Plan Review Details - Permit 13090516
Plan Review Stops For Permit 13090516
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2013-09-20 Cont ID  
Sent By rmcdouga Date 2013-09-20 Time 17:37 Rev Time 0.00
Received By rmcdouga Date 2013-09-20 Time 17:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-09-20 Cont ID  
Sent By rmcdouga Date 2013-09-20 Time 17:41 Rev Time 0.00
Received By rmcdouga Date 2013-09-20 Time 17:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-09-20 Cont ID  
Sent By rmcdouga Date 2013-09-20 Time 17:49 Rev Time 0.00
Received By rmcdouga Date 2013-09-18 Time 11:24 Sent To  
Notes
2013-09-18 11:24:59ROUTED TO ZONING

Review Stop P PLUMBING
Rev No 2 Status P Date 2013-10-16 Cont ID  
Sent By rmcdouga Date 2013-10-16 Time 13:46 Rev Time 0.00
Received By rmcdouga Date 2013-10-16 Time 13:46 Sent To  
Notes
2013-10-16 13:49:22MAIN DRAIN WAS CHANGED TO 3" TO ALLOW FOR MAXIMUM FLOW
 RATE OF THE PENTAIR VS 3050 PUMP THAT WAS SPECIFIED ON
 PLANS. CHANGE WAS RED-LINED ON PLANS.

Review Stop P PLUMBING
Rev No 1 Status F Date 2013-09-20 Cont ID  
Sent By rmcdouga Date 2013-09-20 Time 17:49 Rev Time 0.00
Received By rmcdouga Date 2013-09-20 Time 17:41 Sent To  
Notes
2013-09-20 17:49:372010 FBC
  
 DENIED BY PLUMBING
  
 1) THE INTELLIFLO VS 3050 POOL PUMP SPECIFIED ON SHEET
 2 OF THE PLANS HAS A MAXIMUM FLOW RATE OF 145 GPM WITH
 A 50' TDH. THE WATER VELOCITY IN THE 2-1/2 " SUCTION
 PIPING EXCEEDS THE 8 FEET PER SECOND ALLOWED BY FBCR
 4101.6.3. PLEASE CORRECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2013-10-16 Cont ID  
Sent By llouie Date 2013-10-16 Time 14:54 Rev Time 0.00
Received By llouie Date 2013-10-16 Time 14:54 Sent To  
Notes
2013-10-16 14:57:06PASSED WITH THE FOLLOWING PROVISOS:
  
 1.) POOL DECK SHALL BE SETBACK 2 FT. FROM THE PROPERTY
 LINE.
  
 2.) POOL BARRIER PERMIT IS REQUIRED. PERMIT SHALL BE
 APPROVED, AND BARRIER SHALL BE INSTALLED PRIOR TO C.O.
  
 CONTACT LINDA LOUIE @ (5610 822-1442 IF YOU HAVE
 QUESTIONS.

Review Stop Z ZONING
Rev No 1 Status F Date 2013-09-18 Cont ID  
Sent By llouie Date 2013-09-18 Time 15:53 Rev Time 0.00
Received By llouie Date 2013-09-18 Time 15:53 Sent To P
Notes
2013-09-18 15:55:59** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING. RESPOND TO THE COMMENTS
 IN WRITING AND/OR ON THE PLANS WHERE APPLICABLE:
  
 1.) THE SWIMMING POOL SHALL BE ENCLOSED BY A FENCE OR
 SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS
 BY PERSONS OTHER THAN THE OWNERS. (ZLDR S. 94-304 (D)
 (2) B.)
  
 2.) THE BARRIER OR FENCE ENCLOSING THE POOL AREA SHALL
 BE AT LEAST FOUR FEET (4?) IN HEIGHT ABOVE GRADE. (ZLDR
 S. 94-304 (D) (2) B.)
  
 3.) A SEPARATE PERMIT WILL BE REQUIRED FOR THE POOL
 FENCE/BARRIER ENCLOSURE.
  
 4.) THE POOL DECK SHALL BE SETBACK AT LEAST TWO FEET
 (2?) FROM THE REAR PROPERTY LINE. (ZLDR S. 94-305 (B)
 (7))
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT LINDA LOUIE
 AT (561) 822-1442.
  