Plan Review Details - Permit 13081099
Plan Review Stops For Permit 13081099
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2014-01-16 Cont ID  
Sent By shill Date 2014-01-16 Time 19:39 Rev Time 0.00
Received By shill Date 2014-01-16 Time 19:39 Sent To  
Notes
2014-01-16 19:49:51****PROVISOS****
  
 1. FINISHED CONSTRUCTION ELEVATION CERTIFICATE
 (REQUIRED PRIOR TO FINAL INSPECTION) IS TO BE A SIGNED,
 SEALED DATED ORIGINAL PER FLORIDA STATUTE 472.025.
 SECOND PAGE IS TO INCLUDE AN ORIGINAL SIGNATURE. NOT
 PHOTOCOPIES OR STAMPS WILL BE ACCEPTED.
  
 2. ITEM C2 E, MACHINERY OR EQUIPMENT SERVICING THE
 BUILDING, IS TO BE AT A MINIMUM ELEVATION OF 7'6".
  
 3. IN ORDER TO AVOID C.O. DELAYS, SUBMIT THE "FINISHED
 CONSTRUCTION" SURVEY AS A SUBMITTAL TO PLAN REVIEW
 AFTER THE FOLLOWING HAS BEEN COMPLETED, BUT BEFORE A
 FINAL INSPECTION HAS BEEN SCHEDULED:
  
 ALL MACHINERY AND/OR EQUIPMENT SUCH AS FURNACES, WATER
 HEATERS, HEAT PUMPS, AIR CONDITIONERS AND THEIR
 ASSOCIAED EQUIPMENT HAVE BEEN INSTALLED
  
 THE GRADING AROUND THE BUILDING HAS BEEN COMPLETED
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2014-01-13 Cont ID  
Sent By shill Date 2014-01-13 Time 14:24 Rev Time 0.00
Received By shill Date 2014-01-13 Time 14:24 Sent To  
Notes
2014-01-13 14:51:55****CORRECTIONS****
 ****ELEVATION CERTIFICATE PREPARED BY ROBERT A BUGGEE
 DATED 1/8/14, "BUILDING UNDER CONSTRUCTION" ****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. REVISE EC TO REFERENCE THE STRUCTURE THAT IT
 REPRESENTS. PHOTOS SHOW THE EXISTING HOUSE AS WELL AS
 THE BUILDING UNDER CONSTRUCTION. SEE EC INSTRUCTIONS;
 ALL REFERENCES ARE TO "THE BUILDING" SINGULAR.
 THEREFORE, THE ELEVATION CERTIFICATE SHOULD BE FOR ONE
 STRUCTURE ONLY. THIS EC SHOULD BE FOR THE BUILDING
 UNDER CONSTRUCTION (CABANA). PLEASE REVISE, INCLUDING
 THE ITEMS IN C2.
  
 2. A7 BUILDING DIAGRAM NUMBER IS 1A, BUT 1A IS SLAB ON
 GRADE; ISN'T THIS A STEM WALL? REVISE EC OR EXPLAIN.
  
 3. A9 INDICATES A GARAGE; SEE ITEM 1. IT APPEARS THAT
 THIS IS FOR THE MAIN HOUSE. CABANA PLANS DO NOT SHOW A
 GARAGE.
  
 4. B1, INCLUDE COMMUNITY NUMBER.
  
 5. MECHANICAL EQUIPMENT IN SECTION C2 MUST BE 7.5'
 MINIMUM. NOTE THAT THIS IS TO BE THE ELEVATION OF THE
 MECHANICAL EQUIPMENT, NOT THE SLAB. IF STANDS ARE
 PROPOSED, THIS CAN BE EXPLAINED IN THE "COMMENTS"
 SECTION.
  
 6. SECTION D, PLEASE CHECK APPLICABLE BOXES. AS
 LAT/LONG WERE PROVIDED BY A SURVEYOR, THE SOURCE IS TO
 BE NOTED IN THE "COMMENTS" SECTION PER INSTRUCTIONS.
  
 7. PAGE 2, INCORRECT JOB ADDRESS, PLEASE REVISE.
  
 8. B4 IS TO INCLUDE MAP NUMBER AS WELL AS PANEL NUMBER.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status N Date 2014-01-02 Cont ID  
Sent By skennedy Date 2014-01-02 Time 15:33 Rev Time 0.00
Received By skennedy Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2013-11-06 Cont ID  
Sent By jgomez Date 2013-11-06 Time 15:06 Rev Time 0.00
Received By jgomez Date 2013-11-06 Time 15:06 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-10-24 Cont ID  
Sent By jgomez Date 2013-10-23 Time 17:56 Rev Time 0.00
Received By jgomez Date 2013-10-23 Time 17:55 Sent To  
Notes
2013-10-25 09:13:5610-25/13 TALKED TO ANTHONY SABA. HE SAID OK TO DO
 PROVISO. JG.
2013-10-23 18:02:16 
 BUILDING REVIEW APPROVED WITH PROVISO:
 * 1- SURVEY SUBMITTED: NEED SURVEYOR'S ORIGINAL
 SIGNATURE, NOT COPY. CHAPTER 472 FL. ST.
 ** 2- REVISE ENERGY CALCULATIONS SUBMITTED AND
 COORDINATE WITH FLOOR PLANS: *A)PROVIDE LEGIBLE FRONT
 PAGE. **B)THERE IS NOT CRAWL SPACE. ***C)ROOF DECK IS
 NOT INSULATED. ****D)THERE IS AN ATTIC (SEE DEFINITION
 OF ATTIC). *****E) WHY GABLE AREA ON PAGE 2 OF 5 IS
 24FT IF THIS IS A FLAT ROOF?. ******F)REVISE THE
 WINDOWS OVERHANG SEPARATION ON PAGE 3 OF 5 TO MATCH
 PLANS.
 ***3- REVISE TYPICAL WALL SECTION TO SHOW WALL
 INSULATION VALUE AS SPECIFIED ON THE ENERGY
 CALCULATIONS(R-5).
 ****4- SUBMIT ENGINEER RAS 117 CALCULATIONS WITH
 ENGINEER'S ORIGINAL SEAL AND SIGNATURE. CHAPTER 471 FL.
 ST.
 *****5- PROVIDE PRODUCT APPROVAL FOR WINDOW MULLION FOR
 DOUBLE SLIDING WINDOWS ON SOUTH ELEVATION.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-09-16 Cont ID  
Sent By jgomez Date 2013-09-16 Time 17:41 Rev Time 0.00
Received By jgomez Date 2013-09-16 Time 17:40 Sent To  
Notes
2013-09-16 17:55:40RESIDENTIAL (R3) ADDITION, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- A) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR
 FIRE RATED WALLS AND ROOF OVERHANGS AS REQUIRED BY
 TABLE R302.1 OF 2010 FBC-RESIDENTIAL FOR PROPOSED
 BUILDING THAT IS LOCATED @2'-0" FROM PROPERTY LINE.
  
 B) OPENINGS NOT ALLOWED IF DISTANCE TO PROPERTY LINE IS
 LESS THAN 3'-0". REVISE PLANS AS REQUIRED. TABLE R302.1
  
 2- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) TO VERIFY IF IMPACT FEES ARE
 REQUIRED. BRING BACK COUNTY STAMPED PLANS AND COPY OF
 PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
  
 3- SHEET SP: REVISE THE FLOOD ZONE. BUILDING IS LOCATED
 IN FLOOD ZONE "A5" NOT "AE". SEC. R322.1.
  
 4- SURVEY SUBMITTED:
 A) REVISE FLOOD ZONE. BUILDING SI LOCATED IN FLOOD ZONE
 "A5" NOT "AE".
 B) NEED SURVEYOR ORIGINAL SIGNATURE, NOT COPY AS
 REQUIRED BY CHAPTER 472 FLORIDA STATUTE.
  
 5- SHEET #1: A) SPECIFY SIZE OF ROOF DRAINS (SCUPPERS)
 AND RAIN LEADERS. SEC. 107.2.1 CITY AMENDMENTS TO FBC.
  
 B) LOCATION OF ROOF DRAINAGE (SCUPPERS) SHOWN ON THE
 PROPOSED ROOF FRAMING PLAN IS ON THE OPPOSITE SIDE OF
 THE ROOF SLOPE SHOWN ON THE PROPOSED ROOF PLAN. REVISE
 AS REQUIRED TO MATCH. SEC. R903.4.
  
 C) NEED TO SPECIFY OVERFLOW SCUPPERS AS REQUIRED BY
 SEC. R903.4.1 AND SPECIFY SIZE.
  
 D) SPECIFY SIZE OF GOOSE-NECK ROOF VENTS. SEC. R806.
  
 E) SPECIFY CONNECTORS FOR ROOF TRUSSES. SEC. 107.2.1
 CITY AMENDMENTS.
  
 6- SHEET #2: A) PROVIDE SPECIFICATIONS FOR ROOF
 SHEATHING FASTENING AS REQUIRED BY SEC. R803.2.3.1.
 SPECIFY 8D RING SHANK NAILS MIN. AND ROOF ZONE TO HAVE
 8D RING SHANK NAILS AT 4"O.C.
  
 B) PROVIDE COMPLETE SPECIFICATIONS AND DETAILS
 (INCLUDING SIZES) FOR ALL LINTELS ABOVE WINDOWS AND
 DOORS. SEC. R606.10
  
 C) CLARIFY WHERE ARE THE RAIN LEADERS LEADING TO.
 ELEVATIONS SHOW LIKE RAIN LEADERS ARE BURIED. RAIN
 LEADERS NEED TO DISCHARGE AT LEAST 1 FOOT AWAY FROM
 WALL. SEE SEC. R318.6
  
 7- ENGINEER OF RECORD TO UPDATE THE FIRM CERTIFICATE OF
 AUTHORIZATION #26154 WITH THE FLORIDA DEPARTMENT OF
 BUSINESS & PROFESSIONAL REGULATION AS REQUIRED BY
 CHAPTER 471 OF FLORIDA STATUTE.
  
 8- ENERGY CALCULATIONS SUBMITTED:
 A) NEED TO BE CERTIFIED AND DATED BY THE PERSON WHO
 PREPARED THEM AT THE BOTTOM OF FORM.
  
 B) NEED TO BE CERTIFIED AND DATED BY THE OWNER/AGENT AT
 THE BOTTOM OF FORM.
  
 C) REVISE THE AREA WEIGHTED AVERAGE OVERHANG DEPTH TO
 MATCH PLANS. DOORS ARE CONSIDERED GLASS ALSO AND THERE
 IS NO OVERHANG ABOVE DOORS. SEE ELEVATIONS AND PRODUCT
 APPROVALS SUBMITTED.
  
 D) THERE IS NOT KITCHEN IN THIS CABANA. SEE PLANS AND
 REVISE PAGE 2 OF 5.
  
 E) REVISE ROOF MATERIAL SHOWN ON PAGE 2 OF 5 TO MATCH
 PLANS. FLAT ROOF NOT SHINGLES.
  
 F) REVISE DOOR TYPE AND SIZES ON PAGE 3 OF 5 TO MATCH
 PLANS AND PRODUCT APPROVALS. THERE ARE NO WOOD DOORS.
  
 9- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) FLAT ROOF ASSEMBLY TO BE INSTALLED. AND, CLEARLY
 IDENTIFY WHICH APPROVED ASSEMBLY IS GOING TO BE
 INSTALLED AND PROVIDE SIGNED AND SEALED RAS 117
 CALCULATIONS FOR NAIL ENHANCING AT PERIMETER AND CORNER
 AREAS AS REQUIRED TO MEET THE DESIGN PRESSURES OF SEC.
 R301.
  
 B) ALL STRUCTURAL CONNECTORS (SIMPSON OR USP) SPECIFIED
 FOR ROOF TRUSSES. ***NOTE; PROVIDE ONLY THE PRODUCT
 APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED
 CONNECTOR.
  
 10- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 OF CITY AMENDMENTS.
  
 ***NOTE: PROPERTY IS LOCATED IN FLOOD ZONE A5.
 ELEVATION CERTIFICATES ARE REQUIRED DURING CONSTRUCTION
 FOR BUILDING AND EQUIPMENT. MIN. FINISH FLOOR ELEVATION
 REQUIRED IS 7'-6".
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2014-01-02 Cont ID  
Sent By skennedy Date 2014-01-02 Time 15:33 Rev Time 0.00
Received By skennedy Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-11-04 Cont ID  
Sent By albarran Date 2013-11-04 Time 14:21 Rev Time 0.00
Received By albarran Date 2013-11-04 Time 13:38 Sent To I
Notes
2013-11-04 14:21:49SENT TO SH DESK
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-10-16 Cont ID  
Sent By dharvey Date 2013-10-16 Time 10:42 Rev Time 0.00
Received By dharvey Date 2013-10-16 Time 10:07 Sent To  
Notes
2013-10-16 11:15:57THE FOLLOWING ITEMS SHALL BE ADDRESSED FOR A SUCCESSFUL
 ELECTRICAL PLANS REVIEW:
 1. PROVIDE AN ELECTRICAL RISER DIAGRAM SHOWING PROPER
 WIRE SIZE AND GROUNDING.
 2. INDICATE ON THE DRAWINGS THE LOCATION OF BOTH, THE
 ELECTRIC METER AND THE ELECTRICAL PANEL.
 3. INCLUDE ON THE DRAWING THE LOCATION OF THE REQUIRED
 SMOKE DETECTORS.
 4. THE ELECTRICAL LOAD CALCS DUE SHOW A DRYER, BUT THEY
 FAIL TO SHOW THE WASHER CIRCUIT OR LOAD.
 5. SHOW THE LOCATION OF THE WASHER & DRYER ON THE PLANS
 6. LOAD CALCS INDICATE THE LOAD AND CIRCUIT FOUR THE
 WATER HEATER BUT THE LOCATION OF SAME IS NOT ON THE
 PLANS.
 7. NEC 210.52, REQUIRES THAT EVERY USABLE WALL SPACE
 GREATER THEN 24" HAVE AN ELECTRICAL OUTLET.
  
 SENT BACK TO BIN WAITING FOR CORRECTIONS BY: MA

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2013-10-24 Cont ID  
Sent By fmittner Date 2013-10-24 Time 16:43 Rev Time 0.00
Received By fmittner Date 2013-10-24 Time 16:43 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2013-08-28 Cont ID  
Sent By fmittner Date 2013-08-28 Time 13:51 Rev Time 0.00
Received By fmittner Date 2013-08-28 Time 13:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2014-07-23 Cont ID  
Sent By shill Date 2014-01-16 Time 15:07 Rev Time 0.00
Received By shill Date 2014-01-16 Time 19:39 Sent To  
Notes
2014-01-16 19:39:44SURVEY SUBMITTED
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-01-02 Cont ID  
Sent By skennedy Date 2014-01-02 Time 15:33 Rev Time 0.00
Received By skennedy Date 2014-01-02 Time 15:32 Sent To  
Notes
2014-01-02 15:34:43B, E, & I STOPS ENTERED IN ERROR, SEE 14010024.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-11-06 Cont ID  
Sent By jgomez Date 2013-11-06 Time 18:06 Rev Time 0.00
Received By jgomez Date 2013-10-18 Time 06:24 Sent To  
Notes
2013-10-21 13:54:32 
 10/21/13 SENT TO R7 SHELF FOR REVIEW. JG.
2013-10-19 06:26:05SENT TO J GOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-10-18 Cont ID  
Sent By shill Date 2013-10-16 Time 10:50 Rev Time 0.00
Received By rbrown Date 2013-08-28 Time 14:22 Sent To  
Notes
2013-08-28 14:26:39INCOMING SENT TO R18 . JW

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2013-10-23 Cont ID  
Sent By jgomez Date 2013-10-23 Time 18:13 Rev Time 0.00
Received By jgomez Date 2013-10-23 Time 18:13 Sent To  
Notes
2013-10-23 18:14:14NO FEES. MU-2013-22438. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2013-09-16 Cont ID  
Sent By jgomez Date 2013-09-16 Time 18:23 Rev Time 0.00
Received By jgomez Date 2013-09-16 Time 18:23 Sent To  
Notes
2013-09-16 18:23:312- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) TO VERIFY IF IMPACT FEES ARE
 REQUIRED. BRING BACK COUNTY STAMPED PLANS AND COPY OF
 PAID RECEIPT IF FEES ARE DUE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2013-10-24 Cont ID  
Sent By jgomez Date 2013-10-24 Time 16:20 Rev Time 0.00
Received By jgomez Date 2013-10-24 Time 16:20 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2013-09-18 Cont ID  
Sent By jgomez Date 2013-09-18 Time 08:35 Rev Time 0.00
Received By jgomez Date 2013-09-18 Time 08:34 Sent To  
Notes
2013-09-18 08:36:32RESIDENTIAL (R3) ADDITION, MECHANICAL REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- EQUIPMENT SIZING CALCULATIONS TO INCLUDE THE
 EQUIPMENT MANUFACTURER AND MODEL NUMBER. SEC. 403.6 OF
 2010 FBC-ENERGY CONSERVATION.
  
 2- EQUIPMENT INFORMATION TO BE INCLUDED IN THE A/C
 PLAN. SEC. 107.3.5.3(10) OF CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 3 Status P Date 2014-08-01 Cont ID  
Sent By shill Date 2014-08-01 Time 10:50 Rev Time 0.00
Received By shill Date 2014-08-01 Time 10:50 Sent To  
Notes
2014-08-01 10:50:29EC OK
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status F Date 2014-07-28 Cont ID  
Sent By shill Date 2014-07-28 Time 10:19 Rev Time 0.00
Received By shill Date 2014-07-28 Time 10:19 Sent To  
Notes
2014-07-28 10:27:07****CORRECTIONS****
 ****ELEVATION CERTIFICATE PREPARED BY ROBERT A BUGGEE
 DATED 4/10/14, "FINISHED CONSTRUCTION" ****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. SEE COMMENTS SECTION, PAGE 2. THE COMMENTS STATE (IN
 PART) "BUILDING UNDER CONSTRUCTION FINISHED FL
 ELEVATION: 7.70'. MECHANICAL EQUIPMENT NOT INSTALLED."
 MECHANICAL EQUIPMENT IS TO BE INSTALLED PRIOR TO FINAL
 EC.
  
 2. AS THIS EC NEEDS TO BE REVISED, PLEASE ALSO CORRECT
 ITEM B4, WHICH WSHOULD INCLUDE THE MAP NUMBER. THIS
 COMMENT WAS IN THE EC REVIEW PREVIOUSLY.
  
 3. AS THE EC COMMENTS SECTION NEEDS TO BE REVISED,
 PLEASE INCLUDE THE INFORMATION AS TO HOW THE LAT/LONG
 WAS DETERMINED AS PER EC INSTRUCTIONS.
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2014-07-23 Cont ID  
Sent By shill Date 2014-07-23 Time 14:55 Rev Time 0.00
Received By shill Date 2014-07-23 Time 14:55 Sent To  
Notes
2014-07-23 15:07:01****CORRECTIONS****
 ****ELEVATION CERTIFICATE PREPARED BY ROBERT A BUGGEE
 DATED 4/10/14, "FINISHED CONSTRUCTION" ****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. MECHANICAL EQUIPMENT IN SECTION C2 MUST BE 7.5'
 MINIMUM. NOTE THAT THIS IS TO BE THE ELEVATION OF THE
 MECHANICAL EQUIPMENT, NOT THE SLAB. IF STANDS ARE
 PROPOSED, THIS CAN BE EXPLAINED IN THE "COMMENTS"
 SECTION.
  
 THE MECHANICAL EQUIPMENT IS NOTED AS "NA" BUT THE
 "FINISHED CONSTRUCTION" IS NOT TO BE DONE UNTIL ALL
 EQUIPMENT IS INSTALLED. PHOTOGRAPHS SHOW AN ELEVATED
 (ON STAND) A/C UNIT.
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-09-18 Cont ID  
Sent By jgomez Date 2013-09-17 Time 18:45 Rev Time 0.00
Received By jgomez Date 2013-09-17 Time 18:36 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2013-10-24 Cont ID  
Sent By jgomez Date 2013-10-24 Time 10:25 Rev Time 0.00
Received By jgomez Date 2013-10-24 Time 10:25 Sent To  
Notes
2013-10-24 10:26:32FLAT ROOF FL16429 SUBMITTED. JG.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2013-09-17 Cont ID  
Sent By jgomez Date 2013-09-17 Time 18:35 Rev Time 0.00
Received By jgomez Date 2013-09-17 Time 18:35 Sent To  
Notes
2013-09-17 18:36:37NEED PRODUCT APPROVAL FOR FLAT ROOF AND RAS 117
 CALCULATIONS. JG.

Review Stop Z ZONING
Rev No 2 Status P Date 2013-10-24 Cont ID  
Sent By fmittner Date 2013-10-24 Time 16:44 Rev Time 0.00
Received By fmittner Date 2013-10-24 Time 16:44 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2013-08-28 Cont ID  
Sent By fmittner Date 2013-08-28 Time 13:51 Rev Time 0.00
Received By fmittner Date 2013-08-28 Time 13:51 Sent To  
Notes
***NONE***