| Plan Review Stops For Permit 13080706 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2014-01-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-01-09 |
Time |
07:00 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-01-09 |
Time |
06:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-11-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-11-20 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-11-20 |
Time |
07:32 |
Sent To |
|
|
| Notes |
| 2013-11-20 09:37:31 | BUILDING PLAN REVIEW | | | PERMIT: 13080706 | | | ADD: 2107 N DIXIE HWY | | | CONT: SERRAES CONSTRUCTION | | | TEL: (561)848-6607 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: WED NOV. 20/ 2013 | | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | | | 2) 2ND REQUEST, WHEN CALCULATING THE NUMBER OF | | | OCCUPANTS THAT USE THE INTERIOR CORRIDOR SEE 2010 FBC-B | | | TABLE 1004.1.1 THE OCCUPANT LOAD IS GREATER THAN 30 | | | WHICH REQUIRES A 1 HOUR RATED CORRIDOR (FBC-B TABLE | | | 1018.1). NEITHER LS-1 OR A-2 INDICATES THE USE OF FIRE | | | RATED CORRIDORS, THE 2010 FBC TABLE 1018.1 REQUIRES A 1 | | | HOUR FIRE RATED CORRIDOR IN A BUSINESS OCCUPANCY | | | NON-SPRINKLERED BUILDING WITH A OCCUPANT LOAD OF | | | GREATER THAN 30. BOTH THE 2007 FBC COMMENTARY AND BOAF | | | INTERPRETATION 4849 AGREE. | | | DATE: TUE JAN 9 2007 | | | REPORT #: 4849 | | | CODE: BUILDING | | | SECTION: 1016 | | | QUESTION: | | | IS IT THE INTENT OF FBC SECTION 1016.1 TO REQUIRE | | | 1-HOUR RATED EGRESS CORRIDORS IN A SINGLE TENANT | | | NON-SPRINKLERED BUSINESS OCCUPANCY ALTHOUGH THE FLORIDA | | | FIRE PREVENTION CODE 38.3.6 (2) PROVIDES AN | | | EXCEPTION FOR CORRIDORS IN A SPACE OCCUPIED BY A SINGLE | | | TENANT? | | | ANSWER: | | | YES, UNLESS THE EXCEPTION CAN BE MET TABLE 1016.1 | | | REQUIRES A GROUP B OCCUPANCY TO HAVE 1 HOUR RATINGS | | | FOR CORRIDORS SERVING OVER 30 IN AN UNSPRINKLED | | | BUILDING. | | | COMMENTARY: | | | IF A CONFLICT WITH THE FFPC DOES EXIST, THE STRICTER | | | REQUIREMENT GENERALLY PREVAILS. | | | | | | 3-5) COMPLIED. | | | | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-09-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-09-16 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-09-16 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2013-09-16 16:00:46 | BUILDING PLAN REVIEW | | | PERMIT: 13080706 | | | ADD: 2107 N DIXIE HWY | | | CONT: SERRAES CONSTRUCTION | | | TEL: (561)848-6607 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: SEPT 16/ 2013 | | | ACTION: DENIED | | | | | | 1) SHEET LS-1, UNDER THE HEADING NUMBER OF STORIES, THE | | | PLAN INDICATES THIS BUILDING IS A ONE STORY BUILDING 20 | | | FEET TALL? 107.2.1.3 WHAT IS ABOVE THIS SPACE, OR ARE | | | THE WALLS RUNNING ALL THE WAY TO THE ROOF? 107.2.1.3 | | | ADDITIONAL INFORMATION REQUIRED. | | | | | | 2) NEITHER LS-1 OR A-2 INDICATES THE USE OF FIRE RATED | | | CORRIDORS, THE 2010 FBC TABLE 1018.1 REQUIRES A 1 HOUR | | | FIRE RATED CORRIDOR IN A BUSINESS OCCUPANCY | | | NON-SPRINKLERED BUILDING WITH A OCCUPANT LOAD OF | | | GREATER THAN 30. BOTH THE 2007 FBC COMMENTARY AND BOAF | | | INTERPRETATION 4849 AGREE. | | | DATE: TUE JAN 9 2007 | | | REPORT #: 4849 | | | CODE: BUILDING | | | SECTION: 1016 | | | QUESTION: | | | IS IT THE INTENT OF FBC SECTION 1016.1 TO REQUIRE | | | 1?HOUR RATED EGRESS CORRIDORS IN A SINGLE TENANT | | | NON?SPRINKLERED BUSINESS OCCUPANCY ALTHOUGH THE FLORIDA | | | FIRE PREVENTION CODE 38.3.6 (2) PROVIDES AN | | | EXCEPTION FOR CORRIDORS IN A SPACE OCCUPIED BY A SINGLE | | | TENANT? | | | ANSWER: | | | YES, UNLESS THE EXCEPTION CAN BE MET TABLE 1016.1 | | | REQUIRES A GROUP B OCCUPANCY TO HAVE 1 HOUR RATINGS | | | FOR CORRIDORS SERVING OVER 30 IN AN UNSPRINKLED | | | BUILDING. | | | COMMENTARY: | | | IF A CONFLICT WITH THE FFPC DOES EXIST, THE STRICTER | | | REQUIREMENT GENERALLY PREVAILS. | | | | | | 3) NEITHER THE LS-1 OR A-2 SHOW FIRE RATED WALLS FOR | | | THE LAUNDRY, PLEASE REVIEW 2010 FBC-B TABLE 508.2.5 | | | LAUNDRIES 1 HOUR OR PROVIDE AN AUTOMATIC FIRE | | | SUPRESSION SYSTEM. | | | | | | 4) PRODUCT APPROVAL FOR A SWING DOOR ARE ALSO INCLUDED | | | IN THE PERMIT PACKAGE, SHEET A1 IS NOT CLEAR AS TO IF | | | ONLY THE SWING DOOR AND FRAME ARE BEING REPLACED OR IF | | | NEW OPENINGS ARE TO OCCUR. 107.2.1.3 ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 5) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2013-12-11 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2013-12-11 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2013-12-11 |
Time |
16:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-09-23 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-09-23 |
Time |
18:21 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-09-23 |
Time |
18:21 |
Sent To |
|
|
| Notes |
