Plan Review Details - Permit 13080749
Plan Review Stops For Permit 13080749
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status N Date 2014-02-07 Cont ID  
Sent By jwitmer Date 2014-02-07 Time 10:34 Rev Time 0.00
Received By jwitmer Date 2014-02-07 Time 10:34 Sent To  
Notes
2014-02-07 10:34:38SUBMITTED FORM BOARD SURVEY. JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-11-22 Cont ID  
Sent By jwitmer Date 2013-11-22 Time 09:41 Rev Time 0.00
Received By jwitmer Date 2013-11-22 Time 05:57 Sent To  
Notes
2013-11-22 07:47:19BUILDING PLAN REVIEW
 PERMIT: 13080749
 ADD: 901 SOUTHERN BLVD
 CONT: MEHAFFEY CONSTRUCTION GROUP
 TEL: (561) 398-7600
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2ND REVIEW
 DATE: NOV. 22/ 2013
 ACTION BUILDING PROVISO:
  
 1-5) COMPLIED.
  
 6)BUILDING PROVISO:
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). A SEPERATE ROOFING
 PERMIT IS REQUIRED ADDITIONAL REVIEWS WITH ASSOCIATED
 FEES.
  
 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41
 COMPONENTS & CLADDING
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(D) ROOFING PRODUCTS AND ASSEMBLIES
 SUBMITTED:
 NOA 09-1027.07
 CARLISLE SURE-WELD SINGLE PLY TPO ROOF SYSTEMS OVER
 STEEL DECK
 EXPIRATION DATE 08/31/13 PERMIT APPLY DATE 8/20/2013
 NO SUB-SYSTEM WAS IDENTIFIED WILL REQUIRE ENHANCED
 FASTENING PER LIMITATION # 7 BY EITHER A ENGINEER OR
 ARCHITECT PER RAS 117.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
2013-11-22 06:49:38BUILDING PLAN REVIEW
 PERMIT: 13080749
 ADD: 901 SOUTHERN BLVD
 CONT: MEHAFFEY CONSTRUCTION GROUP
 TEL: (561) 398-7600
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 1ST REVIEW
 DATE: SEPT. 13/2013
 ACTION: DENIED
  
 1) WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER !, ADMINISTRATION, 2010 EDITION. MINIMUM
 PLAN REVIEW CRITERIA, COMMERCIAL BUILDING
 107.3.5.1.1 (1) SITE REQUIREMENTS
 PARKING
 VEHICLE LOADING
 ACCESS AISLE
 ACCESSIBLE ENTRANCE FROM THE STREET
 (2) SOILS REPORT
 (3) ENERGY CALCULATIONS
  
  
  
 2) SHEET LS2.1:
 2A) APPLICABLE CODES INDICATE THE 2007 FBC. MARCH 15/
 2012 STATEWIDE THE 2010 FBC WAS ADOPTED.
  
 2B) OCCUPANCY TYPE: MERCANTILE, SQUARE FOOT FOR DINING
 IS 956 SQ FT/ 15 SQ FT = 64 OCCUPANTS. 2010 FBC -B
 TABLE 1004.1.1. AREAS IN QUESTION ARE USUALLY 750 SQ FT
 FOR CONFERENCE ROOMS AND
 MERCANTILE AREAS SERVING FOOD WITH A DINING AREA OVER
 705 SQ FT, THESE AREAS ARE CONSIDED AN ASSEMBLY
 OCCUPANCY. TABLE 1004.1.1 THE ASSEMBLY OCCUPANCY IS A
 NET FIGURE THE REMOVAL OF WALLS, ACCESS AISLES MAY
 REDUCE THE AREA BELOW THE 750 SQ FT IN AREA.
  
 2C) THE KITACHEN OCCUPANCY IS TAKEN AT 100 SQ FT PLEASE
 SEE TABLE 1004.1.1. COMMERCIAL KITCHENS ARE TAKEN AT
 200 SQ FT PER OCCUPANT.
  
 2D) STORAGE AREAS ARE TAKEN AT 300 SQ FT, GROSS, TABLE
 1004.1.1.
  
 2E) IF THE OCCUPANT LOAD IS 50 OR MORE THAN 2 MEANS OF
 EGRESS WILL BE REQUIRED PER 2010 FBC-B TABLE 1015.1.
  
 3) SHEET A2.1 DOOR 105A IS LOCATED IN A CORRIDOR WITH A
 WIDTH OF 4'-4", THIS DOES NOT MEET THE REQUIREMENTS OF
 2010 FBC-B 1008.1.9.11. DURING ITS SWING, ANY DOOR IN A
 MEANS OF EGRESS SHALL LEAVE UNOBSTRUCTED AT LEAST ONE
 HALF OF THE REQUIRED WIDTH OF AN AISLE, CORRIDOR,
 PASSAGEWAY, OR LANDING, NOR PROJECT MORE THAN 7 INCHES
 (178 MM) INTO THE REQUIRED WIDTH OF AN AISLE, CORRIDOR,
 PASSAGEWAY OR LANDING, WHEN FULLY OPEN.
  
 4) S1.1 HAS ROOF PRESSURES FOR THE MWFRS MEMBERS BUT
 NOT FOR COMPONENTS AND CLADDING, PLEASE USE 10 SQ FT
 FOR FASTENERS AS WORE CASE FOR ZONES 1,2 & 3. 2010
 FBC-B 1609.6.4.4.1 COMPONENTS &CLADDING.
  
 5) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 6) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
 (C) STOREFRONT, CURTAINWALLS, WALL LOUVERS
 (D) ROOFING PRODUCTS AND ASSEMBLIES
 (E) SHUTTERS
 (F) SKYLIGHTS
 (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C
 STANDS
  
 7) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-09-14 Cont ID  
Sent By jwitmer Date 2013-09-14 Time 08:16 Rev Time 0.00
Received By jwitmer Date 2013-09-13 Time 14:51 Sent To  
Notes
2013-09-13 16:43:36BUILDING PLAN REVIEW
 PERMIT: 13080749
 ADD: 901 SOUTHERN BLVD
 CONT: MEHAFFEY CONSTRUCTION GROUP
 TEL: (561) 398-7600
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 1ST REVIEW
 DATE: SEPT. 13/2013
 ACTION: DENIED
  
 1) WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER !, ADMINISTRATION, 2010 EDITION. MINIMUM
 PLAN REVIEW CRITERIA, COMMERCIAL BUILDING
 107.3.5.1.1 (1) SITE REQUIREMENTS
 PARKING
 VEHICLE LOADING
 ACCESS AISLE
 ACCESSIBLE ENTRANCE FROM THE STREET
 (2) SOILS REPORT
 (3) ENERGY CALCULATIONS
  
  
  
 2) SHEET LS2.1:
 2A) APPLICABLE CODES INDICATE THE 2007 FBC. MARCH 15/
 2012 STATEWIDE THE 2010 FBC WAS ADOPTED.
  
 2B) OCCUPANCY TYPE: MERCANTILE, SQUARE FOOT FOR DINING
 IS 956 SQ FT/ 15 SQ FT = 64 OCCUPANTS. 2010 FBC -B
 TABLE 1004.1.1. AREAS IN QUESTION ARE USUALLY 750 SQ FT
 FOR CONFERENCE ROOMS AND
 MERCANTILE AREAS SERVING FOOD WITH A DINING AREA OVER
 705 SQ FT, THESE AREAS ARE CONSIDED AN ASSEMBLY
 OCCUPANCY. TABLE 1004.1.1 THE ASSEMBLY OCCUPANCY IS A
 NET FIGURE THE REMOVAL OF WALLS, ACCESS AISLES MAY
 REDUCE THE AREA BELOW THE 750 SQ FT IN AREA.
  
 2C) THE KITACHEN OCCUPANCY IS TAKEN AT 100 SQ FT PLEASE
 SEE TABLE 1004.1.1. COMMERCIAL KITCHENS ARE TAKEN AT
 200 SQ FT PER OCCUPANT.
  
 2D) STORAGE AREAS ARE TAKEN AT 300 SQ FT, GROSS, TABLE
 1004.1.1.
  
 2E) IF THE OCCUPANT LOAD IS 50 OR MORE THAN 2 MEANS OF
 EGRESS WILL BE REQUIRED PER 2010 FBC-B TABLE 1015.1.
  
 3) SHEET A2.1 DOOR 105A IS LOCATED IN A CORRIDOR WITH A
 WIDTH OF 4'-4", THIS DOES NOT MEET THE REQUIREMENTS OF
 2010 FBC-B 1008.1.9.11. DURING ITS SWING, ANY DOOR IN A
 MEANS OF EGRESS SHALL LEAVE UNOBSTRUCTED AT LEAST ONE
 HALF OF THE REQUIRED WIDTH OF AN AISLE, CORRIDOR,
 PASSAGEWAY, OR LANDING, NOR PROJECT MORE THAN 7 INCHES
 (178 MM) INTO THE REQUIRED WIDTH OF AN AISLE, CORRIDOR,
 PASSAGEWAY OR LANDING, WHEN FULLY OPEN.
  
 4) S1.1 HAS ROOF PRESSURES FOR THE MWFRS MEMBERS BUT
 NOT FOR COMPONENTS AND CLADDING, PLEASE USE 10 SQ FT
 FOR FASTENERS AS WORE CASE FOR ZONES 1,2 & 3. 2010
 FBC-B 1609.6.4.4.1 COMPONENTS &CLADDING.
  
 5) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 6) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
 (C) STOREFRONT, CURTAINWALLS, WALL LOUVERS
 (D) ROOFING PRODUCTS AND ASSEMBLIES
 (E) SHUTTERS
 (F) SKYLIGHTS
 (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C
 STANDS
  
 7) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-12-10 Cont ID  
Sent By albarran Date 2013-12-10 Time 19:31 Rev Time 0.00
Received By albarran Date 2013-12-10 Time 19:04 Sent To M
Notes
2013-12-10 19:32:42RETRURNED TO C19

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-09-25 Cont ID  
Sent By dharvey Date 2013-09-25 Time 15:44 Rev Time 0.00
Received By dharvey Date 2013-09-25 Time 15:44 Sent To  
Notes
2013-09-25 15:48:019-25-13
 1. PROVIDE CONCRETE POLE DETAIL AND ENGINEERED WIND
 LOAD CALCS TO MEET SOUTH FLORIDA CODES
 2. TIME CLOCK FOR EXTERIOR LIGHTING CONTROLS REQUIRED 5
 TO HAVE 10 HOUR BACK-UP PER FLORIDA ENERGY CODE SECTION
 505.2.4
 3. PLEASE NOTE THAT ALL KITCHEN RECEPTS ARE TO BE GFCI
 PROTECTED PER NEC 210.8.B
 4. PLEASE NOTE THAT CONDUIT SEALING IS NEEDED FOR
 ENTERING OR LEAVING WALKIN COOLERS AND FREEZERS PER NEC
 300.7
 VB

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2013-10-28 Cont ID  
Sent By shill Date 2013-10-28 Time 18:21 Rev Time 0.00
Received By shill Date 2013-10-28 Time 18:21 Sent To  
Notes
2013-10-28 18:22:05OK PER MANNY GONZALEZ - DEVELOPMENT PERMIT APPLIED FOR
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2013-12-02 Cont ID  
Sent By lphilmor Date 2013-12-02 Time 14:18 Rev Time 0.00
Received By lphilmor Date 2013-12-02 Time 14:18 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2013-08-23 Cont ID  
Sent By lphilmor Date 2013-08-23 Time 15:37 Rev Time 0.00
Received By lphilmor Date 2013-08-23 Time 15:37 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2013-11-21 Cont ID  
Sent By fmittner Date 2013-11-21 Time 15:05 Rev Time 0.00
Received By fmittner Date 2013-11-21 Time 15:05 Sent To  
Notes
2013-11-21 15:05:35PASSED WITH PROVISO/CLARIFICATION THAT HORIZONTAL
 BANDING IS NOT FOAM.
2013-11-13 14:56:3411/13/13

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2013-09-03 Cont ID  
Sent By fmittner Date 2013-09-03 Time 15:09 Rev Time 0.00
Received By fmittner Date 2013-09-03 Time 15:09 Sent To  
Notes
2013-09-03 15:14:19CLARIFY WINDOW FRAME COLOR AND CONFIRM CLEAR GLAZING
 QUESTIONS CONTACT FRIEDERIKE MITTNER 822-1457.
2013-09-03 15:11:56CLARIFICATION REQUIRED ON SHEET A4.1
 1B....PRE-ENGINEERED CANOPY. NEEDS TO BE FINISHED IN
 STUCCO AND CONSISTENT WITH 1A
 8' SITE WALL REQUIRED ON NORTH PROPERTY LINE AS PART OF
 APPROVAL, REWORK LOCATION OF OAKS AND HOLLY TO
 ACCOMODATE
 PLEASE NOTE SIGNAGE REQUIRES A SEPERATE PERMIT

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-02-07 Cont ID  
Sent By jwitmer Date 2014-02-07 Time 10:33 Rev Time 0.00
Received By jwitmer Date 2014-02-05 Time 17:05 Sent To  
Notes
2014-02-05 17:05:50SENT TO JW DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-12-12 Cont ID  
Sent By skennedy Date 2013-12-12 Time 11:32 Rev Time 0.00
Received By skennedy Date 2013-11-04 Time 12:11 Sent To  
Notes
2013-11-06 12:11:28C19

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-10-28 Cont ID  
Sent By shill Date 2013-10-28 Time 18:23 Rev Time 0.00
Received By shill Date 2013-08-20 Time 18:52 Sent To  
Notes
2013-08-21 18:52:55C09

