| Plan Review Stops For Permit 13080650 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2013-09-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-09-14 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-09-14 |
Time |
08;00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2014-02-04 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-02-04 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-02-04 |
Time |
16:37 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-01-06 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2014-01-06 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2014-01-06 |
Time |
16:16 |
Sent To |
I |
|
| Notes |
| 2014-01-06 16:16:36 | VILLAS ON ANTIQUE ROW, BLDG. 5 | | | ELECTRICAL PLAN REVIEW NOTES FOR PERMITS: 13080647, | | | 13080648, 13080649, 13080650, 13080651, 13080653 AND | | | 13080654 | | | | | | THE FOLLOWING NOTES ARE BASICALLY APPLICABLE TO ALL | | | SEVEN (7) UNITS ALONG WITH THEIR SUBSEQUENT PERMIT | | | NUMBERS AS DESCRIBED ABOVE: | | | NOTE: THERE IS A CONFLICT IN THE UNIT DESIGNATIONS AS | | | INDICATED ON THE ARCHITECTURAL DRAWINGS AND THE FIRE | | | PROTECTION DRAWINGS. | | | MOST OF THE ITEMS PREVIOUSLY ADDRESSED HAVE BEEN | | | CORRECTED EXCEPT THE FOLLOWING: | | | | | | 1. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE SIZED AS | | | PER NEC 250.66 FOR FOUR (4) 350 KCMILS AL | | | 2. NOTE 2 ADDRESSING THE SMOKE/CARBON MONOXIDE | | | DETECTORS IS INCORRECT. THE DEVICES ARE TO BE | | | INTER-CONNECTED WITHIN THE UNIT, BUT AT NO TIME TIED IN | | | TO THE FIRE ALARM SYSTEM. NONE OF THE NOTES MENTION THE | | | INSTALLATION TO BE AS PER MANUFACTURER?S INSTRUCTIONS. | | | (NOTE: THE USE OF COMBINATION SMOKE/CO DETECTORS AND | | | FOLLOWING PROPER PLACEMENT MAY REDUCE THE NUMBER OF | | | DEVICES REQUIRED FOR COMPLIANCE) | | | 3. AFTER LOOKING THROUGH THE ENTIRE SET, I FOUND THE | | | REFERENCES TO THE EASEMENT ON PAGE 2.1 OF THE UNITS, | | | BUT PAGE E1.1 FOR THE SKY END UNIT HAS YET TO BE | | | CORRECTED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-09-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-08-24 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-09-17 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2013-09-17 08:14:05 | SEE REVIEW BY DOUG HARVEY 13080654 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-01-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-01-07 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-11-25 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2014-01-06 16:16:58 | SH | | 2013-11-25 12:57:39 | C-28 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-10-02 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-10-02 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-08-19 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2013-08-21 14:59:57 | INCOMING SENT TO C34. JW |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2014-02-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-02-12 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-02-12 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2014-02-12 09:03:19 | 2/12/2014 | | | PLANS STAMPED FROM IMPACT FEES | | | MU-2013-25245 | | | $17,080.70. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2013-09-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-09-14 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-09-14 |
Time |
08:39 |
Sent To |
|
|
| Notes |
| 2013-09-14 08:39:39 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2013-10-02 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2013-10-02 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2013-10-02 |
Time |
08:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2013-09-16 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-09-16 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-09-09 |
Time |
09:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2013-09-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2013-09-14 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2013-09-14 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2013-09-14 08:57:35 | VILLAS ON ANTIQUE ROW | | | ROOFING APPROVALS: | | | | | | SEE BLDG # 3 PRODUCT APPROVALS, PRODUCT APPROVALS FOR | | | MASTER FOR BUILDINGS 3-7. | | | | | | ENTEGRA ROOF TILE | | | ESTATE "S" TILE | | | NOA 11-0510.02 | | | 2-10D RING SHANK NAILS 37.4 MOMENT | | | | | | BORAL TILE SEAL | | | NOA 12-1219.01 | | | | | | O"HAGIN CLOAKED VENT TILE | | | NOA 09-0316.04 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2014-01-07 |
|
|
Cont ID |
|
| Sent By |
dmalone |
Date |
2014-01-07 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-01-07 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2014-01-07 09:10:48 | OK PER D MALONE | | | SEE REVIEW UNDER 13080647 | | | CO IS CONTINGENT UPON AND LINKED TO LDSPE PERMIT | | | 13080663 (PHASE V) APPROVED WITH CONDITIONAL APPROVAL | | | REQUIRING PASSING FINAL LDSPE AND IRRIGATION | | | INSPECTIONS. | | | | | | | | 2013-12-02 12:24:29 | 12/2/13 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2014-02-12 |
|
|
Cont ID |
|
| Sent By |
dmalone |
Date |
2014-02-12 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-02-12 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2013-08-28 14:43:12 | 8/28/13 |
|
|