| 2013-09-23 18:24:06 | 9-23-13 | | | 1. ALL RECEPTACLES IN KITCHEN TO BE GFI PER NEC 210.8B. | | | THERE ARE NO EXCEPTIONS LISTED | | | | | | 2. FLUORESCENT FIXTURES REQUIRED INDIVIDUAL INTERNAL | | | DISCONNECTS PER NEC 410.130G | | | | | | 3. EXTERIOR LIGHTING MUST BE CONTROLLED PER FL ENERGY | | | CODE SECTION 505.2.4 | | | | | | VB |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2014-01-14 |
|
|
Cont ID |
|
| Sent By |
lphilmor |
Date |
2014-01-14 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
lphilmor |
Date |
2014-01-14 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2013-12-04 |
|
|
Cont ID |
|
| Sent By |
lphilmor |
Date |
2013-12-04 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
lphilmor |
Date |
2013-12-04 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2013-12-04 15:11:37 | PERMIT # 13080706 | | | PLAN REVIEW COMMENTS - FIRE DEPT | | | | | | | | | 1. A 1 HR SEPARATION WITH PROTECTED OPENINGS, DOORS, | | | AND DUCT WORK IS REQUIRED FOR HAZARD SEPARATION WHERE | | | STORAGE AREA AND SUPPLY STATION ARE LOCATED DUE TO | | | INCREASED COMBUSTIBLES BEING LOCATED IN THIS AREA. | | | 2. CORRIDOR SHOWS TYPE X DRYWALL. IS THIS INTENDED TO | | | BE A RATED COORIDOR? IF SO, PLEASE PROVIDE RATED | | | WINDOWS AND DOORS AND PENETRATIONS. - SEE BUILDING | | | COMMENTS | | | | | | | | | LAUREN PHILMORE | | | FIRE INSPECTOR II / INVESTIGATOR I | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4783 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2013-08-23 |
|
|
Cont ID |
|
| Sent By |
lphilmor |
Date |
2013-08-23 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
lphilmor |
Date |
2013-08-23 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2013-08-23 15:43:27 | 2107 N DIXIE HWY | | | PERMIT # 13080706 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | 1. A 1 HR SEPARATION WITH PROTECTED OPENINGS, DOORS, | | | AND DUCT WORK IS REQUIRED FOR HAZARD SEPARATION WHERE | | | STORAGE AREA, SUPPLY STATION, AND LAUNDRY ROOM ARE | | | LOCATED. | | | 2. CORRIDOR SHOWS TYPE X DRYWALL. IS THIS INTENDED TO | | | BE A RATED COORIDOR? IF SO, PLEASE PROVIDE RATED | | | WINDOWS AND DOORS AND PENETRATIONS. | | | 3. PROVIDE LOCATION OF PORTABLE FIRE EXTINGUISHERS | | | | | | | | | LAUREN PHILMORE | | | FIRE INSPECTOR II / INVESTIGATOR I | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 804-4783 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2013-09-13 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-09-13 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-09-12 |
Time |
13:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-01-21 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-01-21 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2013-12-20 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2013-12-23 14:28:22 | RESUBMITTAL SENT TO C5 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-12-11 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2013-12-11 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2013-10-31 |
Time |
17:34 |
Sent To |
|
|
| Notes |
| 2013-10-31 17:35:21 | INCOMING SENT TO C-01.JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-10-02 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-10-02 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-08-20 |
Time |
18:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2014-01-13 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-01-13 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-01-13 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2013-12-23 14:31:04 | NEW SHEET SUBMITTED. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2013-12-11 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2013-12-11 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2013-12-11 |
Time |
17:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2013-10-02 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-10-02 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-10-02 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2013-10-02 13:11:04 | PLANS DENIED | | | 1) REFER TO SECTION 602.2.1 MATERIALS WITHIN PLENUM'S | | | (CAN'T HAVE WOOD DOORS) 2010 FBC (M) | | | 2) REFER TO SECTION 503.2.1 CALCULATION OF HEATING AND | | | COOLING LOADS | | | FLORIDA ENERGY CODE. | | | 3) REFER TO SECTION 503.2.4.4 SHUTOFF DAMPER CONTROLS. | | | 2010 FLORIDA ENERGY CODE. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2013-09-13 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-09-13 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-09-12 |
Time |
11:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-09-11 |
|
|
Cont ID |
|
| Sent By |
avann |
Date |
2013-09-11 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2013-09-10 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2013-08-28 14:47:46 | 8/28/13 |
|
|