Plan Review Details - Permit 13090516
| Plan Review Stops For Permit 13090516 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2013-09-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-20 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-09-20 |
Time |
17:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-09-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-20 |
Time |
17:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-09-20 |
Time |
17:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-09-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-20 |
Time |
17:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-09-18 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2013-09-18 11:24:59 | ROUTED TO ZONING |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2013-10-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-10-16 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-10-16 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2013-10-16 13:49:22 | MAIN DRAIN WAS CHANGED TO 3" TO ALLOW FOR MAXIMUM FLOW | | | RATE OF THE PENTAIR VS 3050 PUMP THAT WAS SPECIFIED ON | | | PLANS. CHANGE WAS RED-LINED ON PLANS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2013-09-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-20 |
Time |
17:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-09-20 |
Time |
17:41 |
Sent To |
|
|
| Notes |
| 2013-09-20 17:49:37 | 2010 FBC | | | | | | DENIED BY PLUMBING | | | | | | 1) THE INTELLIFLO VS 3050 POOL PUMP SPECIFIED ON SHEET | | | 2 OF THE PLANS HAS A MAXIMUM FLOW RATE OF 145 GPM WITH | | | A 50' TDH. THE WATER VELOCITY IN THE 2-1/2 " SUCTION | | | PIPING EXCEEDS THE 8 FEET PER SECOND ALLOWED BY FBCR | | | 4101.6.3. PLEASE CORRECT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2013-10-16 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2013-10-16 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2013-10-16 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2013-10-16 14:57:06 | PASSED WITH THE FOLLOWING PROVISOS: | | | | | | 1.) POOL DECK SHALL BE SETBACK 2 FT. FROM THE PROPERTY | | | LINE. | | | | | | 2.) POOL BARRIER PERMIT IS REQUIRED. PERMIT SHALL BE | | | APPROVED, AND BARRIER SHALL BE INSTALLED PRIOR TO C.O. | | | | | | CONTACT LINDA LOUIE @ (5610 822-1442 IF YOU HAVE | | | QUESTIONS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-09-18 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2013-09-18 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2013-09-18 |
Time |
15:53 |
Sent To |
P |
|
| Notes |
| 2013-09-18 15:55:59 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING. RESPOND TO THE COMMENTS | | | IN WRITING AND/OR ON THE PLANS WHERE APPLICABLE: | | | | | | 1.) THE SWIMMING POOL SHALL BE ENCLOSED BY A FENCE OR | | | SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS | | | BY PERSONS OTHER THAN THE OWNERS. (ZLDR S. 94-304 (D) | | | (2) B.) | | | | | | 2.) THE BARRIER OR FENCE ENCLOSING THE POOL AREA SHALL | | | BE AT LEAST FOUR FEET (4?) IN HEIGHT ABOVE GRADE. (ZLDR | | | S. 94-304 (D) (2) B.) | | | | | | 3.) A SEPARATE PERMIT WILL BE REQUIRED FOR THE POOL | | | FENCE/BARRIER ENCLOSURE. | | | | | | 4.) THE POOL DECK SHALL BE SETBACK AT LEAST TWO FEET | | | (2?) FROM THE REAR PROPERTY LINE. (ZLDR S. 94-305 (B) | | | (7)) | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT LINDA LOUIE | | | AT (561) 822-1442. | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |