Plan Review Details - Permit 13080515
| Plan Review Stops For Permit 13080515 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2013-10-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-10-26 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-10-26 |
Time |
09:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2013-10-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-10-21 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-10-21 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2013-10-21 08:02:48 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FROM PREVIOUS LIST: | | | | | | FBC 2010 EXISTING BUILDING CODE, CHAPTER 10 ADDITIONS: | | | | | | 1. REVISE PLAN TO SHOW THE AREA OF THE EXISTING | | | BUILDING, BUILDING TYPE (FBC CHAPTER 6), AND OCCUPANCY | | | CLASSIFICATION (FBC CHAPTER 3). | | | | | | 2ND REVIEW - | | | | | | EXISTING BUILDING IS SHOWN AS TYPE IV, SPRINKLERED. | | | TYPE IV IS HEAVY TIMBER - AERIALS SHOW THIS AS A | | | QUONSET HUT, WHICH IS TYPICALLY STEEL. PLEASE PROVIDE | | | INFORMATION TO SHOW HOW IT HAS BEEN DETERMINED THAT | | | THIS IS A HEAVY TIMBER BUILDING. | | | | | | 2. REVISE PLAN TO SHOW THE BUILDING TYPE OF THE | | | PROPOSED NEW STRUCTURE (FBC CHAPTER 6). | | | | | | TYPE IIB IS SHOWN AS PROPOSED NEW CONSTRUCTION. FOAM IS | | | NOT TYPICALLY CONSIDERED NON COMBUSTIBLE. PROVIDE DATA | | | TO SHOW THAT THE FOAM PANELS ARE NON COMBUSTIBLE. | | | | | | 3. REVISE PLAN TO SHOW COMPLIANCE WITH FBC TABLE 601, | | | BUILDING HEIGHT AND AREA (EXISTING BUILDING PLUS | | | ADDITION). | | | | | | BUILDING IS NOTED AS SPRINKLERED, BUT IF SPRINKLERS ARE | | | REQUIRED FOR THIS BUILDING TO COMPLY WITH FBC TABLE | | | 503, SPRINKLERS WOULD BE REQUIRED FOR THE ADDITION. | | | | | | **NEW COMMENT** | | | | | | 4. PLEASE SEE FBC TABLE 503 AND 601. IT APPEARS THAT | | | THE EXISTING STRUCTURE AND THE PROPOSED ADDITION MAY BE | | | TYPE VB CONSTRUCTION. SEE FBC 506.2, AREA INCREASES MAY | | | APPLY. PLEASE REVISE PLANS TO SHOW COMPLIANCE WITH | | | ABOVE CITED CODE SECTIONS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-09-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-09-06 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-09-06 |
Time |
09:07 |
Sent To |
FIRE |
|
| Notes |
| 2013-09-06 09:11:48 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC 2010 EXISTING BUILDING CODE, CHAPTER 10 ADDITIONS: | | | | | | 1. REVISE PLAN TO SHOW THE AREA OF THE EXISTING | | | BUILDING, BUILDING TYPE (FBC CHAPTER 6), AND OCCUPANCY | | | CLASSIFICATION (FBC CHAPTER 3). | | | | | | 2. REVISE PLAN TO SHOW THE BUILDING TYPE OF THE | | | PROPOSED NEW STRUCTURE (FBC CHAPTER 6). | | | | | | 3. REVISE PLAN TO SHOW COMPLIANCE WITH FBC TABLE 601, | | | BUILDING HEIGHT AND AREA (EXISTING BUILDING PLUS | | | ADDITION). | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
N |
Date |
2013-09-12 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2013-09-12 |
Time |
17:58 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2013-09-12 |
Time |
17:58 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2013-10-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-10-26 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-10-26 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2013-10-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-10-21 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-10-07 |
Time |
17:08 |
Sent To |
|
|
| Notes |
| 2013-10-09 17:09:30 | SENT TO S HILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-09-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-09-12 |
Time |
18:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-08-14 |
Time |
18:05 |
Sent To |
|
|
| Notes |
| 2013-08-14 18:05:34 | TO ZONING | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2013-09-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-09-06 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-09-06 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2013-09-06 09:12:13 | NOT HABITABLE SPACE | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-08-16 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2013-08-16 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2013-08-16 |
Time |
15:11 |
Sent To |
B |
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |