| Plan Review Stops For Permit 13090031 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2013-11-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-11-07 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-11-07 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2013-11-07 13:54:00 | BUILDING PLAN REVIEW | | | PERMIT: 13090031 | | | ADD: 615 N DIXIE HWY | | | CONT: BUTLER CONSTRUCTION | | | TEL: (561))832-9700 | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE;THURS. NOV. 07/ 2013 | | | ACTIONBUILDING PROVISO | | | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | | | | | | 1) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 2) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C): STOREFRONTS, CURTAIN WALLS, WALL LOUVERS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | | (E) SHUTTERS | | | (F) PRE-ENGINEERED A/C STANDS | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-09-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-09-25 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-09-24 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2013-09-25 11:31:24 | BUILDING PLAN REVIEW | | | PERMIT: 13090031 | | | ADD: 615 N DIXIE HWY | | | CONT: BUTLER CONSTRUCTION | | | TEL: (561))832-9700 | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED SEPT 25/ 2013 | | | ACTION: DENIED | | | | | | 1) STRUCTURAL SHEET S-2 INDICATES A SOILS REPORT BY | | | TIERRA WAS COMPLETED ON JUNE 13/ 2013, PLEASE PROVIDE 2 | | | SIGNED AND SEALED ORIGINALS. 2010 FBC-B 1803.5.2.. | | | | | | 2) STRUCTURAL SHEET S-1 THE WALLS WITH MARKER TAGS MW, | | | & MW-2 DO NOT INDICATE THE USE OF ANY VERTICAL STEEL, | | | SIZE , SPACING AND OR QUANTITY OF STEEL IN THE | | | BLOCKWORK. 2010 FBC-B 2108.2/ 3.3.3.3 | | | 530 ASCE. | | | | | | 3) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 4) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C): STOREFRONTS, CURTAIN WALLS, WALL LOUVERS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | | (E) SHUTTERS | | | (F) PRE-ENGINEERED A/C STANDS | | | | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-10-17 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-10-17 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-10-17 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2013-10-17 17:21:33 | THE FOLLOWING CORRECTIONS/ADJUSTMENTS NEED TO BE | | | ADDRESSED: | | | 1. TAKING INTO ACCOUNT THE ADJUSTMENT FACTORS OF NEC | | | 310.15(B)(2)(A) REQUIRED FOR FOUR CURRENT CARRYING | | | CONDUCTORS IN A RACEWAY AND THE VALUES AS PER NEC | | | 310.16, THIS FEEDER WILL ONLY WORK IF USING 90 DEGREE | | | INSULATION. | | | THE LESSER 75 DEGREE COLUMN LIMITS 500 MCM TO 380 AMP | | | AND APPLYING THE CORRECTION FACTORS OF 310.15 OF 80% | | | REDUCES THE AMPACITY OF THE CONDUCTOR TO ONLY 304 AMP. | | | | | | MAKE THE CORRESPONDING NOTES ON THE DRAWINGS |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2013-11-06 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2013-11-06 |
Time |
|
Rev Time |
0.25 |
| Received By |
mgonzale |
Date |
2013-11-06 |
Time |
|
Sent To |
B |
|
| Notes |
| 2013-11-06 15:35:25 | PASSED |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2013-10-11 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2013-10-11 |
Time |
|
Rev Time |
0.25 |
| Received By |
mgonzale |
Date |
2013-10-11 |
Time |
|
Sent To |
Z |
|
| Notes |
| 2013-10-11 08:19:15 | A SEPARATE SUBMITTTAL IS REQUIRED FOR ENGINEERING. | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES AND PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2013-09-11 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-09-11 |
Time |
18:39 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-09-11 |
Time |
18:07 |
Sent To |
|
|
| Notes |
| 2013-09-11 18:39:36 | 615 NORTH DIXIE HIGHWAY | | | PERMIT #13090031 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | GENERAL: PROVIDE AN EXTERIOR KEY SAFE TO ALLOW | | | EMERGENCY RESPONDERS NON-FORCIBLE ENTRY INTO THE | | | BUILDING DURING NON-BUSINESS HOURS. A KEY SAFE CAN BE | | | ORDERED FROM WWW.KNOXBOX.COM. | | | | | | GENERAL: PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT | | | DOORS WITH EXIT SIGNS. | | | | | | WESLEY JOLIN | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-11-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-11-12 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-10-23 |
