| Plan Review Stops For Permit 13080942 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-05-20 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-05-20 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-05-20 |
Time |
07:07 |
Sent To |
Z |
|
| Notes |
| 2014-05-20 07:25:15 | PROVISIONALLY APPROVED SUBJECT TO THE FOLLOWING: | | | | | | PLEASE BE ADVISED THE INSPECTOR MAY REQUIRE PREVIOUSLY | | | COPLETED WORK TO BE MADE ACCESSIBLE AND OPEN FOR | | | INSPECTION OR REQUIRE ADDITIONAL DOCUMENTATION FOR ALL | | | CONCEALED WORK PREVIOUSLY COMPLETED PURSUANT TO FBC 110 | | | & FBC 117. | | | FBC 110.1 GENERAL. CONSTRUCTION OR WORK FOR WHICH A | | | PERMIT IS REQUIRED SHALL BE SUBJECT TO INSPECTION BY | | | THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR WORK | | | SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION | | | PURPOSES UNTIL APPROVED. | | | FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR | | | TEST REPORTS AS PROOF OF COMPLIANCE. REQUIRED TESTS ARE | | | TO BE MADE AT THE EXPENSE OF THE OWNER, OR AGENT, BY AN | | | APPROVED TESTING LABORATORY OR OTHER APPROVED AGENCY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-05-20 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2013-10-22 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2013-10-22 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2013-10-22 13:16:22 | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | 1) FBC 107.3.5.3 - PROVIDE SURVEY/SITE PLAN. | | | 2) FBC 107.3.4 - PROVIDE EVIDENCE OF REVIEW AND | | | APPROVAL IN WRITING OF THE SELECTED PRODUCT APPROVALS | | | BY THE DESIGNER OF RECORD, SPECIFICALLY FOR | | | WINDOWS/SLIDING GLASS DOOR. | | | | | | PLEASE BE ADVISED THE INSPECTOR MAY REQUIRE PREVIOUSLY | | | COPLETED WORK TO BE MADE ACCESSIBLE AND OPEN FOR | | | INSPECTION OR REQUIRE ADDITIONAL DOCUMENTATION FOR ALL | | | CONCEALED WORK PREVIOUSLY COMPLETED PURSUANT TO FBC 110 | | | & FBC 117. | | | FBC 110.1 GENERAL. CONSTRUCTION OR WORK FOR WHICH A | | | PERMIT IS REQUIRED SHALL BE SUBJECT TO INSPECTION BY | | | THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR WORK | | | SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION | | | PURPOSES UNTIL APPROVED. | | | FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR | | | TEST REPORTS AS PROOF OF COMPLIANCE. REQUIRED TESTS ARE | | | TO BE MADE AT THE EXPENSE OF THE OWNER, OR AGENT, BY AN | | | APPROVED TESTING LABORATORY OR OTHER APPROVED AGENCY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2013-10-16 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-10-16 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-10-16 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2013-10-16 13:31:37 | THIS FILE HAS BEEN APPROVED WITH THE HEREIN DESCRIBED | | | EXCEPTIONS WHICH SHALL BE BE REQUIRED FOR SUCCESSFUL | | | INSPECTIONS. | | | | | | FROM THE PERMIT APPLICATION, I GATHER THAT THIS | | | STRUCTURE WAS BUILT WITHOUT THE BENEFIT OF A PERMIT AND | | | OR INSPECTIONS SOME TIME AGO. REGARDLESS OF THE TIME IT | | | WAS BUILT, IT IS CURRENTLY BEING PERMITTED; THEREFORE | | | IT SHALL COMPLY WITH CURRENT CODE REQUIREMENTS AS | | | FOLLOWS: | | | 1. THE ADDITION OF THIS ROOM MANDATES COMPLIANCE WITH | | | THE FBCR 314. | | | 2. THE ELECTRICAL CIRCUITS WITHING THE AREA IN QUESTION | | | (WITHIN THE SCOPE OF THIS PERMIT) SHALL COMPLY WITH NEC | | | 210.12 (B) AFCI | | | 3. THE ELECTRICAL DEVICES WITH IN AREA IN QUESTION, | | | SHALL COMPLY WITH NEC 406.11 WHICH REQUIRES | | | TAMPER-RESISTANT OUTLETS. | | | 4. THE LIGHT ON THE EXTERIOR OF THE ENTRY DOOR SHALL | | | NOT BE BEHIND THE DOOR SWING. | | | 5. THE SUBMITTED DRAWING DOES NOT INDICATE COMPLIANCE | | | WITH NEC 210.52 WITH REGARDS TO PROPER OUTLET PLACING. | | | FURTHERMORE, THE DEDICATED OUTLET FOR THE WALL A/C UNIT | | | IS SHOWN TO BE 30 AMP AND THUS SHALL NOT BE CONSIDERED | | | AS PART OF THE REQUIRED OULTELS ALONG THE WALL LINE, | | | | | | THOUGH SOME OR ALL OF THE ABOVE MENTIONED REQUIREMENTS | | | MAY ALREADY BE IN PLACE, THEY ARE NOT REFLECTED ON THE | | | SUBMITTED DRAWING AND THUS MENTIONED HEREIN. | | | | | | SENT BACK TO BIN FOR FURTHER REVIEWS BY: MA | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-07-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-07-29 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-07-25 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2014-07-25 17:24:03 | RE-SUBMITTAL (SURVEYS) SENT TO ZONING SHELF FOR LINDA'S | | | REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-06-09 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-06-09 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-05-19 |
Time |
18:40 |
Sent To |
|
|
| Notes |
| 2014-05-19 18:44:55 | SENT TO S KENNEDY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-10-22 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2013-10-22 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2013-08-23 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2013-10-22 14:11:41 | LEFT VM WITH CONTACT. PLACED SUBMITTAL IN DENIED PLANS | | | SMALL "C." | | 2013-08-27 08:48:45 | SENT TO R28 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2014-08-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-08-18 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-08-18 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2014-08-18 16:13:06 | IMPACT FEES PAID. $180.65. MU-2014-018316. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2013-10-22 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2013-10-22 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2013-10-22 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2013-10-22 09:48:27 | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED. | | | THE PLANS ARE TO BE STAMPED AND RECEIPT PROVIDED. | | | CONTACT 561 233 5100. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2013-10-22 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2013-10-22 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2013-10-22 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2013-10-22 14:06:54 | PLEASE BE ADVISED THE INSPECTOR MAY REQUIRE PREVIOUSLY | | | COPLETED WORK TO BE MADE ACCESSIBLE AND OPEN FOR | | | INSPECTION OR REQUIRE ADDITIONAL DOCUMENTATION FOR ALL | | | CONCEALED WORK PREVIOUSLY COMPLETED PURSUANT TO FBC 110 | | | & FBC 117. | | | FBC 110.1 GENERAL. CONSTRUCTION OR WORK FOR WHICH A | | | PERMIT IS REQUIRED SHALL BE SUBJECT TO INSPECTION BY | | | THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR WORK | | | SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION | | | PURPOSES UNTIL APPROVED. | | | FBC 117 - THE BUILDING OFFICIAL (INSPECTOR) MAY REQUIRE | | | TESTS OR TEST REPORTS AS PROOF OF COMPLIANCE. REQUIRED | | | TESTS ARE TO BE MADE AT THE EXPENSE OF THE OWNER, OR | | | AGENT, BY AN APPROVED TESTING LABORATORY OR OTHER | | | APPROVED AGENCY. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2014-07-29 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2014-07-29 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2014-07-29 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2014-07-29 08:30:25 | ** ZONING PROVISO ** | | | | | | 1.) NO KITCHEN FACILITY PERMITTED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2014-05-20 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2014-05-20 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2014-05-20 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2014-05-20 14:50:46 | ** FAILED ** | | | | | | COMMENTS FROM 8/30/13 HAVE NOT BEEN ADDRESSED: | | | | | | 1.) PROVIDE AN UPDATED SURVEY OF THE PROPERTY. THE | | | SURVEY IS NEEDED TO DETERMINE THE SETBACKS OF THE | | | STRUCTURE, INCLUDING ALL PROJECTIONS (I.E. WALL MOUNTED | | | A/C UNIT) FROM THE PROPERTY LINES. | | | | | | PLEASE CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE | | | ARE QUESTIONS. | | | | | | | | | | | 2014-05-20 09:11:50 | 5/20/14 ZONING RECEIVED SENT TO L. SG |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-08-30 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2013-08-30 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2013-08-29 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2013-08-30 08:09:26 | FAILED. | | | | | | PROVIDE A SURVEY OF THE PROPERTY. | | | | | | PLEASE CONTACT LINDA LOUIE, PLANNER AT (561) 822-1442 | | | IF YOU HAVE ANY QUESTIONS. | | 2013-08-28 14:56:42 | 8/28/13 |
|
|