Plan Review Details - Permit 13080476
| Plan Review Stops For Permit 13080476 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-08-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-08-21 |
Time |
07:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-08-21 |
Time |
07:27 |
Sent To |
|
|
| Notes |
| 2013-08-21 07:31:10 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. FBC 1609, SPECIFICATION FOR FASTENING CANNOT BE "AS | | | NEEDED." GRAPHICALLY THREE FASTENERS TOP AND BOTTOM ARE | | | SHOWN FOR A 30' SPAN. IF PLANS ARE NOT PREPARED BY A | | | DESIGN PROFESSIONAL, PROVIDE CALCULATIONS TO SHOW HOW | | | THIS WILL RESIST WIND LOADS. | | | | | | 2. REVISE PLAN TO INCLUDE WIND DESIGN CRITIERA FBC | | | 1603.4.1. | | | | | | 3. IF PLANS ARE PREPARED BY A DESIGN PROFESSIONAL | | | (ARCHITECT OR ENGINEER), TITLE BLOCK REQUIRED FS | | | 471,481. IF PLANS ARE PREPARED BY SOMEONE OTHER THAN A | | | DESIGN PROFESSIONAL, THE PLANS WILL INCLUDE THE PRINTED | | | NAME AND SIGNATURE OF THE INDIVIDUAL TAKING | | | RESPONSIBILITY FOR THE DESIGN FBC 107. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2013-08-15 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-08-15 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-08-15 |
Time |
18:41 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-08-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-08-21 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-08-13 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2013-08-13 16:43:20 | ROUTED TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2013-08-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-08-21 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-08-15 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2013-08-21 07:32:02 | 8/21 OK PER LINDA LOUIE (SEE SIGNATURE ON PLAN AND PLAN | | | REVIEW NOTE, NO OUT STOP OR STATUS ENTERED) | | | | | | | | 2013-08-15 10:59:58 | ZONING APPROVED FOR A TEMPORARY SIGN. |
|
|
|