Plan Review Details - Permit 13080586
Plan Review Stops For Permit 13080586
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2013-10-26 Cont ID  
Sent By shill Date 2013-10-26 Time 16:18 Rev Time 0.00
Received By shill Date 2013-10-19 Time 11:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2013-09-23 Cont ID  
Sent By shill Date 2013-09-23 Time 17:57 Rev Time 0.00
Received By shill Date 2013-09-23 Time 17:57 Sent To  
Notes
2013-09-23 18:00:44****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
 [email protected]
  
 1. FBC 2010 RESIDENTIAL:
  
 SPANS NOT CORRECT, AND THEREFORE CANNOT DETERMINE
 WHETHER OR NOT ANCHOR SPACING OF 10" COMPLIES.
  
 FOR INSTANCE - OPENING 1, 47 X 86, SPAN IS SHOWN AS 4',
 VERTICAL INSTALLATION. 86" PLUS EDGE DISTANCE (1 1/2"
 TOP AND BOTTOM) SHOULD BE 89" SPAN. 8' SPAN, PANELMATE,
 60PSF (SEE PRODUCT APPROVAL) APPEARS TO REQUIRE 5"
 SPACING (PRODUCT APPROVAL SUBMITTED IS DIFFICULT TO
 READ).
  
 SPAN SHOULD BE THE DIMENSION OF ANCHOR TO ANCHOR.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2013-09-11 Cont ID  
Sent By shill Date 2013-09-11 Time 19:08 Rev Time 0.00
Received By shill Date 2013-09-11 Time 19:08 Sent To  
Notes
2013-09-11 19:09:25****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
  
 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE
 ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER
 FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED.
 THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET
 AT
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
 COMPLIANCE CANNOT BE DETERMINED WITHOUT INFORMATION
 SUCH AS SUBSTRATE. IT WOULD BE HELPFUL (BUT NOT
 REQUIRED) IF THE SPECIFIC PROPOSED ANCHOR SPACING ON
 THE CHART FROM THE PRODUCT APPROVAL IS CIRCLED AND
 SUBMITTED.
  
 PLEASE NOTE THAT FOR HORIZONTAL INSTALLATION, SUBSTRATE
 IS USUALLY FILLED CMU OR HOLLOW CMU, NOT CONCRETE.
  
 2ND REVIEW - SAME PAPERWORK SUBMITTED. PLEASE SEE
 SAMPLE FORM. THE CHART THAT WAS SUBMITTED LACKS
 INFORMATION SUCH AS CONNECTION MOUNTING TYPE, EDGE
 DISTANCE. PLEASE SEE THE FORM AT THE LINK PROVIDED
 ABOVE OR IN THE LOBBY.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-08-27 Cont ID  
Sent By shill Date 2013-08-27 Time 17:12 Rev Time 0.00
Received By shill Date 2013-08-27 Time 17:12 Sent To  
Notes
2013-08-27 17:14:19****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
  
 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE
 ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER
 FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED.
 THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET
 AT
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
 COMPLIANCE CANNOT BE DETERMINED WITHOUT INFORMATION
 SUCH AS SUBSTRATE. IT WOULD BE HELPFUL (BUT NOT
 REQUIRED) IF THE SPECIFIC PROPOSED ANCHOR SPACING ON
 THE CHART FROM THE PRODUCT APPROVAL IS CIRCLED AND
 SUBMITTED.
  
 PLEASE NOTE THAT FOR HORIZONTAL INSTALLATION, SUBSTRATE
 IS USUALLY FILLED CMU OR HOLLOW CMU, NOT CONCRETE.
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2013-10-26 Cont ID  
Sent By shill Date 2013-10-26 Time 16:18 Rev Time 0.00
Received By shill Date 2013-10-04 Time 06:31 Sent To  
Notes
2013-10-05 06:32:07SENT TO S HILL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-09-23 Cont ID  
Sent By shill Date 2013-09-23 Time 18:00 Rev Time 0.00
Received By shill Date 2013-09-16 Time 11:23 Sent To  
Notes
2013-09-16 11:24:03TO SH DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-09-11 Cont ID  
Sent By shill Date 2013-09-11 Time 19:09 Rev Time 0.00
Received By shill Date 2013-08-31 Time 12:05 Sent To  
Notes
2013-08-31 12:06:01TO SH DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-08-27 Cont ID  
Sent By shill Date 2013-08-27 Time 17:14 Rev Time 0.00
Received By shill Date 2013-08-16 Time 16:53 Sent To  
Notes
2013-08-16 16:53:43INCOMING SENT TO SAMANTHAS' DESK. JW