Plan Review Details - Permit 13080645
Plan Review Stops For Permit 13080645
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2013-09-14 Cont ID  
Sent By shill Date 2013-09-14 Time 12:44 Rev Time 0.00
Received By shill Date 2013-09-14 Time 12:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2013-09-03 Cont ID  
Sent By shill Date 2013-09-03 Time 10:13 Rev Time 0.00
Received By shill Date 2013-09-03 Time 10:13 Sent To  
Notes
2013-09-03 10:21:42***CORRECTIONS***
  
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 FROM PREVIOUS LIST:
  
 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE
 ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER
 FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED.
 THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET
 AT
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
 2ND REVIEW, SUBMITTED BUT NOT ALL COLUMNS WERE
 COMPLETED. PLEASE COMPLETE THE FOLLOWING COLUMNS: WALL
 PRESSURE, SHUTTER GLASS SEPARATION, SPAN (THIS IS BLADE
 LENGTH OR ANCHOR TO ANCHOR, SHOULD BE ONE DIMENSION,
 NOT TWO), AND EDGE DISTANCE.
  
 SHUTTER CONNECTION MOUNTING TYPE SHOULD CORRELATE WITH
 ANCHOR CHART, SEE SHEET 7 (CONNECTION TYPES ARE NAMED 1
 THROUGH 8).
  
 2. PROVIDE THE COVER SHEET FOR THE FLORIDA STATE
 PRODUCT APPROVAL, FAC9N-3. THIS IS AVAILABLE AT
 WWW.FLORIDABUILDING.ORG. THIS WILL INCLUDE THE APPROVAL
 NUMBER AND THE STATUS, WHICH SHOULD BE "APPROVED."
  
 NOT ADDRESSED
  
 3. TWO DIFFERENT EVALUATION REPORTS PROVIDED. THE
 INSTALLATION SCHEDULE OR A REVISED FLOOR PLAN SHOULD
 INDICATE WHICH OF THE PRODUCTS IS PROPOSED IN EACH
 LOCATION.
  
 NOT ADDRESSED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-08-21 Cont ID  
Sent By shill Date 2013-08-20 Time 18:38 Rev Time 0.00
Received By shill Date 2013-08-20 Time 18:38 Sent To  
Notes
2013-08-20 18:39:10***CORRECTIONS***
  
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
  
 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE
 ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER
 FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED.
 THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET
 AT
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
 2. PROVIDE THE COVER SHEET FOR THE FLORIDA STATE
 PRODUCT APPROVAL, FAC9N-3. THIS IS AVAILABLE AT
 WWW.FLORIDABUILDING.ORG. THIS WILL INCLUDE THE APPROVAL
 NUMBER AND THE STATUS, WHICH SHOULD BE "APPROVED."
  
 3. TWO DIFFERENT EVALUATION REPORTS PROVIDED. THE
 INSTALLATION SCHEDULE OR A REVISED FLOOR PLAN SHOULD
 INDICATE WHICH OF THE PRODUCTS IS PROPOSED IN EACH
 LOCATION.
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-09-14 Cont ID  
Sent By shill Date 2013-09-14 Time 12:44 Rev Time 0.00
Received By shill Date 2013-09-06 Time 11:29 Sent To  
Notes
2013-09-06 11:29:17TO SH DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-09-03 Cont ID  
Sent By shill Date 2013-09-03 Time 10:21 Rev Time 0.00
Received By shill Date 2013-08-26 Time 17:21 Sent To  
Notes
2013-08-26 17:22:03SENT TO S HILL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-08-20 Cont ID  
Sent By shill Date 2013-08-20 Time 18:39 Rev Time 0.00
Received By shill Date 2013-08-19 Time 13:22 Sent To  
Notes
2013-08-19 13:22:38ROUTED TO BLDG LESS THAN 5000