Plan Review Details - Permit 13080440
Plan Review Stops For Permit 13080440
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-10-21 Cont ID  
Sent By jwitmer Date 2013-10-03 Time 09:03 Rev Time 0.00
Received By jwitmer Date 2013-10-03 Time 09:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2013-08-21 Cont ID  
Sent By jwitmer Date 2013-08-21 Time 12:57 Rev Time 0.00
Received By jwitmer Date 2013-08-21 Time 12:26 Sent To  
Notes
2013-08-21 12:57:15BUILDING PLAN REVIEW
 PERMIT: 13080440
 ADD: 301 53RD ST UNIT A
 CONT: BESA CONSTRUCTION
 TEL: (561)605-3399
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: AUGUST 21/ 2013
 ACTION: DENIED
  
 1) CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE
 FLORIDA BUILDING CODE 2010 CHAPTER 1 ADMINISTRATION
 107.1 WHO EVER THE DESIGNER IS FOR THE BUILDING SET OF
 PLANS WILL NEED TO PRINT, SIGN THEIR NAME AND LICENSE
 NUMBER ON THE PLANS, FOR EACH OF THE TRADES. THE CGC
 CAN ONLY DESIGN THE BUILDING PORTTION OF PLANS, AND
 THEY HAVE TO ALSO BE THE ONES TO COMPLETE THE WORK
 UNDER THE PERMIT, THIS GOES FOR EACH OF THE TRADES
 INVOLED.
  
 2) THE PLANS DO NOT PROVIDE WHAT THE UNIT LOOKED LIKE
 BEFORE THE REMODEL, WE ARE UNABLE TO KNOW WHAT IS
 EXISTING AND WHAT IS NEW. PLEASE PROVIDE EXISTING AND
 PROPOSED FLOOR PLANS. CITY OF WEST PALM BEACH LOCAL
 AMENDMENTS TO THE FLORIDA BUILDING CODE 2010 CHAPTER 1
 ADMINISTRATION 107.2.1 CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES.
  
 3) PLEASE IDENTIFY IF THIS UNIT IS A TOWNHOUSE UNIT OR
 IS THIS A TOWNHOUSE UNIT, IT WILL DETERMINE TO WHICH
 CODE BOOK WE CONDUCT OUR REVIEW.
 CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2010 CHAPTER 1 ADMINISTRATION 107.2.1.3
 ADDITIONAL INFORMATION IS REQUIED.
  
 4) THE PLANS INDICATE WHAT APPEARS TO BE A DOOR OPENING
 TO THE EXTERIOR FROM THE RENOVATED BATHROOM, IS THIS A
 NEW OPENING, IF SO PLEASE PROVIDE THE TYPE OF EXTERIOR
 WALLS ARE BEING CONSTRUCTEDPROVIDE FINSHES AND PRODUCT
 APPROVALS FOR THE NEW DOOR OPENING. 107.2.1.3
 ADDITIONAL INFORMATION IS REQUIRED.
  
 5) PLANS APPEAR THAT PARTS OF THE BATHROOM FLOOR WILL
 BE REMOVED FOR THE NEW PLUMBING WASTE PIPING. PLEASE
 PROVIDE HOW THE FLOOR SLAB IS GOING TO BE REPAIRED IF
 IT IS A CONCRETE SLAB. 107.2.1.3 ADDITIONAL INFORMATION
 IS REQUIRED. PLEASE PROVIDE DETAILS FOR COMPLIANCE
 WITH:
 5A) 2010 FBC 1816.1.4
 IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE
 PREVENTION, CHEMICALLY TREATED SOIL SHALL BE PROTECTED
 WITH A MINIMUM 6 MILLIMETER VAPOR RETARDER TO PROTECT
 AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE
 VAPOR RETARDER PLACEMENT, RETREATMENT IS REQUIRED. ANY
 WORK, INCLUDING PLACEMENT OF REINFORCING STEEL, DONE
 AFTER CHEMICAL TREATMENT UNTIL THE CONCRETE FLOOR IS
 POURED, SHALL BE DONE IN SUCH MANNER AS TO AVOID
 PENETRATING OR DISTURBING TREATED SOIL.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-10-15 Cont ID  
Sent By dharvey Date 2013-10-15 Time 16:07 Rev Time 0.00
Received By dharvey Date 2013-10-15 Time 15:25 Sent To  
Notes
2013-10-15 16:16:16I CALLED AND SPOKE W/MR. LOU BESA OF BESA CONSTRUCTION
 TO DISCUSS THE MISSING ITEMS ON THE SUBMITTED DRAWING.
 HE ASSURED ME THAT ELECTRICAL COMPLIANCE WILL BE MET BY
 HIS ELECTRICAL CONTRACTOR FOR ALL INSPECTIONS. I
 MENTIONED THE MINIMUM CLEARANCE REQUIREMENTS OF NEC
 110.26, AS WELL AS THOSE OF 110.34(B) DUE TO THE AIR
 HANDLER BEING IN THE ATTIC. I ALSO MENTIONED THE NEED
 FOR CO DETECTOR AND S/DETECTOR COMPLIANCE. FURTHERMORE,
 THERE IS AN ISSUE OF A DIVIDING WALL BETWEEN THE FAMILY
 ROOM AND THE PROPOSED KITCHENETTE. THE OWNER IS
 UNCERTAIN IF IT WILL REMAIN OR BE REMOVED. THE OUTLET
 REQUIREMENTS OF 210.57 WERE ADDRESSED. RETURNED TO B27
 BY MA

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2013-09-04 Cont ID  
Sent By dharvey Date 2013-09-04 Time 18:54 Rev Time 0.00
Received By dharvey Date 2013-09-04 Time 18:54 Sent To  
Notes
2013-09-04 18:55:50FIRST REVIEW - 9-4-13
 1. PROVIDE A PANEL SCHEDULE AND SHOW LOCATION ON FLOOR
 PLAN
 2. SHOW CIRCUITRY ON ELECTRIC FLOOR PLAN
 3. ARE THERE ANY RECEPTS BEING INSTALLED? PLEASE SHOW
 THEM
 END OF REVIEW VB

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2013-08-17 Cont ID  
Sent By wjolin Date 2013-08-17 Time 19:13 Rev Time 0.00
Received By wjolin Date 2013-08-17 Time 19:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-10-19 Cont ID  
Sent By jwitmer Date 2013-10-19 Time 09:04 Rev Time 0.00
Received By jwitmer Date 2013-09-11 Time 16:29 Sent To  
Notes
2013-09-12 16:29:57SENT TO B9 SHELF FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2013-09-09 Cont ID  
Sent By hmoser Date 2013-09-09 Time 14:20 Rev Time 0.00
Received By hmoser Date 2013-08-13 Time 14:29 Sent To  
Notes
2013-08-14 14:29:56SENT TO B27 SHELF FOR REVIEW. JG.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2013-10-04 Cont ID  
Sent By hmoser Date 2013-10-04 Time 14:03 Rev Time 0.00
Received By hmoser Date 2013-10-04 Time 14:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2013-09-09 Cont ID  
Sent By hmoser Date 2013-09-09 Time 14:02 Rev Time 0.00
Received By hmoser Date 2013-09-09 Time 14:02 Sent To  
Notes
2013-09-09 14:20:13PROVIDE ENERGY HEAT LOADS PER SECTION 403.6 HEATING AND
 COOLING EQUIPMENT (MANDATORY)
 2010 FLORIDA ENERGY CODE .
 PROVIDE A CHANGE OUT FORM WITH HEAT LOADS.
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 2 Status P Date 2013-09-17 Cont ID  
Sent By lwagner Date 2013-09-17 Time 09:00 Rev Time 0.00
Received By lwagner Date 2013-09-17 Time 08:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2013-08-16 Cont ID  
Sent By lwagner Date 2013-08-16 Time 10:23 Rev Time 0.00
Received By lwagner Date 2013-08-16 Time 10:16 Sent To  
Notes
2013-08-16 10:23:12FBC 2010 EXISTING BUILDING CODE
 FBC 2010 PLUMBING REVIEW #1
 DENIED:
  
 THE KITCHEN SINK IS SHOWN WET VENTING THE WATER CLOSET
 AND SHOWER.
 909.1 HORIZONTAL WET VENT PERMITTED.
 ANY COMBINATION OF FIXTURES WITHIN TWO BATHROOM GROUPS
 LOCATED ON THE SAME FLOOR LEVEL IS PERMITTED TO BE
 VENTED BY A HORIZONTAL WET VENT. THE WET VENT SHALL BE
 CONSIDERED THE VENT FOR THE FIXTURES AND SHALL EXTEND
 FROM THE CONNECTION OF THE DRY VENT ALONG THE DIRECTION
 OF THE FLOW IN THE DRAIN PIPE TO THE MOST DOWNSTREAM
 FIXTURE DRAIN CONNECTION TO THE HORIZONTAL BRANCH
 DRAIN. EACH WET-VENTED FIXTURE DRAIN SHALL CONNECT
 INDEPENDENTLY TO THE HORIZONTAL WET VENT. ONLY THE
 FIXTURES WITHIN THE BATHROOM GROUPS SHALL CONNECT TO
 THE WET-VENTED HORIZONTAL BRANCH DRAIN. ANY ADDITIONAL
 FIXTURES SHALL DISCHARGE DOWNSTREAM OF THE HORIZONTAL
 WET VENT.
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  

Review Stop Z ZONING
Rev No 1 Status P Date 2013-08-23 Cont ID  
Sent By avann Date 2013-08-23 Time 14:19 Rev Time 0.00
Received By ajones Date 2013-08-23 Time 14:19 Sent To  
Notes
2013-08-21 15:26:528/21/13