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status N Date 2013-12-18 Cont ID  
Sent By jwitmer Date 2013-12-18 Time 11:03 Rev Time 0.00
Received By jwitmer Date 2013-12-18 Time 11:03 Sent To  
Notes
2013-12-18 11:05:25P. B. COUNTY IMPACT FEE ASSESSMENT:
 12/13/13
 1354 SQ FT
 FAST FOOD
 PLANS STAMPED NO FEES DUE. JW

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2013-11-22 Cont ID  
Sent By jwitmer Date 2013-11-22 Time 07:51 Rev Time 0.00
Received By jwitmer Date 2013-11-22 Time 07:51 Sent To  
Notes
2013-11-22 07:51:31BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2013-11-22 Cont ID  
Sent By jwitmer Date 2013-11-22 Time 07:50 Rev Time 0.00
Received By jwitmer Date 2013-11-22 Time 07:50 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2013-12-12 Cont ID  
Sent By skennedy Date 2013-12-12 Time 11:25 Rev Time 0.00
Received By skennedy Date 2013-12-12 Time 11:25 Sent To  
Notes
2013-12-10 19:34:20WAITING FOR YOU IN C19

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2013-10-02 Cont ID  
Sent By hmoser Date 2013-10-02 Time 10:39 Rev Time 0.00
Received By hmoser Date 2013-10-02 Time 09:49 Sent To  
Notes
2013-10-02 10:39:20PLANS DENIED
 1) PROVIDE CALCULATION OF HEATING AND COOLING LOADS.
 PER SECTION 503.2.1 FLORIDA ENERGY CODE 2010
 2) REFER TO SECTION 503.2.4.4 SHUT OFF DAMPER CONTROLS.
 2010 FLORIDA ENERGY CODE.
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2013-11-22 Cont ID  
Sent By jwitmer Date 2013-11-22 Time 09:42 Rev Time 0.00
Received By jwitmer Date 2013-11-22 Time 09:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2013-09-06 Cont ID  
Sent By lwagner Date 2013-09-06 Time 13:40 Rev Time 0.00
Received By lwagner Date 2013-09-05 Time 15:18 Sent To  
Notes
2013-09-06 13:40:41PLUMBING DRAWINGS ARE OK PENDING UPDATE REVISIONS ON
 ONE SET OF PLUMBING PLANS. ONE SET OF DRAWINGS SHOWS
 ADDITIONAL FLOOR DRAINS AND FILTERED WATER LINE AND THE
 OTHER SET DOES NOT.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status N Date 2013-11-22 Cont ID  
Sent By jwitmer Date 2013-11-22 Time 07:48 Rev Time 0.00
Received By jwitmer Date 2013-11-22 Time 07:48 Sent To  
Notes
2013-11-22 07:49:34BUILDING APPROVED WITH EXCEPTION!
  
 A SEPERATE PERMIT IS REQUIRED ADDITIONAL REVIEWS WITH
 ASSOCIATED FEES.
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S).
 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41
 COMPONENTS & CLADDING
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(D) ROOFING PRODUCTS AND ASSEMBLIES
 SUBMITTED:
 NOA 09-1027.07
 CARLISLE SURE-WELD SINGLE PLY TPO ROOF SYSTEMS OVER
 STEEL DECK
 EXPIRATION DATE 08/31/13 PERMIT APPLY DATE 8/20/2013
 NO SUB-SYSTEM WAS IDENTIFIED WILL REQUIRE ENHANCED
 FASTENING PER LIMITATION # 7 BY EITHER A ENGINEER OR
 ARCHITECT PER RAS 117.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2013-11-22 Cont ID  
Sent By jwitmer Date 2013-11-22 Time 07:47 Rev Time 0.00
Received By jwitmer Date 2013-11-22 Time 07:47 Sent To  
Notes
2013-11-22 07:48:19NO ROOFING PRODUCT APPROVALS WERE SUBMITTED.

Review Stop Z ZONING
Rev No 2 Status P Date 2013-11-21 Cont ID  
Sent By fmittner Date 2013-11-21 Time 15:05 Rev Time 0.00
Received By fmittner Date 2013-11-21 Time 15:05 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2013-09-03 Cont ID  
Sent By fmittner Date 2013-09-03 Time 15:12 Rev Time 0.00
Received By fmittner Date 2013-09-03 Time 15:12 Sent To  
Notes
2013-09-03 15:13:15SITE PLAN REQUIRES DIMENSIONS
 LANDSCAPE PLAN TO BE REVISED TO REFLECT 8' WALL AND
 OAK/HOLLY ADJUSTMENTS, HARDWOODS REQUIRE A ROOT BARRIER
 QUESTIONS CONTACT FRIEDERIKE MITTNER 822-1457
2013-08-28 14:45:498/28/13