Plan Review Details - Permit 13090264
Plan Review Stops For Permit 13090264
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-09-24 Cont ID  
Sent By rmcdouga Date 2013-09-24 Time 08:53 Rev Time 0.00
Received By rmcdouga Date 2013-09-23 Time 13:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-09-16 Cont ID  
Sent By rmcdouga Date 2013-09-16 Time 16:50 Rev Time 0.00
Received By rmcdouga Date 2013-09-16 Time 12:13 Sent To  
Notes
2013-09-16 16:49:592010 FBC
  
 DENIED BY BUILDING
  
 1) SPECIFY THE SIZE AND TYPE OF ALL WINDOWS THAT ARE
 BEING REPLACED ON THE PLANS. (IE SINGLE HUNG,
 HORIZONTAL SLIDING) CITY AMENDMENTS 107.2.1 AND FBCR
 301.2.1
  
 2) SPECIFY THE SIZE OF THE ARCHED FIXED GLASS WINDOW
 ABOVE THE 52" X 50" WINDOW IN THE MASTER BEDROOM. FBCR
 301.2.1
  
 3) SHOW THAT THE NEW BEDROOM WINDOWS WILL COMPLY WITH
 FBCR 310 FOR EMERGENCY ESCAPE AND RESCUE OPENINGS.
  
 4) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE FOR THE
 STRUCTURAL MULLIONS SHOWN AT THE BEDROOM ADJACENT TO
 THE GARAGE AND FOR THE CONNECTION OF THE ARCHED F.G. TO
 THE MASTER BEDROOM WINDOW. DCA RULE 9N-3
  
 5) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE DOUBLE
 OUTSWING FRENCH DOORS WITH SIDELITES SPECIFIED ON THE
 PLANS AT THE FLORIDA ROOM. SPECIFY THE SIZE OF THE
 SIDELITES ON THE PLANS. DCA RULE 9N-3 AND FBCR 301.2.1
  
 6) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. ALSO
 INDICATE THE SPECIFIC WINDOW OR DOOR SIZE, TYPE OF
 GLASS, AND DESIGN PRESSURE LISTED IN THE NOA THAT IS TO
 BE INSTALLED. CITY AMENDMENTS 107.3.4.1 AND FBCR
 301.2.1
  
 7) THE 8' X 7' FIXED GLASS WINDOWS AT THE FLORIDA ROOM
 ARE LARGER THAN THE MAXIMUM SIZE OF 4' X 8' ALLOWED BY
 NOA NO. 13-0502.03 FOR THE PGT F.G. WINDOWS. PLEASE
 INDICATE HOW THIS WILL BE RESOLVED. DCA RULE 9N-3 AND
 FBCR 301.2.1
  
 8) THE WIND PRESSURES WERE NOT SPECIFIED FOR THE 52" X
 50" WINDOWS W/ ARCH AT THE MASTER BEDROOM AND KITCHEN.
 PLEASE CLARIFY.
  
 9) IN ORDER TO LESSEN REVIEW TIME, PLEASE SUBMIT A
 RESPONSE LETTER INDICATING HOW THE REVIEW COMMENTS HAVE
 BEEN ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2013-09-16 Cont ID  
Sent By rmcdouga Date 2013-09-16 Time 15:12 Rev Time 0.00
Received By rmcdouga Date 2013-09-16 Time 15:12 Sent To  
Notes
2013-09-16 15:24:51PASSED WITH EXCEPTION. RED-LINED PLANS.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-09-24 Cont ID  
Sent By rmcdouga Date 2013-09-24 Time 08:53 Rev Time 0.00
Received By rmcdouga Date 2013-09-19 Time 08:52 Sent To  
Notes
2013-09-20 08:52:28SENT TO R MCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-09-16 Cont ID  
Sent By rmcdouga Date 2013-09-16 Time 16:50 Rev Time 0.00
Received By rmcdouga Date 2013-09-10 Time 08:58 Sent To  
Notes
2013-09-11 08:59:28INCOMING SENT TO R19 BOX. JW

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2013-09-16 Cont ID  
Sent By rmcdouga Date 2013-09-16 Time 15:10 Rev Time 0.00
Received By rmcdouga Date 2013-09-16 Time 12:16 Sent To  
Notes
2013-09-16 15:12:25COMPLY WITH FBCR M1501- M1507 FOR KITCHEN AND BATHROOM
 EXHAUST.

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-09-16 Cont ID  
Sent By rmcdouga Date 2013-09-16 Time 12:15 Rev Time 0.00
Received By rmcdouga Date 2013-09-16 Time 12:13 Sent To  
Notes
2013-09-16 12:16:20REMOVE AND REPLACE FIXTURES IN THE SAME LOCATIONS.
 REPLACE TUB WITH SHOWER IN SMALL BATHROOM.

Review Stop Z ZONING
Rev No 1 Status P Date 2013-09-17 Cont ID  
Sent By ajones Date 2013-09-16 Time 19:09 Rev Time 0.00
Received By ajones Date 2013-09-16 Time 19:09 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved