Plan Review Details - Permit 13080654
Plan Review Stops For Permit 13080654
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2013-09-14 Cont ID  
Sent By jwitmer Date 2013-09-14 Time 12:04 Rev Time 0.00
Received By jwitmer Date 2013-09-14 Time 12:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2014-02-04 Cont ID  
Sent By albarran Date 2014-02-04 Time 16:39 Rev Time 0.00
Received By albarran Date 2014-02-04 Time 16:39 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2014-01-06 Cont ID  
Sent By albarran Date 2014-01-06 Time 16:20 Rev Time 0.00
Received By albarran Date 2014-01-06 Time 16:19 Sent To I
Notes
2014-01-06 16:20:16VILLAS ON ANTIQUE ROW, BLDG. 5
 ELECTRICAL PLAN REVIEW NOTES FOR PERMITS: 13080647,
 13080648, 13080649, 13080650, 13080651, 13080653 AND
 13080654
  
 THE FOLLOWING NOTES ARE BASICALLY APPLICABLE TO ALL
 SEVEN (7) UNITS ALONG WITH THEIR SUBSEQUENT PERMIT
 NUMBERS AS DESCRIBED ABOVE:
 NOTE: THERE IS A CONFLICT IN THE UNIT DESIGNATIONS AS
 INDICATED ON THE ARCHITECTURAL DRAWINGS AND THE FIRE
 PROTECTION DRAWINGS.
  
 MOST OF THE ITEMS PREVIOUSLY ADDRESSED HAVE BEEN
 CORRECTED EXCEPT THE FOLLOWING:
  
 1. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE SIZED AS
 PER NEC 250.66 FOR FOUR (4) 350 KCMILS AL
 2. NOTE 2 ADDRESSING THE SMOKE/CARBON MONOXIDE
 DETECTORS IS INCORRECT. THE DEVICES ARE TO BE
 INTER-CONNECTED WITHIN THE UNIT, BUT AT NO TIME TIED IN
 TO THE FIRE ALARM SYSTEM. NONE OF THE NOTES MENTION THE
 INSTALLATION TO BE AS PER MANUFACTURER?S INSTRUCTIONS.
 (NOTE: THE USE OF COMBINATION SMOKE/CO DETECTORS AND
 FOLLOWING PROPER PLACEMENT MAY REDUCE THE NUMBER OF
 DEVICES REQUIRED FOR COMPLIANCE)
 3. AFTER LOOKING THROUGH THE ENTIRE SET, I FOUND THE
 REFERENCES TO THE EASEMENT ON PAGE 2.1 OF THE UNITS,
 BUT PAGE E1.1 FOR THE SKY END UNIT HAS YET TO BE
 CORRECTED.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-08-24 Cont ID  
Sent By dharvey Date 2013-08-24 Time 14:41 Rev Time 0.00
Received By dharvey Date 2013-08-24 Time 12:19 Sent To  
Notes
2013-08-24 14:41:011. ELECTRICAL OUTLET SPACING DOES NOT APPEAR TO FULLY
 MEET 210.52. RECEPTACLE SPACING TO MEET THE
 REQUIREMENTS OF THE NEC AT THE TIME OF INSTALLATION.
 ALL UNITS, ALL DESIGNS
 2. SMOKE/CO ALARMS ARE TO BE LOCATED PER MANUFACTURERS
 INSTRUCTIONS FOR BEST AND MOST EFFICIENT OPERATION FOR
 EARLY WARNING, NOT AS SHOWN ON THE PLANS. ALL UNITS,
 ALL DESIGNS
 3. PLEASE INCLUDE PROVISO NOTE FOR EASEMENTS AND THE
 REQUIREMENT FOR RECORDING OF UTILITY EASEMENTS:
 A. THE LOCATION OF UNDERGROUND ELECTRICAL SERVICES,
 FEEDERS, CIRCUITS, ?HOUSE? CIRCUITS, ALL CONDUITS, AND
 OTHER APPURTENANCES, ASSOCIATED WITH THE PREMISE SYSTEM
 AND INSTALLED AT THE TIME OF THE FORMBOARD SURVEY,
 SHALL BE SHOWN ON THE FORMBOARD SURVEY.
 B. UTILITY AND PREMISE EASEMENTS, EASEMENT LOCATIONS,
 AND ASSOCIATED RESTRICTIVE PROPERTY COVENANTS ARE TO BE
 SUBMITTED TO THE BUILDING OFFICIAL FOR REVIEW AND
 APPROVAL PRIOR TO RECORDING. SAID DOCUMENTS SHALL BE
 RECORDED AND PROOF OF RECORDING ON THE PLAT, AND
 ACCEPTANCE BY THE CITY SURVEYOR, SHALL BE PROVIDED
 PRIOR TO SCHEDULING OF ELECTRICAL ?ROUGH? INSPECTIONS.
 4. PROVIDE INTERSYSTEM BONDING POINT AT SERVICE PER
 250.94
 5. PLANS CALL FOR 2011 EDITION OF THE NEC. FLORIDA IS
 USING THE 2008 EDITION OF THE NEC AND ALL WORK IS TO
 COMPLY WITH THE ADOPTED STANDARDS AND REFERENCED
 DOCUMENTS IN ACCORDANCE WITH FLORIDA STATUTE 553.
 6. IDENTIFY UNITS AND SERVICES AT METERS AND
 DISCONNECTS. SERVICE MAINS DO NOT APPEAR TO AGREE WITH
 SERVICES AND CONDUCTOR SIZES.
 7. LOAD CALCULATION APPEARS TO BE MISSING. METER CENTER
 SHOWS A 200A AND ALL LOAD CALCULATIONS APPEAR TO BE FOR
 A 125 OR 150A SERVICE. PLEASE EXPLAIN, THIS DOES NOT
 APPEAR TO CORRESPOND WITH THE LOAD CALCULATION FOR THE
 BUILDING PROVIDED.
 8. ALL CONDUCTORS TO BE SIZED PER NEC 310.15. IF 90
 DEGREE C COLUMN IS TO BE USED, PROVIDE LISTING
 INFORMATION FOR ALL CONNECTIONS, CONDUIT AND OTHER
 PORTIONS OF THE ELECTRICAL SYSTEM TO ENSURE
 COMPATIBILITY. PLAN NOTES CALL FOR 75 DEGREE.
 9. DO SITE LIGHTING CONDUCTORS ACCOUNT FOR VOLTAGE
 DROP? FBC-EC 505.2
 10. NOTE 9 ON THE PLANS CALLS FOR TORQUEING OF ALUMINUM
 CONDUCTORS, NEC SECTION 110.13 CALLS FOR PROPER
 INSTALLATION OF ALL CONDUCTORS
 11. NOTE 10 CALLS FOR ANTI-OXIDANT AND WIRE BRUSHING OF
 AL CONDUCTORS. PLEASE PROVIDE MANUFACTURERS LISTING
 INFORMATION CALLING FOR THE PROPER APPLICATION AND
 MATERIALS. THIS MAY CONFLICT WITH NOTE 7.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-01-07 Cont ID  
Sent By shill Date 2014-01-07 Time 09:13 Rev Time 0.00
Received By shill Date 2013-11-21 Time 13:03 Sent To  
Notes
2014-01-06 16:20:55SH
2013-11-25 13:03:32C-28

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-10-02 Cont ID  
Sent By hmoser Date 2013-10-02 Time 08:29 Rev Time 0.00
Received By hmoser Date 2013-08-19 Time 15:02 Sent To  
Notes
2013-08-21 15:02:41INCOMING SENT TO C34. JW

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2014-02-12 Cont ID  
Sent By jwitmer Date 2014-02-12 Time 09:06 Rev Time 0.00
Received By jwitmer Date 2014-02-12 Time 09:06 Sent To  
Notes
2014-02-12 09:06:322/12/2014
 PLANS STAMPED FROM IMPACT FEES
 MU-2013-25245
 $17,080.70.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2013-09-14 Cont ID  
Sent By jwitmer Date 2013-09-14 Time 09:01 Rev Time 0.00
Received By jwitmer Date 2013-09-14 Time 08:41 Sent To  
Notes
2013-09-14 08:41:49BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2013-10-02 Cont ID  
Sent By hmoser Date 2013-10-02 Time 08:28 Rev Time 0.00
Received By hmoser Date 2013-10-01 Time 13:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2013-09-16 Cont ID  
Sent By lwagner Date 2013-09-16 Time 11:27 Rev Time 0.00
Received By lwagner Date 2013-09-09 Time 09:36 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2013-09-14 Cont ID  
Sent By jwitmer Date 2013-09-14 Time 09:00 Rev Time 0.00
Received By jwitmer Date 2013-09-14 Time 09:00 Sent To  
Notes
2013-09-14 09:00:20VILLAS ON ANTIQUE ROW
 ROOFING APPROVALS:
  
 SEE BLDG # 3 PRODUCT APPROVALS, PRODUCT APPROVALS FOR
 MASTER FOR BUILDINGS 3-7.
  
 ENTEGRA ROOF TILE
 ESTATE "S" TILE
 NOA 11-0510.02
 2-10D RING SHANK NAILS 37.4 MOMENT
  
 BORAL TILE SEAL
 NOA 12-1219.01
  
 O"HAGIN CLOAKED VENT TILE
 NOA 09-0316.04

Review Stop Z ZONING
Rev No 2 Status P Date 2014-01-07 Cont ID  
Sent By dmalone Date 2014-01-07 Time 09:13 Rev Time 0.00
Received By shill Date 2014-01-07 Time 09:13 Sent To  
Notes
2014-01-07 09:15:07OK PER D MALONE
 SEE REVIEW UNDER 13080647
 CO IS CONTINGENT UPON AND LINKED TO LDSPE PERMIT
 13080663 (PHASE V) APPROVED WITH CONDITIONAL APPROVAL
 REQUIRING PASSING FINAL LDSPE AND IRRIGATION
 INSPECTIONS.
  
  
2013-12-02 12:08:4612/2/13

Review Stop Z ZONING
Rev No 1 Status F Date 2013-10-12 Cont ID  
Sent By dmalone Date 2013-10-12 Time 11:21 Rev Time  
Received By rmcdouga Date   Time   Sent To  
Notes
2013-10-12 11:21:56SEE NOTES FOR 13080656
2013-08-28 14:40:328/28/13


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved