PROVIDE PRODUCT
 TESTING FOR FLAME SPREAD AND PRODUCT INSTALATION AND
 PRODUCT LIMITATIONS PER 2010 FBC-B 2603.3.ALSO REVIEW
 2603.4 THERMAL BARRIER AND 2603.4.1 & 2603.4.1.1.
  
 4) SHEET A-1.00 INDICATES THE USE OF DIMENSIONAL
 ASPHALT SHINGLES PLEASE PROVIDE COMPLIANCE WITH ;
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31(D) ROOFING PRODUCTS AND ASSEMBLIES
  
 5) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC.
  
 6) THE TYPE OFTERMITE TREATMENT IS NOT INDICATED ON
 PLANS IF OPTION FBC-B 1816.4 IS OPTED THE CHEMICALLY
 TREATED SOIL SHALL BE PROTECTED WITH A MINIMUM 6
 MILLIMETER VAPOR RETARDER TO PROTECT AGAINST RAINFALL
 DILUTION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2013-09-26 Cont ID  
Sent By wjolin Date 2013-09-26 Time 12:34 Rev Time 0.00
Received By wjolin Date 2013-09-26 Time 12:34 Sent To  
Notes
2013-09-26 12:34:12STRUCTURES WITH LIGHT FRAME FLOOR/ROOF TRUSS
 CONSTRUCTION SHALL BE IDENTIFIED WITH A SIGN AFFIXED TO
 THE BUILDING. THE SIGN SHALL FEATURE A MALTESE CROSS
 8-INCHES WIDE AND 8-INCHES TALL AND BE OF A BRIGHT RED
 REFLECTIVE COLOR AND BEAR THE LETTER "R" DESIGNATION
 PER FLORIDA STATUTE 633.027 AND FLORIDA ADMINISTRATIVE
 CODE 69A-60.0081.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-03-17 Cont ID  
Sent By jwitmer Date 2014-03-17 Time 08:26 Rev Time 0.00
Received By jwitmer Date 2014-03-03 Time 09:22 Sent To  
Notes
2014-03-04 09:24:16B22
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-01-03 Cont ID  
Sent By jwitmer Date 2014-01-03 Time 13:48 Rev Time 0.00
Received By jwitmer Date 2013-12-05 Time 17:27 Sent To  
Notes
2013-12-05 17:27:39B16

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-11-05 Cont ID  
Sent By dkittred Date 2013-10-01 Time 09:58 Rev Time 0.00
Received By shill Date 2013-09-23 Time 10:28 Sent To  
Notes
2013-10-01 09:58:37IN DENIED FILES UNDER 'A'. DK
2013-09-24 10:28:23SENT TO B6 SHELF FOR REVIEW. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2014-03-21 Cont ID  
Sent By jwitmer Date 2014-03-21 Time 15:17 Rev Time 0.00
Received By jwitmer Date 2014-03-21 Time 15:17 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2013-09-27 Cont ID  
Sent By jwitmer Date 2013-09-27 Time 07:52 Rev Time 0.00
Received By jwitmer Date 2013-09-27 Time 07:52 Sent To  
Notes
2013-09-27 07:52:38BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 2014-03-05 Cont ID  
Sent By dkittred Date 2014-03-05 Time 09:47 Rev Time 0.00
Received By dkittred Date 2014-03-05 Time 09:27 Sent To  
Notes
2014-03-05 09:48:083/4/14 SENT BACK TO B22. DK
  
2014-03-05 09:47:18UNITY OF TITLE FOR THE SUBJECT PROPERTY WAS RECORDED IN
 ORB 26450 PG 1543. DK

Review Stop Z ZONING
Rev No 2 Status F Date 2013-12-09 Cont ID  
Sent By dkittred Date 2013-12-09 Time 10:17 Rev Time 0.00
Received By dkittred Date 2013-12-09 Time 10:12 Sent To  
Notes
2013-12-09 10:17:3212/9/13
 EMAILED APPLICANT P&Z COMMENTS. - DK
  
2013-12-09 10:16:08PLANNING & ZONING COMMENTS: ***FAILED***
  
 12/9/13
 PREVIOUS COMMENTS WERE ONLY PARTIALLY ADDRESSED.
 RESUBMITTAL DID NOT INCLUDE LOCATION OF ADDITION WITH
 SETBACKS. THIS ITEM WILL NEED TO BE SUBMITTED FOR P&Z
 TO COMPLETE THEIR REVIEW.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561)-822-1443
 EMAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2013-10-01 Cont ID  
Sent By jroach Date 2013-10-01 Time 09:49 Rev Time 0.00
Received By dkittred Date 2013-09-30 Time 10:12 Sent To  
Notes
2013-10-01 08:54:44PLANNING & ZONING COMMENTS: ***FAILED***
  
 1. NO SITE PLAN OR SURVEY WAS SUBMITTED TO INDICATE
 SETBACKS OF THE PROPOSED ADDITION. PLEASE SUMIT THESE
 ITEMS FOR REVIEW.
  
 2. PROPOSED ROOF ADDTION CONNECTS BUILDINGS ON TWO
 SEPARATE PARCELS, WHICH IS NOT PERMITTED. EITHER SUBMIT
 FOR A UNITY OF TITLE OF THE TWO PARCELS THROUGH THE
 ENGINEERING DEPARTMENT (561-494-1040) TO CORRECT THIS
 ISSUE OR PROPOSE A ROOF ADDITION THAT DOES NOT CROSS
 PARCEL BOUNDARIES.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561)-822-1443
 EMAIL: [email protected]
  
2013-09-30 10:42:589/30/13