Plan Review Details - Permit 13090510
Plan Review Stops For Permit 13090510
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-02-26 Cont ID  
Sent By shill Date 2014-02-26 Time 11:22 Rev Time 0.00
Received By shill Date 2014-02-26 Time 11:13 Sent To  
Notes
2014-02-07 15:04:45NEW INFORMATION SUBMITTED. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2013-09-24 Cont ID  
Sent By jwitmer Date 2013-09-24 Time 14:15 Rev Time 0.00
Received By jwitmer Date 2013-09-24 Time 14:03 Sent To  
Notes
2013-09-24 14:15:44BUILDING PLAN REVIEW
 PERMIT: 13090510
 ADD: 1325 N CONGRESS
 CONT: FINANCIAL BUILDING SERVICES
 TEL: (954)444-0785
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SEPT 24/ 2013
 ACTION: PROVISO
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) PLEASE SUBMIT MULLION PRODUCT APPROVAL. 2010 FBC-B
 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 COMPONENTS
 & CLADDING.FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE
 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS: (31)(B) MULLIONS.
  
 2) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 3) 1714.5.5.2 LOAD TRANSFER. MULLIONS SHALL BE DESIGNED
 TO TRANSFER THE DESIGN PRESSURE LOADS APPLIED BY THE
 WINDOW AND DOOR ASSEMBLIES TO THE ROUGH OPENING
 SUBSTRATE. 1714.5.5.4 STRUCTURAL SAFETY FACTOR.
 MULLIONS SHALL BE CAPABLE OF RESISTING A LOAD OF
 ONE-AND-ONE-HALF TIMES THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW AND DOOR ASSEMBLIES TO BE
 SUPPORTED WITHOUT EXCEEDING THE APPROPRIATE MATERIAL
 STRESS LEVELS. IF TESTED BY AN APPROVED LABORATORY, THE
 ONE AND ONE-HALF TIMES THE DESIGN PRESSURE LOAD SHALL
 BE SUSTAINED FOR 10 SECONDS, AND THE PERMANENT
 DEFORMATION SHALL NOT EXCEED 0.4 PERCENT OF THE MULLION
 SPAN AFTER THE ONE-AND-ONE-HALF TIMES DESIGN PRESSURE
 LOAD IS REMOVED.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-02-20 Cont ID  
Sent By rlecky Date 2014-02-20 Time 12:28 Rev Time 0.00
Received By rlecky Date 2014-02-20 Time 12:23 Sent To  
Notes
2014-02-07 15:03:58NEW ELECTRICAL PLAN SUBMITTED. JG.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2013-09-28 Cont ID  
Sent By wjolin Date 2013-09-28 Time 09:41 Rev Time 0.00
Received By wjolin Date 2013-09-28 Time 09:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-02-26 Cont ID  
Sent By shill Date 2014-02-26 Time 11:41 Rev Time 0.00
Received By shill Date 2014-02-06 Time 15:40 Sent To  
Notes
2014-02-07 15:41:08RESUBMITTAL SENT TO B1 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-10-09 Cont ID  
Sent By eschneid Date 2013-10-09 Time 13:27 Rev Time 0.00
Received By eschneid Date 2013-09-18 Time 08:04 Sent To  
Notes
2013-09-19 17:43:18B01

Review Stop Z ZONING
Rev No 2 Status P Date 2014-02-27 Cont ID  
Sent By eschneid Date 2014-02-13 Time 09:41 Rev Time 1.00
Received By eschneid Date 2014-02-13 Time 09:41 Sent To  
Notes
2014-02-13 10:03:41PASSED
  
 NO NEW MINOR AMENDMENT IS REQUIRED AS THE NEW ATM IS
 BEING BUILT INTO THE BUILDING, WITHIN THE BUILDING
 ENVELOPE.
  
2014-02-10 16:22:182/10/14

Review Stop Z ZONING
Rev No 1 Status F Date 2013-10-09 Cont ID  
Sent By eschneid Date 2013-10-09 Time 13:20 Rev Time 0.50
Received By eschneid Date 2013-10-09 Time 13:20 Sent To  
Notes
2013-10-09 13:26:46FAILED
  
 1) THE RECONFIGURATION OF THE SITE PLAN FOR THE NEW ATM
 LOCATION REQUIRES THAT A MINOR PLANNED DEVELOPMENT
 AMENDMENT IS SUBMITTED TO THE PLANNING DIVISION FOR
 APPROVAL. THIS WILL REPLACE THE AUGUST 4, 2010
 APPROVAL.
  
 2) ITEMS THAT WILL BE REVIEWED AS PART OF THE AMENDMENT
 AND SHOULD BE ADDRESSED AS PART OF THE SUBMITTAL:
  
 A. HOW WILL THE REMOVAL OF THE LANDSCAPE AFFECT BOTH
 THE OVERALL REQUIRED LANDSCAPE AND THE REQUIRED
 FOUNDATION PLANTING?
 B. WILL THE EXISTING ATM BE REMOVED?
 C. HOW WILL SECURITY OF ATM CUSTOMERS BE MAINTAINED.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
2013-09-20 11:10:499/20/13