Time |
12:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-10-17 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2013-10-17 |
Time |
18:56 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2013-09-03 |
Time |
17:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
N |
Date |
2013-11-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-11-12 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-11-12 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2013-11-12 16:26:08 | PALM BEACH COUNTY IMPACT FEE ASSESSMENT: | | | MU-2013-023975-0000 | | | $53,851.40 | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2013-11-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-11-07 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-11-07 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2013-11-07 13:55:44 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2013-09-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-09-25 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-09-25 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2013-09-25 11:31:47 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2013-11-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-11-12 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-11-12 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2013-11-12 09:51:35 | PASS PROVISO | | | PROVIDE NOA FOR CONDENSER | | | STAND BY FIRST INSPECTION | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2013-10-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-10-11 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-10-11 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2013-10-11 14:54:01 | PLANS DENIED | | | 1) REFER TO SECTION 503.2.4.4 SHUT OFF DAMPER CONTROLS. | | | (FOR FRESH AIR AND EXHAUST) 2010 FLORIDA ENERGY CODE. | | | 2) PROVIDE NOA FOR CONDENSER STAND. | | | PER SECTION 107 FBC 2010 | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2013-10-29 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-10-29 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-10-29 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2013-10-29 13:33:20 | REVISION REQUIRED | | | | | | ***PROVISO*** | | | THE EVEVATOR SUMP PUMP SHALL BE INDIRECTLY | | | CONNECTED TO THE SANITARY SYSTEM. 301.6 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2013-09-17 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-09-17 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-09-17 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2013-09-17 10:33:59 | FBC 2010 ACCESSIBILITY CODE | | | FBC 2010 PLUMBING REVIEW #1 | | | DENIED: | | | | | | 1. SHEET P0.1: ON THE SANITARY ISO. THE 2ND FLOOR SINK | | | IS REQUIRED TO CONNECT DOWNSTREAM OF THE RESTROOM WET | | | VENT FOR THE WATER CLOSET & LAV. | | | 909.1 HORIZONTAL WET VENT PERMITTED. | | | ANY COMBINATION OF FIXTURES WITHIN TWO BATHROOM GROUPS | | | LOCATED ON THE SAME FLOOR LEVEL IS PERMITTED TO BE | | | VENTED BY A HORIZONTAL WET VENT. THE WET VENT SHALL BE | | | CONSIDERED THE VENT FOR THE FIXTURES AND SHALL EXTEND | | | FROM THE CONNECTION OF THE DRY VENT ALONG THE DIRECTION | | | OF THE FLOW IN THE DRAIN PIPE TO THE MOST DOWNSTREAM | | | FIXTURE DRAIN CONNECTION TO THE HORIZONTAL BRANCH | | | DRAIN. EACH WET-VENTED FIXTURE DRAIN SHALL CONNECT | | | INDEPENDENTLY TO THE HORIZONTAL WET VENT. ONLY THE | | | FIXTURES WITHIN THE BATHROOM GROUPS SHALL CONNECT TO | | | THE WET-VENTED HORIZONTAL BRANCH DRAIN. ANY ADDITIONAL | | | FIXTURES SHALL DISCHARGE DOWNSTREAM OF THE HORIZONTAL | | | WET VENT. | | | | | | 2. SHEET P0.1: ON THE SANITARY ISO. THE SOIL STACK FOR | | | THE 2ND FLOOR FIXTURES IS RUN THROUGH THE 1ST FLOOR | | | RESTROOM. | | | 909.1 HORIZONTAL WET VENT PERMITTED. | | | ANY COMBINATION OF FIXTURES WITHIN TWO BATHROOM GROUPS | | | LOCATED ON THE SAME FLOOR LEVEL IS PERMITTED TO BE | | | VENTED BY A HORIZONTAL WET VENT... | | | | | | 3. SHEET P0.1: THE EVEVATOR SUMP PUMP IS NOT PERMITTED | | | TO BE DIRECTLY CONNECTED TO THE SANITARY SYSTEM. | | | 301.6 PROHIBITED LOCATIONS. | | | PLUMBING SYSTEMS SHALL NOT BE LOCATED IN AN ELEVATOR | | | SHAFT OR IN AN ELEVATOR EQUIPMENT ROOM. | | | | | | EXCEPTION: FLOOR DRAINS, SUMPS AND SUMP PUMPS SHALL BE | | | PERMITTED AT THE BASE OF THE SHAFT, PROVIDED THAT THEY | | | ARE INDIRECTLY CONNECTED TO THE PLUMBING SYSTEM AND | | | COMPLY WITH SECTION 1003.4. | | | | | | 4. SHEET P0.1: THE EVEVATOR SUMP PUMP WILL REQUIRE AN | | | APPROVED OIL ALARM SYSTEM. | | | 1003.4 OIL SEPARATORS REQUIRED. | | | AT REPAIR GARAGES, CAR-WASHING FACILITIES, AT FACTORIES | | | WHERE OILY AND FLAMMABLE LIQUID WASTES ARE PRODUCED AND | | | IN HYDRAULIC ELEVATOR PITS, SEPARATORS SHALL BE | | | INSTALLED INTO WHICH ALL OIL-BEARING, GREASE-BEARING OR | | | FLAMMABLE WASTES SHALL BE DISCHARGED BEFORE EMPTYING | | | INTO THE BUILDING DRAINAGE SYSTEM OR OTHER POINT OF | | | DISPOSAL. | | | | | | EXCEPTION: AN OIL SEPARATOR IS NOT REQUIRED IN | | | HYDRAULIC ELEVATOR PITS WHERE AN APPROVED ALARM SYSTEM | | | IS INSTALLED. | | | | | | 5. SHEET P0.1: THE WATER PIPE ISO. SHOWS 1" WATER | | | SERVICE. THE PLUMBING FIXTURE SCHEDULE CALLS FOR FLUSH | | | VALVE TYPE WATER CLOSETS. FROM TABLE 603.1, 1 1/2" PIPE | | | WOULD BE REQUIRED OR PLEASE PROVIDE CALCULATIONS. | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2013-11-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-11-07 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-11-07 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2013-11-07 13:55:20 | ROOFING/ BUILDING PLAN REVIEW | | | PERMIT: 13090031 | | | ADD: 615 N DIXIE HWY | | | CONT: BUTLER CONSTRUCTION | | | TEL: (561))832-9700 | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE;THURS. NOV. 07/ 2013 | | | ACTIONBUILDING PROVISO | | | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | | | | | | 1) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 2) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES | | | | | | | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2013-11-01 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2013-11-01 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2013-11-01 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2013-11-01 16:16:50 | PROVISO: | | | 1. LANDSCAPE DRAWINGS SHALL BE UPDATED TO REFLECT THE | | | CONDITIONS OF APPROVAL FOR THE SALE OF THE CITY-OWNED | | | PROPERTY. | | | 2. ALL THE APPROVALS FROM FDOT FOR THE DECELARATION | | | LANE AND CURB CUT ALONG QUADRILLE BLVD SHALL BE | | | OBTAINED BEFORE CO CAN BE ISSUED. | | | 3. UNITY OF TITLE FOR 615 N DIXIE HWAY WILL BE REQUIRED | | | BEFORE FINAL CO. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439. | | | | | 2013-10-30 14:49:13 | 10/29/13 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-10-15 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2013-10-15 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2013-10-15 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2013-10-15 13:20:33 | 1. PRIVATE OPEN SPACE SHALL BE MINIMUM 12% OF THE LOT | | | AREA. | | | 2. PLEASE INDICATE PARKING CALCULATION SEPARATE FOR | | | EACH PARCEL, AND MAKE A NOTE REGARDING THE LOCATION OF | | | THE 13 SPACES REQUIRED FOR 615 N. DIXIE HWAY OFF-SITE | | | AT 415 5TH STREET. PARKIGN REQUIREMENT IS 2.5 | | | SPACES/1000SF. | | | 3. TEXT ON HISTORIC MARKER SHALL BE APPROVED BY | | | HISTORIC PRESERVATION PLANNER. PLEASE SUBMIT DRAFT. | | | 4. PLEASE SUBMIT A COPY OF THE FDOT APPROVAL FOR THE | | | DECELARATION LANE AND THE PROPOSED LANDSCAPE ON THE | | | QUADRILLE ROW. PORTION OF THE NEW SIDEWALK WILL BE NOW | | | IN PRIVATE PROPERTY. A CONDITION SHALL BE INCLUDED TO | | | REQUIRE THE SIDEWALK TO BE OPEN TO THE PUBLIC. IF THE | | | SIDEWALK IS GOING TO BE DEDICATED TO FDOT, PLEASE SHOW | | | BOUNDARIES. | | | 5. SIGNAGE SHALL BE SUBMITTED AS A SEPARATE PERMIT (SEC | | | 94-110(C)). | | | 6. PLEASE CONFIRM ROOF TREATMENT COMPLIES WITH CODE | | | REQUIREMENTS FOR SOLAR REFLECTANCE INDEX IN SEC 94-109 | | | (ROOF TREATMENT). | | | 7. PLEASE CONFIRM PROPOSED GLASS IS NOT REFLECTIVE. | | | 8. CHANGES ON LANDSCAPE ACCORDING TO CITY COMMISSION | | | APPROVAL SHALL BE REFLECTED ON PERMIT SET. | | | 9. PLEASE INDICATE WHERE IS THE LOCATION OF THE SCREEN | | | WALL DETAIL AS NUMBER 5 IN PAGE A-0.1. | | | 10. A RESTRICTIVE COVENANT FOR THE OFF-SITE PARKING AND | | | A CROSS ACCESS AGREEMENT WILL BE REQUIRED BEFORE FINAL | | | CO CAN BE ISSUED. | | | 11. UNITY OF TITLE WILL BE REQUIRED FOR THE 615 N. | | | DIXIE HWAY AND SLIVER PROPERTY. | | | 12. ROOF TOP EQUIPMENT SCREEN DETAIL IS MISLABELED ON | | | ROOF PLAN. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822 1439. | | | | | | | | 2013-09-05 09:28:05 | 9/5/13 |
|
|