Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-10-18 Cont ID  
Sent By jwitmer Date 2013-10-18 Time 14:19 Rev Time 0.00
Received By jwitmer Date 2013-10-18 Time 14:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-09-24 Cont ID  
Sent By jwitmer Date 2013-09-24 Time 07:59 Rev Time 0.00
Received By jwitmer Date 2013-09-24 Time 07:02 Sent To  
Notes
2013-09-24 07:59:03BUILDING PLAN REVIEW
 PERMIT: 13090504
 ADD: 460 S ROSEMARY # 180
 CONT: TO BE DETERMINED
 TEL: (561)856-6655
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: 9/24/2013
 ACTION: DENIED
  
 1) SHEET A-0.2 STRUCTURAL DESIGN CRITERIA,- WIND
 DESIGN:
 1A) WIND DESIGN INDICATES A 150 MPH 3 SECOND GUST, ASCE
 7-10 FOR RISK CATEGORY II BUILDINGS WE ARE LOCATED IN A
 170 MPH 3 SECOND GUST. 2010 FBC-B FIGURE 1609A
 1B) WIND DESIGGN INDICATES A "B" EXPOSURE , PLEASE
 REVISE TO "C" EXPOSURE
 1C) PRESSURES ARE LOW FOR FIGURING PRESSURES AT 45 FEET
 @ 10 SQ FT.
  
 2) SHEET A-1.0:
 2A) THE RESTROOMS DO NOT INDICATE THE DOOR SWING FOR
 EITHER RESTROOM. 2010 FL ACCESS CODE. 603.2.3 DOOR
 SWING.
 DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR
 CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE
 PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE.
  
 2B) PROVISO: NEW COOLER, NOT COVERED UNDER THIS PERMIT,
 REQUIRES A SEPEREATE PERMIT, REVIEW & FEES.
  
 3) NOTE # 13 FOR ENTRY DOORS IS BLANK, IF DOORS ARE
 BEING REPLACED, THEN PRODUCT APPROVALS ARE REQIURED FOR
 WIND AND LARGE MISSILE IMPACT TESTING. PLEASE NOTE THE
 OCCUPANT LOAD FOR THIS TENANT IS GREATER THAN 50, 2010
 FBC-B 1008.1.10 WILL REQUIRE PANIC HARDWARE.
  
 4) SHEET A-1.2 EXTERIOR WALL TYPES LISTED ON THE PLAN
 ARE NOT LISTED IN THE WALL PARTITION SCHEDULE.
 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-10-16 Cont ID  
Sent By skennedy Date 2013-10-16 Time 14:34 Rev Time 0.00
Received By skennedy Date 2013-10-16 Time 14:34 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2013-09-28 Cont ID  
Sent By wjolin Date 2013-09-28 Time 09:11 Rev Time 0.00
Received By wjolin Date 2013-09-28 Time 09:04 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2013-09-20 Cont ID  
Sent By lwagner Date 2013-09-20 Time 15:26 Rev Time 0.00
Received By lwagner Date 2013-09-20 Time 15:03 Sent To  
Notes
2013-09-20 15:26:36SEPARATE GAS PERMIT REQUIRED

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-10-16 Cont ID  
Sent By skennedy Date 2013-10-16 Time 14:36 Rev Time 0.00
Received By skennedy Date 2013-09-18 Time 18:20 Sent To  
Notes
2013-09-19 18:23:56C29

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2013-10-08 Cont ID  
Sent By hmoser Date 2013-10-08 Time 14:17 Rev Time 0.00
Received By hmoser Date 2013-10-08 Time 13:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-09-20 Cont ID  
Sent By lwagner Date 2013-09-20 Time 15:26 Rev Time 0.00
Received By lwagner Date 2013-09-20 Time 15:04 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status N Date 2013-12-19 Cont ID  
Sent By aaponte Date 2013-12-19 Time 16:30 Rev Time 0.00
Received By aaponte Date 2013-12-19 Time 16:30 Sent To  
Notes
2013-12-19 16:30:54REFLECTING CEILING ONLY.

Review Stop Z ZONING
Rev No 1 Status P Date 2013-09-25 Cont ID  
Sent By AAPONTE Date 2013-09-25 Time 15:49 Rev Time 0.00
Received By aaponte Date 2013-09-25 Time 15:49 Sent To  
Notes
2013-09-25 15:49:52PERMIT DOES NOT INCLUDE SIGN. A SEPARATE SIGN PERMIT
 WILL BE NEEDED.
2013-09-20 10:52:119/20/13