| 2013-09-11 07:52:32 | 2010 FBC |
| | |
| | DENIED BY BUILDING |
| | |
| | 1) THE STRUCTURE IS LOCATED IN A SPECIAL FLOOD HAZARD |
| | AREA WITH AN A5 FLOOD ZONE DESIGNATION. THE MINIMUM |
| | BASE FLOOD ELEVATION IS 7' 6", WHICH INCLUDES A 6" |
| | FREEBOARD ESTABLISHED BY CITY OF WEST PALM BEACH |
| | ORDINANCE. THE VALUE OF THE PROPOSED WORK WHEN ADDED TO |
| | PREVIOUS WORK DONE TO THE STRUCTURE IS OVER 50 PERCENT |
| | OF THE VALUE OF THE STRUCTURE BASED ON THE PALM BEACH |
| | COUNTY PROPERTY APPRAISER. THEREFORE, THIS IS |
| | CONSIDERED A SUBSTANTIAL IMPROVEMENT AND THE ENTIRE |
| | STRUCTURE IS REQUIRED TO COMPLY WITH THE REQUIRED |
| | ELEVATION PER FEMA AND CITY ORDINANCE. SUBMIT AN |
| | ELEVATION CERTIFICATE THAT SHOWS THE EXISTING STRUCTURE |
| | AND EQUIPMENT ARE IN COMPLIANCE OR INDICATE HOW IT WILL |
| | BE BROUGHT INTO COMPLIANCE. |
| | |
| | 2) ON SHEET A100, THE 2007 FBC W/2010 AMENDMENTS IS |
| | SPECIFIED. THIS IS INCORRECT. THE APPLICABLE CODE IS |
| | THE 2010 FBC EXISTING BUILDING. THIS IS A LEVEL 2 |
| | ALTERATION. PLEASE CORRECT THE DESIGN DATA BOX AND |
| | GENERAL NOTES #1 AND #10. |
| | |
| | 3) ALSO ON SHEET A100 THE DESIGN DATA BOX INCORRECTLY |
| | SPECIFIES TYPE 1-A CONSTRUCTION. THIS STRUCTURE IS A |
| | SINGLE FAMILY DWELLING AND IS TYPE V-B CONSTRUCTION. |
| | PLEASE CORRECT. |
| | |
| | 4) GENERAL NOTE #1 SPECIFIES COMPLIANCE WITH AMENDMENTS |
| | ADOPTED BY THE TOWN OF PALM BEACH. THIS PROJECT IS |
| | LOCATED IN THE CITY OF WEST PALM BEACH, THEREFORE, ONLY |
| | THE CITY OF WEST PALM BEACH AMENDMENTS WOULD APPLY. |
| | PLEASE CORRECT. |
| | |
| | |