Plan Review Details - Permit 13080612
| Plan Review Stops For Permit 13080612 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-02-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-02-04 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-02-04 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2014-02-04 08:48:46 | BUILDING REVIEW APPROVED WITH PROVISO. SEE COMMENTS ON | | | PACKAGE SUBMITTED. JG. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-08-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-08-27 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-08-27 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2013-08-27 17:10:22 | RESIDENTIAL (R3) REVISIONS, BUILDING REVIEW COMMENTS. | | | CODE; 2010 FBC. | | | | | | 1- VALUATION NEEDS TO BE UPDATED TO INCLUDE ALL THE | | | WORK TO BE DONE. VALUATION TO INCLUDE ALL LABOR, | | | MATERIALS AND CONTRACTOR'S OVERHEAD AND PROFIT. SEC. | | | 109.3 CITY AMENDMENTS TO FBC. | | | | | | 2- NO CENTRAL A/C AND HEATING IS PROVIDED NOW. NEED TO | | | PROVIDE HEAT AS REQUIRED BY SEC. R303.8 OF 2010 | | | FBC-RESIDENTIAL. PROVIDE A/C UNIT MANUFACTURER | | | SPECIFICATIONS TO VERIFY THAT HEATING IS PROVIDED. | | | ***NOTE: DEDICATED 220 OUTLETS MAY BE REQUIRED FOR EACH | | | UNIT. CHECK THE ELECTRICAL PLAN REVIEW COMMENTS. | | | | | | 3- SIZE OF ROOMS WERE CHANGED. PROVIDE PLANS WITH | | | DIMENSIONS TO VERIFY COMPLIANCE WITH SEC. R304 OF 2010 | | | FBC-RESIDENTIAL. | | | | | | 4- PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS | | | SHOWING HOW ENCLOSING THE OPENINGS WERE EXTERIOR DOORS | | | ARE REMOVED. SEC. 107.2.1 CITY AMENDMENTS TO FBC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-02-12 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-02-12 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-02-12 |
Time |
11:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-09-16 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-09-16 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-09-16 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2013-09-16 16:35:47 | FIRST REVIEW 9-16-13 | | | | | | 1. PLEASE PROVIDE A PROFESSIONAL ELECTRICAL DRAWING | | | INCLUDING ALL THE FOLLOWING........ | | | | | | A. SHOW CIRCUITS AND PANEL ON FLOOR PLAN FOR CLARITY | | | AMD REFERENCE | | | B. SMOKE ALARMS FOR EACH SEPERATE UNIT WITHOUT TYING | | | THE TWO TOGETHER. | | | C. IF WATER HEATERS ARE REPLACED, THEY MUST BE | | | HARDWIRED WITH A DISCONNECT | | | D. PROVIDE DEDICAYTED CIRCUITS FOR ALL AC UNITS | | | VB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-02-12 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-02-12 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-01-22 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2014-01-23 09:29:55 | R07 | | | TRAVELLING WITH REVISION #13080613 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-09-16 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-09-16 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-09-16 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2013-08-27 14:41:01 | REVISION SENT TO R2 SHELF FOR REVIEW. JG. | | 2013-08-22 10:36:08 | TO JG DESK | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-02-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-02-04 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-02-04 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2014-02-04 10:02:34 | APPROVED WITH PROVISO; VERIFY ACCESS DOOR LOCATION FOR | | | WATER HEATER. JG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2013-08-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2013-08-27 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2013-08-27 |
Time |
17:44 |
Sent To |
|
|
| Notes |
| 2013-08-27 17:45:10 | RESIDENTIAL (R3) REVISION, PLUMBING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1-ACCESSS TO WATER HEATER DOESN'T COMPLY WITH SEC. | | | P2801.3 AND SEC. M1305.1. REMOVING OTHER APPLIANCES IS | | | NOT ALLOWED TO HAVE ACCES TO THE WATER HEATER. | | | | | | 2- PROVIDE CLEAR AND CORRECT PLUMBING RISER DIAGRAM | | | THAT MATCHES FLOOR PLAN. SEC. 107.3.5.3(11) OF CITY | | | AMENDMENTS TO FBC. | | | ***NOTE: LICENSED PLUMBER DOING THE JOB MAY DRAW THE | | | PLUMBING RISER. THIS WILL EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712. |
|
|
|