Plan Review Details - Permit 13090500
| Plan Review Stops For Permit 13090500 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-10-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-10-10 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-10-10 |
Time |
17:32 |
Sent To |
|
|
| Notes |
| 2013-10-10 18:35:02 | RE-ISSUE FOR EXPIRED PERMIT # 06040302 TO REPAIR | | | HURRICANE DAMAGE TO SCREEN ROOM. THE WORK WAS COMPLETED | | | BUT NEVER RECEIVED THE FINAL INSPECTION. THE ORIGINAL | | | PERMIT FOR SCREEN ROOM WAS # 04100547. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-10-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-10-08 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-10-08 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2013-10-08 15:37:14 | 2010 FBC | | | | | | RE-ISSUE STRUCTURAL REVIEW IS DENIED | | | | | | 1) SCREEN ENCLOSURES ARE CONSIDERED RISK CATEGORY I | | | WHICH EQUATES TO A 155 MPH VULT WINDSPEED FOR WEST PALM | | | BEACH AND THIS STRUCTURE IS LOCATED IN EXPOSURE | | | CATEGORY C. THE STRUCTURE IS REQUIRED TO BE DESIGNED TO | | | WITHSTAND THESE WINDLOADS. FBC 1604 | | | | | | 2) THE PLAN INFORMATION THAT WAS SUBMITTED IS NOT | | | ADEQUATE TO COMPLETE A STRUCTURAL REVIEW. SUBMIT (2) | | | SETS OF SIGNED AND SEALED ENGINEERED PLANS WITH SPAN | | | TABLES, SUPER GUTTER DETAILS, FOUNDATION DETAILS, | | | ANCHORING DETAILS, MATING DETAILS, K BRACING DETAILS, | | | ETC. FBC 2002.4 | | | | | | 3) FBC 2002.4.1 ALLOWS SCREEN ENCLOSURES TO BE DESIGNED | | | USING THE 2010 EDITION OF THE AAF GUIDE TO ALUMINUM | | | CONSTRUCTION IN HIGH WIND AREAS. IF THIS IS USED, | | | SUBMIT (2) SETS OF PLANS WITH COPIES OF THE SPAN | | | TABLES, SUPER GUTTER DETAILS, FOUNDATION DETAILS, | | | ANCHORING DETAILS, MATING DETAILS, K BRACING DETAILS, | | | ETC. THAT ARE TO BE USED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-10-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-10-10 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-10-10 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2013-10-10 13:28:42 | SENT TO R MCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-10-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-10-08 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-09-17 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2013-09-18 13:33:00 | SENT TO ZONING SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-09-24 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2013-09-24 |
Time |
07:36 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2013-09-24 |
Time |
07:31 |
Sent To |
|
|
| Notes |
|
|
|