| Plan Review Stops For Permit 13090405 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-10-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-10-22 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-10-21 |
Time |
18:56 |
Sent To |
Z |
|
| Notes |
| 2013-10-22 09:55:37 | BUILDING PROVISO | | | | | | 1) SUBMIT TWO COPIES OF THE ICC EVALUATION REPORT FOR | | | THE ICYNENE SPRAY FOAM INSULATION THAT WILL BE | | | INSTALLED. FBC R316 | | | | | | 2) THE RAS 117 CALCULATIONS FOR THE FLAT ROOF BASE | | | SHEET FASTENING FROM DANIEL J. MOSS, P.E. DO NOT HAVE | | | HIS HANDWRITTEN SIGNATURE (FACSIMILES ARE NOT | | | ACCEPTABLE) AS REQUIRED BY FAC 61G15-23.002. SUBMIT RAS | | | 117 CALCULATIONS WITH ORIGINAL SIGNATURES. ALSO THE | | | ADDRESS FOR THE CITY OF WEST PALM BEACH IS INCORRECT ON | | | THE DOCUMENT. PLEASE CORRECT THE ADDRESS TO 401 | | | CLEMATIS STREET WEST PALM BEACH FL 33401. | | | | | | 3) THE ENERGY CALCULATIONS THAT WERE SUBMITTED STILL | | | APPEAR TO BE IN ERROR. A 2 FT. OVERHANG IS STILL LISTED | | | AND THE STRUCTURE HAS NO OVERHANG. ALSO THE GLAZED AREA | | | AT THE NORTH ELEVATION DOES NOT APPEAR TO INCLUDE THE | | | TOTAL AREA OF THE (2) 5' X 8' GLAZED FRENCH DOORS AND | | | THE SPECIFIED AREAS ARE UNCLEAR. PLEASE SUBMIT TWO | | | REVISED SIGNED SETS. 2010 FBC ENERGY CONSERVATION | | | SECTIONS 405.5.1, 405.5.2 AND 405.5.3 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-09-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-27 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-09-24 |
Time |
18:50 |
Sent To |
|
|
| Notes |
| 2013-09-27 11:26:00 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) THE ENERGY CALCULATIONS CONTAIN SEVERAL ERRORS. | | | ENERGY CALCULATIONS ARE REQUIRED TO BE SPECIFIC TO THE | | | ORIENTATION OF THE BUILDING. WORST CASE CAN NOT BE | | | USED. THE FORM USES AN OVERHANG OF 2 FEET WHEN THERE | | | ISN'T ANY. A 50 GAL. WATER HEATER IS SPECIFIED ON THE | | | FORM AND THE PLANS SHOW A 30 GALLON. THE OWNER/AGENT IS | | | REQUIRED TO SIGN THE ENERGY FORMS. 2010 FBC ENERGY | | | CONSERVATION SECTION 405. | | | | | | 2) SHOW COMPLIANCE WITH FBC 318.6 WHICH REQUIRES | | | GUTTERS WITH DOWNSPOUTS THAT DISCHARGE ONE FOOT AWAY | | | FROM THE STRUCTURE WALLS FOR BUILDINGS WITH LESS THAN 6 | | | INCHES OF HORIZONTAL EAVE PROJECTION. | | | | | | 3) SHOW COMPLIANCE WITH FBC 806.1 FOR ATTIC / ROOF | | | VENTILATION. | | | | | | 4) SPECIFY THE FASTENING OPTION AND MAXIMUM DESIGN | | | PRESSURE FOR THE ASSEMBLY ON PAGE 29 OF THE GAF | | | RUBEROID PRODUCT APPROVAL (NOA NO. 09-0224.01) THAT | | | WILL BE USED. SUBMIT TWO COPIES OF SIGNED AND SEALED | | | RAS 117 CALCULATIONS FOR ENHANCED FASTENING AT | | | PERIMETER AND CORNER AREAS IN COMPLIANCE WITH | | | LIMITATION NUMBER 7 OF THE NOA. FBC R301.2.1 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-09-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-27 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-09-24 |
Time |
18:50 |
Sent To |
|
|
| Notes |
| 2013-09-27 09:50:01 | APPROVED PROVISIONALLY. PLANS HAVE BEEN RED-LINED. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2013-10-24 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2013-10-24 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2013-10-24 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2013-10-24 11:22:33 | GAVE TO R. MCDOUGAL |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-09-17 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2013-09-17 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2013-09-17 |
Time |
16:07 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-10-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-10-24 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-10-10 |
Time |
18:55 |
Sent To |
|
|
| Notes |
| 2013-10-10 18:55:39 | SENT TO R MCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-09-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-27 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-09-13 |
Time |
07:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2013-09-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-24 |
Time |
18:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-09-24 |
Time |
18:50 |
Sent To |
|
|
| Notes |
| 2013-10-25 12:47:55 | PLANS RETURNED WITH IMPACT STAMP | | 2013-09-24 18:51:41 | IMPACT FEE REVIEW REQUIRED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2013-10-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-10-22 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-10-21 |
Time |
18:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2013-09-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-27 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-09-24 |
Time |
18:50 |
Sent To |
|
|
| Notes |
| 2013-09-27 10:46:33 | 2010 FBC | | | | | | DENIED BY MECHANICAL | | | | | | 1) SUBMIT TWO SETS OF MECHANICAL PLANS THAT SHOW THE | | | LOCATION OF THE EQUIPMENT AND THE DUCT SYSTEM. SPECIFY | | | THE SUPPLY / RETURN DUCT AND GRILL LOCATIONS AND SIZES. | | | INDICATE THE CFMS AT EACH SUPPLY OUTLET. FBCR M1601.1 | | | AND CITY AMENDMENTS 107.3.5 | | | | | | 2) PROVIDE AN EQUIPMENT SCHEDULE ON THE MECHANICAL PLAN | | | THAT CORRESPONDS WITH THE EQUIPMENT SIZING | | | CALCULATIONS. FBCR M1401.3 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2013-10-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-10-22 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-10-22 |
Time |
07:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2013-09-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-27 |
Time |
06:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-09-27 |
Time |
06:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2013-09-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-09-27 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2013-09-27 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2013-09-27 09:53:41 | ROOFING PRODUCT APPROVAL NOA NO.09-0224.01 GAF RUBEROID | | | MODIFIED BITUMEN WAS SUBMITTED. SIGNED AND SEALED RAS | | | 117 CALCULATIONS ARE REQUIRED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2013-10-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2013-10-24 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2013-10-24 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-09-17 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2013-09-17 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2013-09-17 |
Time |
16:07 |
Sent To |
|
|
| Notes |
|
|