Plan Review Details - Permit 13080444
| Plan Review Stops For Permit 13080444 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2013-09-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2013-09-05 |
Time |
19:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2013-09-05 |
Time |
19:15 |
Sent To |
E |
|
| Notes |
| 2013-09-05 19:17:43 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. PLAN TO INCLUDE WIND DESIGN CRITERIA FBC 2010 1609. | | | | | | 2. PLANS ARE TO BE PREPARED BY A DESIGN PROFESSIONAL, | | | FS 471. | | | | | | 3. PROVIDE A COPY OF THE CONTRACT FOR THIS JOB FBC 109. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2013-09-10 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2013-09-10 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2013-09-10 |
Time |
16:02 |
Sent To |
P |
|
| Notes |
| 2013-09-10 16:08:45 | PROVIDE ELECTRICAL PERMIT | | | PROVIDE DRAWINGS SHOWING PUMP INFORMATION AND ELECTRIC | | | SOURCE ALONG WITH PROTECTION AND LOCATION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2013-09-11 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-09-11 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-08-13 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2013-09-05 19:18:18 | 9/5 TO ELEC | | | | | 2013-08-14 14:12:18 | SENT TO ZONING SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2013-09-11 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2013-09-11 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2013-09-11 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2013-09-11 11:14:08 | WILL BE OK PENDING COMPLIANCE WITH ZONING COMMENTS | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2013-08-16 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2013-08-16 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2013-08-15 |
Time |
09:37 |
Sent To |
B |
|
| Notes |
| 2013-08-16 10:14:26 | ZONING FAILED FOR THE FOLLOWING REASON: | | | | | | 1.) THE PROPOSED 7 FT. HIGH WATERFALL DOES NOT MEET THE | | | DISTRICT SETBACK REQUIREMENTS FOR A STRUCTURE ABUTTING | | | A RESIDENTIAL ZONING DISTRICT. THE WATERFALL STRUCTURE | | | MUST BE SETBACK AT LEAST 15 FT. FROM THE REAR PROPERTY | | | LINE (ZLDR S. 94-144(2)(D). THE PLANS SHOWS THE | | | PROPOSED WATERFALL STRUCTURE SETBACK 2 FT. FROM THE | | | REAR PROPERTY LINE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | LINDA LOUIE, AICP | | | PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1442 | | | EMAIL: [email protected] | | | | | | |
|
|
|