Plan Review Details - Permit 13090195
| Plan Review Stops For Permit 13090195 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-09-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-09-18 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-09-18 |
Time |
10:00 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-09-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-09-10 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-09-10 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2013-09-10 14:10:44 | BUILDING PLAN REVIEW | | | REVISION: 13090195 | | | PERMIT: 13080592 | | | ADD: 3800 WASHINGTON RD | | | CONT: JTL AIR CONDITIONING & REFRIGARATION | | | TEL: (954)448-1360 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: SEPT 10/ 2013 | | | ACTION: DENIED | | | | | | 1) THIS SHAFT IS LOCATED IN A HIGHRISE BUILDING, THE | | | MINIMUM BUILDING TYPE IB, FBC-B 503. THE 2010 FBC-B | | | 708.12 ENCLOSURES AT THE TOP. A SHAFT ENCLOSURE THAT | | | DOES NOT EXTEND TO THE UNDERSIDE OF THE ROOF SHEATHING, | | | DECK OR SLAB OF THE BUILDING SHALL BE ENCLOSED AT THE | | | TOP WITH CONSTRUCTION OF THE SAME FIRE RESISTANE AS THE | | | TOP MOST FLOOR PENETRATION BY THE SHAFT, BUT NOT LESS | | | THAN THE FIRE-RESISTANCE RATING REQUIRED FOR THE SHAFT | | | ENCLOSURE. FBC-B TABLE 601 REQUIRES A 2 HR FLOOR RAING. | | | | | | 2) PLANS DO NOT SHOW THE A/C DUCT PENETRATING THE TOP | | | OF THE SHAFT, FIRE DAMPERS WILL ALSO BE REQUIRED AND | | | STEEL FLANGES TO TRANSITION FROM THE FLOOR PLATE TO | | | METAL DUCT. FBC-B 716.5.3. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2013-09-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-09-17 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2013-09-17 13:59:25 | RESUBMITTAL SENT TO JIM'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
wlehnhar |
Date |
2013-09-09 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2013-09-09 13:04:36 | MECHANICAL |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2013-09-20 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2013-09-20 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2013-09-20 |
Time |
14:04 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |